Using the Reset Button
To reboot the Monarch, use a straightened paper clip or similar device to
momentarily depress the tiny RESET pin on the front panel for
about 2 minutes for the recorder to reboot. *** Note that the RESET logo is the
circular one with the arrow. The Reset pinhole is just above it.
In addition to the typical reasons for rebooting the Monarch (fixing errors or other
issues), a reboot also saves the Monarch’s IP address and status to a connected
USB device (USB port 2) as a text file. This is a convenient way to find the
Monarch’s IP address.
Remarks
•
The Reset button is recessed in order to prevent unintended activation. Use a
straightened paper clip, or similar device, to press the Reset button. *** Note that
the RESET logo is the circular one with the arrow. The Reset pinhole is just
above it.
• A power cycle of the Monarch LCS also performs a simple reboot, not a reset
to factory defaults.
• When using the Reset button, any saved profiles for streaming and recording
are maintained, and all logged errors are cleared.
The device will be finished
rebooting when the flashing yellow
LED turns off.
• Holding the Reset button pressed for more than five seconds will reset the
device to factory defaults. A reset allows you to switch to a Static IP or load pre-
configured Monarch settings from a configuration file on a USB device connected
to USB port 2.
• For information on how to view and clear errors using the Command Center,
please refer to the operation manual accessible in the Support section of this