Legacy (F) User's Operation And Installation Manual

Manual is about: Unvented Gas-Fired Room Heater

Summary of (F)

  • Page 1

    Installer / consumer safety information please read this manual before installing and using the heater. Warning: if the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. • do not store or use gasoline or other...

  • Page 2: General Information

    2 general information safety: accidents are always tragic especially because so many of them could have been prevented with a little care and attention. These are some basic good practices we hope you will follow for safe use of your gas fired room heater. Important: read this user's manual carefull...

  • Page 3

    3 rmc-lcng, rmc-lclp, rmc-ling, rmc-lilp specifications models (manual & thermostat) gas type input rating (btu/hr) variable regulator pressure setting inlet gas supply pressure size of heater weight min. Max min. Max rmc-lc30ng natural 15,000 30,000 4.0” w.C. 5.0” w.C. 11” w.C. 27”x 24”x8 1/2 ” 30 ...

  • Page 4: Installation

    4 installation • this heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air. • this heater must have fresh air for proper operation. If not, poor fuel combustion could result. Read the following in...

  • Page 5

    Locating the heater 5 preparing for installation 1. Remove heater from carton 2. Remove all protective packaging applied to heater for shipment. 3. Check heater for any shipping damage. If heater is damaged, promptly inform dealer/distributor. 4. Select a location for the heater that will provide ma...

  • Page 6

    6 floor installation 1. Heater may only be installed on a noncombustible flat surface. Where the flooring is carpeting, tile or of other combustible material other than wood flooring, maintain the minimum clearances to the floor as shown in figure 2 or else use a metal or wood panel (not supplied) e...

  • Page 7

    7 installation should be done by a qualified service person. Before connecting the appliance, turn off all gas appliances. Close the main gas valve at the gas meter or lp tank. Make certain there is good ventilation where the installation will be made. Installation should comply with all applicable ...

  • Page 8: Operation Instructions

    8 operation instructions for your safety - read this section before lighting a. Before lighting smell all around the appliance area for gas. Be sure to smell next to floor because some gas is heavier than air and will settle on the floor. Lighting instructions warning: if you do not follow these ins...

  • Page 9

    9 turning heater off push in gas control knob slightly and turn clockwise to "off" position. Do not force. Turning burner only off (pilot stays lit). Turn control knob clockwise to the pilot position. Caution: do not try to adjust heating levels by using the manual shut-off valve. Note: the thermost...

  • Page 10: Troubleshooting

    10 problem possible cause what to do when control knob is pressed in and turned counterclockwise to ignition, there is no spark at ods pilot. 1. Ignitor electrode positioned wrong. 2. Ignitor electrode broken. 3. Ignitor cable pinched or broken. 4. Ignitor cable not connected to ignitor electrode. 1...

  • Page 11: Maintenance

    11 problem possible cause what to do heater produces a clicking noise just after burner is lit or turned off. 1. Metal expanding and contracting. 1. This is common with heaters. If noise is excessive, contact a qualified service technician. Gas odor even when control knob is in off position. 1. Gas ...

  • Page 12

    12 item/model number rmc-li06ng/lp rmc-li10ng(t)/lp(t) rmc-li18ng(t)/lp(t) rmc-li30ng(t)/lp(t) 1. Lower heat cover li10lp-01-01-02 li10lp-01-01-02 li18lpt-01-01-03 li30ng-01-01-02 2. Guard assembly lc10ng-01-04 lc10ng-01-04 li18lpt-01-04 lc30ngtf-01-04 3. Reflector li10lp-01-01-01 li10lp-01-01-01 li...

  • Page 13

    13 cfm home products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. Warning: failure to position the parts in accordance with this diagram or failure to use only parts specifically approved with this he...

  • Page 14: Accessories

    14 the following accessories are available from your local distributors/dealer. Each accessory comes with a separate installation instruction. Be sure to read each instruction thoroughly before installation. Accessories operation & maintenance instructions fma-(f,ft) manually & thermostatically cont...

  • Page 15

    15 accessories continued caution: damaged power cord can cause a fire or electric shock. Prior to installing the blower, check for blower for any shipping damage. If blower is damaged, promptly inform dealer where you bought the blower. Installation: plug the blower power cord into a 110-120v proper...

  • Page 16

    Service and limited warranty cfm home products warrants this product to be free from defects in materials and components for three (3) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions....