LavryBlue 4496
Operation
3
B.) M•SYNC OPERATION
INTERNAL CLOCK OPERATION:
Set the right-hand switch on LavryBlue M•SYNC to “INT.”
The Narrow/Wide switch has no effect when the M•SYNC is set to “Internal” operation.
The “Lock" lamp does not illuminate during Internal Clock operation.
The 2 left switches set the sample frequency for Internal Clock and External Clock Narrow Mode.
The HIGH/LOW switch is set to High for 88.2 and 96 kHz, and to Low for 44.1 and 48 kHz.
SAMPLE RATE SWITCH POSITIONS:
Sample Rate-indicated by LED
48/96 - 44/88 Switch
High – Low Switch
44.1 kHz
Down
Down
48 kHz
Up
Down
88.2 kHz
Down
Up
96 kHz
Up
Up
EXTERNAL CLOCK OPERATION:
Set the right-hand switch to “WRD CLK” or “AES.”
The unit locks to a signal applied to the rear panel BNC connector labeled “SYNC IN.”
-WRD CLK locks the M•SYNC to incoming word clock. When lock is achieved, it is indicated
by the LOCK lamp illuminating.
-AES locks the M•SYNC to an incoming AES signal. When lock is achieved, it is indicated by the
LOCK lamp illuminating.
The use of “AES BLACK” for AES Sync is recommended, whenever possible. This is an AES
signal with all of the audio data set to “0” or in other words “Mute.”
Setting the WIDE/NARROW switch to NARROW provides a +/- 150 PPM lock range. Use this setting
for standard sample rates: 44.1, 48, 88.2, & 96 kHz. In Narrow mode, the incoming Sync signal’s sample
rate MUST MATCH the settings of the M•SYNC to “Lock” (see Sample Rate Switch Positions- above, and
2X Switch- below).
Setting the WIDE/NARROW switch to WIDE and the HIGH/LOW switch to LOW provides external
clock operation in the 42-50 kHz range.
Setting the WIDE/NARROW switch to WIDE, and the HIGH/LOW switch to HIGH provides external
clock operation in the 84-100 kHz range. The rear panel 2X switch must be “OFF” for this configuration.
-When in NARROW lock, one frequency indicator lamp shows the selected output rate.
-When in WIDE lock and LOW, the top lamps (44.1 and 48 kHz) are lit simultaneously to
indicate 42-50 kHz range.
-When in WIDE lock and HIGH, the bottom lamps (88.2 and 96KHz) are lit simultaneously to
indicate 84-100 kHz range.