Leadway LDW-TKV103B User Manual - page 7
7
10)Over speed alarm setup
Command
Format
Example
Set over speed alarm
SSA#120#mode#
1) SSA#120#
2) SSA#150#3#
Cancel alarm
CSA#
CSA#
Setup alram interval time
STIME#time#
STIME#5#
Command notes
The speed in 60~220,Default is close. Mode: from 1 to 3.
1 is SMS, 2 is phone call, 3 is sms and phone call both ways.
When you cancel the over speed alarm and you want to open it
again and you should set it again.
Alarm interval time:Default time is 5miniutes , range: 1~60
miniutes, it’s mean every 5 mins will upload one alarm
SMS feedback
Over speed alarm sertup sucess!alarm mode is sms or phone call
Over speed alarm interval time setup success.
Cancel over speed alarm sucess!
11)Timezone setup
Command
Format
Example
Set timezone
801#timezone#
801#E8#
Command notes
E is East timezone,W is west timezone,E8 it’s mean East
timezone 8,W8 it’s mean West timezone 8.
Command feedback
Timezone setup success!
12)Restart
Command
Format
Example
Restart the device
930#
930#
Command notes
It’s use for restart the device
SMS feedback
The device will be restart soon!
13)Language setup
Command
Foramt
Example
Setup language
LANG number#
1) LANG1#
2) LANG0#
Command notes
1 is Chinese, and 0 is english. Default language is Chinese.
SMS feedback
Language setup success!
14)Set interval time under movement
Command
Format
Example
Interval time setup
730#time#
730#20#
Command notes
This command use for set the inerval time when the vehicle is
moving.
time:in the range of 10~60s
default time is 15s
SMS feedback
Movement interval time setup success!
15)Set interval time under static
Command
Format
Example
Static interval time setup
SUP#time#
SUP#5#
Command notes
This command use for set the inerval time when the vehicle is
static.
Time:in 1~60miniutes
Default time is 5 miniutes
SMS feedback
Static interval time setup success!