    75.5319.00 20080111 page 1 of 9 description specification frequency: 24.125 ghz supply voltage: 12 to 24 v ac: ± 10%: 12 to 24 v dc: -10% / +30%: mounting height: normal: 7’; maximum: 10’-0” tilt angle: 0 to 90 vertical -15 to +15 lateral detection area: wide narrow 13ft (w) x 6.5ft (d) 6.5ft (w) x ...

  • Page 2: 3 Installation

    75.5319.00 20080111 page 2 of 9 1 tips 2 safety precautions • shut off all power going to the header before attempting any wiring procedures. • maintain a clean & safe environment when working in public areas. • constantly be aware of pedestrian traffic around the door area. • always stop pedestrian...

  • Page 3

    75.5319.00 20080111 page 3 of 9 3 mechanical installation opening the microwave motion sensor (mss) ‰ from behind, before installation ‰ from the front, after installation mounting the mms ‰ paste the template at desired location. ‰ insert screws but do not screw them fully in. ‰ optional cable rout...

  • Page 4

    75.5319.00 20080111 page 4 of 9 5 mechanical adjustments a. The width of the sensing field is determined by the choice of the planar antenna (option) wide sensing field: 3-element antenna narrow sensing field: 6-element antenna sensing fields according to the type of antenna the sensing fields above...

  • Page 5

    75.5319.00 20080111 page 5 of 9 c. The lateral position of the sensing field in front of the door is determined by the lateral tilt angle of the antenna. The sensing fields on the right correspond to following adjustments: wide sensing field antenna lateral angle of the antenna: +30°, -30° sensitivi...

  • Page 6

    75.5319.00 20080111 page 6 of 9 6 programming guide the microwave motion sensor (mms) is equipped with a motion tracking feature (mtf). The mtf is available when the sensor is used in the uni-directional mode. The mms is factory preset with the mtf on. Mtf is recommended for use in short vest bule a...

  • Page 7

    75.5319.00 20080111 page 7 of 9 7 manual setup if a remote control is not available, only the sensitivity parameter can be adjusted manually, by means of the push buttons + (plus) and - (minus). The sensor parameters that are not accessible manually will remain at the factory preset values. Pressing...

  • Page 8: 4 Troubleshooting

    75.5319.00 20080111 page 8 of 9 symptoms probable cause corrective action the sensor power is off. Check the wiring and power supply. The door will not open and no red led lights up. The door control is set to level 3. Set door control to automatic mode (level 1). The door opens and closes constantl...

  • Page 9: Appendix – Wiring Diagrams

    75.5319.00 20080111 page 9 of 9 appendix – wiring diagrams.