The Front Panel
6
M
ONITOR
O
UT
This pair of XLR connectors replicates the Main Out signals with user adjustable attenuation, controlled via
the front panel Volume control.
B
ALANCED
/
U
NBALANCED
S
WITCHES
Each of the output pairs has its own switch for balanced or unbalanced settings. When set to the unbalanced
position, pin 2 of the XLR output is hot and pin 3 is grounded.
G
AIN
R
ANGE
S
WITCHES
Each of the output pairs has its own gain Range switch. The gain range lowers the signal level by 6dB in
either balanced or unbalanced operation.
The Lavry Quintessence front panel has a simple user interface which consists of 6 LEDs, 8 illuminated
pushbuttons, a 4 digit segmented numerical LED display, and one rotary knob with a built-in pushbutton
switch. A pushbutton which is illuminated in green indicates an enabled setting. A pushbutton
illuminated in blue indicates a setting which is disabled.
Figure 2- Front Panel Layout
1. Sample Rate Indicator LEDs
2. Invert On/Off
3. Mono On/Off
4. Calibration
5. Input 1 Select
6. Input 2 Select
7. Input 3 Select
8. Main Output Enable
9. Monitor Output Enable
10. Level Display
11. Rotary Knob & Pushbutton
S
AMPLE
R
ATE
I
NDICATOR
LED
S
When the unit is locked to a digital audio input signal, one of these six LEDs will be illuminated, indicating the
sample rate. This Quintessence can accommodate sample rates of 44.1, 48, 88.2, 96, 176.4, and 192 kHz.
When the unit is not receiving a valid digital audio input signal, the LEDs will strobe in a repeated pattern.