LCG BEAMER 6 User Manual

Manual is about: 12x 12W-RGBAWU 6-in-1

Summary of BEAMER 6

  • Page 1

    Www.Lc-group.Ca user manual beamer 6 lcg-1212s (12x 12w-rgbawu 6-in-1).

  • Page 2: Catalogue

    Www.Lc-group.Ca catalogue 1. Summary ................................................................................................................ 1 2. Safety instruction ................................................................................................... 2 3. Outside size picture ...

  • Page 3: Summary

    Www.Lc-group.Ca 1 1. Summary summary thank you for purchasing our beamer 6 . Please read these instructions carefully before begin and operate the fixtures according to these instructions to avoid any possible damages and accidents causes by misusage  product introduction beamer 6 light uses castin...

  • Page 4: 2. Safety Instruction

    Www.Lc-group.Ca 2 2. Safety instruction  safety notes ! Enquire the skilled people before any repair; ! Always make sure disconnect from the power source before setting up, serving and moving;. ! Avoid direct eye exposure to the fixture when it is on; safety instruction ● make sure the power supply...

  • Page 5: 3. Outside Size Picture

    Www.Lc-group.Ca 3 3. Outside size picture.

  • Page 6: 4. Main Function

    Www.Lc-group.Ca 4 4. Main function  input voltage: ac 100v-264v/47-63hz  consume:150w  lamp type:12w led 6-in-1 r、g、b、a、w、uv (12pcs)  life span: 50000~100000hours  pwm dimmer:1500hz(16666 grades)  control signal:dmx512  control mode:stand alone/ sound activated  channel:12ch、9ch、7ch、6ch、5ch、...

  • Page 7: 5. Dmx Control Function

    Www.Lc-group.Ca 5 5. Dmx control function  dmx channels 4ch 5ch 6ch 7ch 9ch 12ch value function - ch1 - ch1 ch1 ch1 0-255 dimming all ch1 - ch1 ch2 ch2 ch2 0-255 red ch2 - ch2 ch3 ch3 ch3 0-255 green ch3 - ch3 ch4 ch4 ch4 0-255 blue - ch2 ch4 ch5 ch5 ch5 0-255 amber ch4 ch3 ch5 ch6 ch6 ch6 0-255 wh...

  • Page 8

    Www.Lc-group.Ca 6 91-95 chase 2 96-100 chase 3 101-110 reserved 111-200 r:111-115,g:116-120,b:121-125,a:126-130,w:1 31-135,uv:136-140,yellow:141-145,pink:1 46-150,cyan:151-155,orange:156-160,vio let:161-165,golden:166-170,2700k:171-175 ,3200k:176-180,4000k:181-185,5500k:186-190, 6500k:191-195,rgbw:1...

  • Page 9: Menu Tree

    Www.Lc-group.Ca 7 6. Display operation instruction  menu : access the menu or return to a previous menu option  enter: select the current menu option  up: menu selection or parameter increments  down: menu selection or parameters decrease menu tree tab level 1 level 2 level 3 level 4 addr(addres...

  • Page 10

    Www.Lc-group.Ca 8 mode) 9ch 7ch 6ch 5ch 4ch dim(dimming mode) lin/sqr/isqr/scur/lin. /sqr./isqr/scur. Disy(display set) on(permanent on) 2min (2 minutes off) lock(key 2 minutes lock) yes/no ctst(custom color set) ct01 r(red) 0-255 . G(green) 0-255 . B(blue) 0-255 . A 0-255 . W 0-255 . Uv 0-255 ct10 ...

  • Page 11

    Www.Lc-group.Ca 9 chs3(chase 3) info (information) soft(software version) vx.X pow(power reduction) 100%/80%/50% load(load) st l(setting load) yes/no pr l(program load) yes/no send(send) yes/no instructions: when enter to the “*” position displayed on the led, the light will automatically set as mas...

  • Page 12

    Www.Lc-group.Ca 10 4) on the【use】interface, pressing【yes】button means valid,【no】means invalid. 5) press the【enter】button to escape and save. Illustrations: when pressing the【yes】button which means valid on the【use】interface, the actual output value of red,green,blue,amber,white, uv is output in acco...

  • Page 13

    Www.Lc-group.Ca 11 2) press the【up/down】button to select【yes】,【no】 3) press the【enter】button to escape and save. Instructions: when set to [yes], it will lock automatically after two minutes to prevent accidental triggering flood flushing, and then press any key for 10 seconds to unlock.Sametimes it...

  • Page 14

    Www.Lc-group.Ca 12 6.11 check the lighting information 1) press the【enter】button in【info】menu, then enter to the checking the lighting information. 2) 【soft】button is for software version information. 3) 【pow】button is for the current information of power reduction. It is 100% output in normal condi...

  • Page 15: 8. Xlr Cable Connecting

    Www.Lc-group.Ca 13 7. Operating control instruction master/slave when the fixtures work in master mode it will send out the signal for the slave synchronous with it. To avoid the host signal and dmx512 signals interfere with each other, should cut off the dmx512 signals. The signal lines are longer ...

  • Page 16: 9. Connecting Picture

    Www.Lc-group.Ca 14 9. Connecting picture light connecting picture :.

  • Page 17: 10. Trouble Shooting

    Www.Lc-group.Ca 15 10. Trouble shooting problem reason and action the lightin g can’t be started normally  check the power connection is correct or not.  please detect the voltage.  power supply is damaged or incorrect connected. Call a qualified personnel to fix it.  connection of control board...

  • Page 18

    Www.Lc-group.Ca 16.