Lochinvar Power-fin 1002 User Manual

Other manuals for Power-fin 1002: Service Manual, Installation & Operation Manual

Summary of Power-fin 1002

  • Page 1

    User manual models: 502, 752, 1002, 1302, 1501, 1701, and 2001 up to 5:1 turndown if the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. This appliance must not be installed in any location where gasoline or...

  • Page 2

    User’s information manual 2 hazard definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 please read before proceeding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1. Maintenance schedule . . . . . . . . . . . ....

  • Page 3

    Please read before proceeding user’s information manual 3 notice this is a gas appliance and should be installed by a licensed electrician and/or certified gas supplier. Service must be performed by a qualified service installer, service agency or the gas supplier.  warning if the information in th...

  • Page 4

    User’s information manual 4 please read before proceeding  warning to minimize the possibility of serious personal injury, fire, or damage to your appliance, never violate the following safety rules: 1. Boilers and water heaters are heat producing appliances. To avoid damage or injury, do not store...

  • Page 5

    1 maintenance schedule user’s information manual 5  warning follow the maintenance procedures given throughout this manual. Failure to perform the service and maintenance or follow the directions in this manual could result in damage to the appliance or system, resulting in severe personal injury, ...

  • Page 6

    User’s information manual 6 1 maintenance schedule maintenance procedures appliance must be serviced and maintained  warning the appliance must be inspected and started annually at the beginning of the heating season by a qualified service technician. In addition, the maintenance and care of the po...

  • Page 7

    1 maintenance schedule (continued) user’s information manual 7 inspect condensate system 1. Inspect the condensate drain line, condensate pvc fittings, and condensate trap on an annual basis. Figure 1-1_condensate trap flush condensate trap with water 1. Remove the four (4) screws securing the top c...

  • Page 8

    User’s information manual 8 2 operating instructions.

  • Page 9

    User’s information manual 9 3 smart system control module access modes user the user can adjust the space heating target temperature and the tank target temperature (if a tank sensor is used) by using the up and down buttons (fig. 3-1) at any time during normal operation. By entering the user code (...

  • Page 10

    User’s information manual 10 parameter table menu sub item description see page user access installer access display modify display modify a 1 heater model 11 yes no yes no 2 user code 11 yes yes yes yes 3 date and time 11 yes yes yes yes 4 software version 11 yes no yes no 5 temperature units 11 ye...

  • Page 11

    User’s information manual 11 viewable and changeable control parameters a: general heater model the control will display “lochinvar” as the model number because the same control is used on several models. This will be displayed when parameter a1 has been accessed. This parameter is not changeable. U...

  • Page 12

    User’s information manual 12 3 smart system control module e: dhw settings dhw tank set point when a temperature sensor is installed in the dhw tank, the dhw tank set point sets the target temperature of the water in the tank. The user or installer can adjust this set point by accessing parameter e1...

  • Page 13

    User’s information manual 13 status display screens 3 smart system control module (continued) status display screens by using the previous/next ( , ) arrow keys on the smart system display panel, you can navigate through the nine (9) display screens. Each screen will contain two (2) viewable items. ...

  • Page 14

    User’s information manual 14 3 smart system control module status display screens (cont’d) by using the previous/next ( , ) arrow keys on the smart system display panel, you can navigate through the nine (9) display screens. Each screen will contain two (2) viewable items. The following is a descrip...

  • Page 15

    User’s information manual 15 3 smart system control module (continued) status display screens (cont’d) by using the previous/next ( , ) arrow keys on the smart system display panel, you can navigate through the nine (9) display screens. Each screen will contain two (2) viewable items. The following ...

  • Page 16

    Revision notes: revision b (pbx-pfx-user-rev b) reflects the addition of models 502 - 1302 to the manual revision c (eco c06058) reflects the removal of heat exchanger cleaning information in “maintenance and annual startup” section on page 5. Pbx-pfx-user-rev c cp-2m-7/10