Legacy Stoves TLC 2000 Installation & Operating Manual

Other manuals for TLC 2000: Installation And Operating Manual
Manual is about: Coal Stove

Summary of TLC 2000

  • Page 1

    3-90-08691r18_12/13 rev 140912 safety notice please read this entire manual before you install and use your new room heater. Failure to follow instructions may result in property damage, bodily injury, or even death. For use in the u.S. And canada. Do not install in a mobile home. If this stove is n...

  • Page 3: Sample

    3-90-08691r18_12/13 rev 140912 report #/ rapport # 135-s-28-4 tested to / testé à: ul 1482-201 1, ul 737-201 1, and ulc-s627-00 do not inst all in a mobile home this appliance is approved for installation into a shop. “prevent house fires” install and use only in accordance with manufactu rer ’s ins...

  • Page 4: Introduction

    4 3-90-08691r18_12/13 rev 140912 2393 little egypt rd harrisonville, pa 17228 introduction please read this entire manual before you install and use your new room heater. Failure to follow instructions may result in property damage, bodily injury, or even death. Note: this appliance is also approved...

  • Page 5

    3-90-08691r18_12/13 never sleep in the same room with any coal burning stove carbon monoxide (co) awareness carbon monoxide, referred to as co, is a colorless, odorless gas that is produced during combustion of coal and other fuels. Co fumes are toxic and can be fatal. The tlc 2000 is a natural draf...

  • Page 6: Specifications

    6 3-90-08691r18_12/13 specifications weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 462 lbs flue size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 inch fuel: usa: pea, nut, or stove coal, cordwood with optional spark screen canada:...

  • Page 7: Unit Overview

    7 3-90-08691r18_12/13 top load door top load door arm side shield ash door latch ash door coal air control front load door handle top load opening glass door grates (2) wood air control removable shaker handle clean-out cover coal bars (3) unit overview.

  • Page 8: Operation

    8 3-90-08691r18_12/13 rev 140912 operation the stove doors your stove has a large glass-paneled door for loading and fire viewing, a separate smaller door for removing ashes and a top loading door. To open the glass door, turn the handle clockwise and pull out; to close the door, return the handle t...

  • Page 9

    9 3-90-08691r18_12/13 air controls coal the primary air control for coal burning is a knob located on the bottom door. Sliding the knob to the left provides less air for a smaller fire. Sliding the knob to the right provides more air for a larger fire. When burning wood, this knob should be all the ...

  • Page 10

    10 3-90-08691r18_12/13 remove cleanout plate to burn as a fireplace stove ashes should be placed in a steel container with a tight fitting lid and moved outdoors immediately. The closed container of ashes should be placed on a noncombustible floor or on the ground, well away from all combustible mat...

  • Page 11

    11 3-90-08691r18_12/13 1. Grates 4. Fresh coal 2. Ashes on grates 5. Ashes in ash pan 3. Partly burned coal 6. Grate bars 2 3 5 1 4 6 building and maintaining a coal fire; build a wood fire as described but instead of adding larger wood, limit the size to about 2" in diameter. Add enough 2" wood tha...

  • Page 12

    12 3-90-08691r18_12/13 cooking grill handle handle ash pan disposal of ashes. The tlc 2000 was designed to provide access to the ash pan without the need for opening the main door. Wearing heavy protective gloves, open the ash door and remove the ash pan by pulling it forward by the handle. Close th...

  • Page 13: Maintenance

    13 3-90-08691r18_12/13 like all fine equipment, your tlc 2000 requires some routine maintenance and inspection. Follow the guidelines in this section to guarantee safe, efficient operation. The stove surface the stove’s exterior surface should be dusted periodically with a soft cloth. For more thoro...

  • Page 14: Maintenance

    14 3-90-08691r18_12/13 glass - cleaning sometimes it will be necessary to clean accumulated ash from the glass surface; allowing this ash to remain on the glass for long periods can result in “etching” due to the acidity of the ash. The creosote which accumulates on the glass should burn off during ...

  • Page 15: Installation

    15 3-90-08691r18_12/13 installation do not install in a sleeping room assembly blower (optional) bolt the blower to the bottom rear of the stove with four 1/4-20 bolts. Tighten the bolts, but do not overtighten. The blower speed can be adjusted using the knob that is built-in to the power cord. When...

  • Page 16: Installation

    16 3-90-08691r18_12/13 rev 140912 floor protection in all installations, the area under and around the stove must be protected from falling ash and live coals. The floor protector must be of noncombustible material, and positioned as shown in the accompanying illustration. The guidelines for floor p...

  • Page 17: Chimney System

    17 3-90-08691r18_12/13 the chimney system soot and creosote - formation and need for removal when wood is burned slowly, it produces tar and other organic vapors, which combine with expelled moisture to form soot or creosote. The soot and creosote vapors condense in the relatively cool chimney flue ...

  • Page 18: Chimney System

    18 3-90-08691r18_12/13 the nfpa (national fire protection association) permits four methods for passing through a combustible wall. A commonly used method to pass through a wall directly to a masonry chimney is to clear a minimum 12"(300 mm) around the entire chimney connector, and fill it with bric...

  • Page 19: Chimney System

    19 3-90-08691r18_12/13 rev 140912 installing to a prefabricated chimney when venting your tlc 2000 using a prefabricated chimney, be sure to contact local building code authorities, and to follow the manufacturer’s instructions exactly. Use only the manufacturer’s parts; do not use makeshift install...

  • Page 20: Tlc-2000

    Service parts beginning manufacturing date: n/a ending manufacturing date: active tlc-2000 part number list on following page. Top load coal/wood stove 1-70-08690-4 (metallic blue) ending manufacturing date jan 2010 1-70-08690-5 (honey glo) ending manufacturing date june 2009 1-70-08690-10 (mojave r...

  • Page 21: Tlc-2000

    Service parts beginning manufacturing date: n/a ending manufacturing date: active tlc-2000 important: this is dated information . Parts must be ordered from a dealer or distributor. Provide model number and serial number when requesting service parts from your dealer or distributor. Stocked at depot...

  • Page 22: Tlc-2000

    Service parts beginning manufacturing date: n/a ending manufacturing date: active tlc-2000 important: this is dated information . Parts must be ordered from a dealer or distributor. Provide model number and serial number when requesting service parts from your dealer or distributor. Stocked at depot...

  • Page 23

    4021-645f 02-18-13 page 1 of 2 alternate heating systems limited lifetime warranty alternate heating systems, on behalf of its hearth brands (”ahs”), extends the following warranty for ahs gas, wood, pellet, coal and electric hearth appliances that are purchased from an ahs authorized dealer. Warran...

  • Page 24

    3-90-08691r18_12/13 4021-645f 02-18-13 rev 140912 page 2 of 2 warranty conditions: • this warranty only covers ahs appliances that are purchased through an ahs authorized dealer or distributor. A list of ahs authorized dealers is available on the ahs branded websites. • this warranty is only valid w...

  • Page 25: Service & Maintenance Log

    25 service & maintenance log date of service performed by description of service 3-90-08691r18_12/13.

  • Page 26

    Legacy stoves tm - advanced design & old fashioned values (signature of boxer) your premium quality hearth product designed and assembled by the experienced and skilled members at legacy stoves tm in harrisonville, pa, usa..