Le Cappe WALL MOUNT HOODS Instructions Manual And User Manual

Summary of WALL MOUNT HOODS

  • Page 1

    Instructions guide and user manual wall mount hoods. Important: read and save these instructions. Notice: installer: leave this guide with the homeowner homeowner: keep this guide for future reference.

  • Page 2: Important Safety Notice

    • the installation in this manual is intended for qualified installers, service technicians or persons with similar qualified background. Installation and electrical wiring must be done by qualified professionals and in accor- dance with all applicable codes and standards, including fire-rated const...

  • Page 3: Important Safety Notice

    To reduce the risk of injury to persons in the event of a stove top grease fire: • smother flames with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. Be careful to prevent burns. Never pick up a flaming pan—you may be burned. Keep flam- mable or combustible material away...

  • Page 4: Table of Content

    Table of content tools needed: installation tools needed. 3 parts supplied. 4 venting requirements. 5 mount heights & clearance. 5-6 venting methods & re-calculating functions 7 charcoal filter installation 8 electrical requierements 8 preparations 9 installation 10 use and care range hood operation...

  • Page 5: Parts Supplied:

    Parts supplied: range hood (vary by model) lower standard chimney main unit upper standard chimney a qty: 2pcs d qty: 4pcs b qty: 1pcs c qty: 1pcs air diverter (optional re-circulating kit, pre-installed when ordered together with range hood) charcoal filter (optional re-circulating kit, pre-install...

  • Page 6: Venting Requirements

    Venting requirements height & clearance • vent system must terminate to the outside (roof or side wall). • do not terminate the vent system in an at- tic or other enclosed area. • do not use 4” (10.2 cm) laundry-type wall caps. • use metal /aluminum vent only. Rigid metal (not included). Aluminum ve...

  • Page 7: Important

    Important • a minimum of 6” round (standard for this range hood) or 3-1/4 x 10” rectangular duct (purchased sepa- rately) must be used to maintain maximum airflow efficiency. • flexible 6” round duct, always use rigid type metal/aluminum ducts if available to maximize airflow when connecting to prov...

  • Page 8

    Venting methods: re-circulating function methods: this range hood is factory set for venting through the roof or wall. • vent work can terminate either through the roof or wall. To vent through a wall, a 90° elbow is needed. Important: • never exhaust air or terminate duct work into spaces between w...

  • Page 9: Charcoal Filter Installation

    Charcoal filter installation electrical requirements note: the charcoal filter or filters are required when using the lecappe hood as a purifying unit only if you purchased the range hood with re-circulating kit from us. 1. Remove aluminum filters on hood. 2. Position the charcoal filter or filters ...

  • Page 10

    Preparations note: to avoid damage to your hood, prevent debris from entering the vent opening. 1. Carefully remove the white plastic protective coat from the chimney covers and range hood 2. Determine and mark the center line on the ceiling where the range hood will be installed. Make sure there is...

  • Page 11: Installation

    Installation • vent system must terminate to the outside (roof or side wall). • do not terminate the vent system in an at- tic or other enclosed area. • do not use 4” (10.2 cm) laundry-type wall caps. • use metal /aluminum vent only. Rigid metal (not included). Aluminum vent is recommended. • do not...

  • Page 12

    Control panel layout and buttons configurations for models: grecia, paris, venice pro. Range hood opeations & controls range hood operations controls 11.

  • Page 13

    Control panel layout and buttons configurations for models: moon & viena. Range hood operations controls 12.

  • Page 14

    Control panel layout and buttons configurations for models: messina & athenas (see your specific model) range hood operations controls 13.

  • Page 15: Troubleshooting

    Troubleshooting 1. If the range hood or halogen light does not operate after installation: 2. The range hood vibrates when the blower is on: 3. The blower or fan seems weak: 4. The lights work but the blower is not spinning at all, is stuck or is rattling. 5. The hood is not venting out properly: • ...

  • Page 16: Use and Care Information

    Use and care information specifications operations: • read and understand all instructions and warnings in this manual before operating the appliance. Save theseinstructions for future reference. • always leave safety grills and filters in place. Without these components, operating blowers could cat...

  • Page 17: Specifications

    Specifications for optimal operation, clean range hood and all baffle/spacer/filter/grease tunnel/oil container regularly. Regular care will help preserve the appearance of the range hood. Cleaning exterior surfaces: • clean periodically with hot soapy water and clean cotton cloth. Do not use corros...

  • Page 18: Changing The Light Bulb

    Cleaning aluminum grease filter / stainless steel filter less grill changing the light bulb warning • failure to observe the instructions on cleaning the unit and changing the filters could cause a fire hazard. You are therefore strongly recommended to follow these instructions. • the manufacturer d...

  • Page 19

    Le cappe one year limited warranty: please provide an original dated proof of purchase (sales receipt / invoice) in order to obtain service under warranty. One year parts warranty: for one year from the date of original purchase, your local reseller will provide free of charge, non- consumable repla...