Loctite 97006 Operation Manual

Manual is about: Digital Syringe Dispenser

Summary of 97006

  • Page 1

    R start cont bar psi 97006 equipment operation manual digital syringe dispenser part number 97006.

  • Page 2

    R start cont bar psi 97006 90–2 60 v ac/4 7–63 hz 2 am p in xs1 xs1: start loctite (ireland) ltd. Mad e in g erm any cat.N o.97 006 11 25 24 23 12 13 14 15 16 17 18 19 20 21 22 1 7 8 9 10 2 3 4 5 6 start cont bar psi.

  • Page 3: Contents

    3 1 please observe the following 1.1 emphasized sections 1.2 items supplied 1.3 for your safety 1.4 usage 2 description 2.1 displays, operating elements, and connections 2.2 theory of operation 2.3 functional sequence 2.3.1 time controlled mode 2.3.2 continuous mode 3 technical data 3.1 energy requi...

  • Page 4: Contents

    4 5 dispensing 5.1 filling the syringe 5.2 first operation 5.2.1 purging air from the syringe 5.2.2 adjusting the dispensed quantity 5.2.2.1 time controlled mode 5.2.2.2 continuous mode 5.3 changing the syringe 5.4 shutdown 5.5 returning to operation 6 care and maintenance 6.1 care 6.2 maintenance 7...

  • Page 5: Please Observe The Following

    5 please observe the following 1 1.1 emphasized sections warning! Refers to safety regulations and requires safety measures that protect the operator or other persons from injury or danger to life. Caution! Emphasizes what must be done or avoided so that the unit or other property is not damaged. No...

  • Page 6: Please Observe The Following

    6 1.3 for your safety for safe and successful operation of the unit, read these instructions completely. If the instructions are not observed, the manufacturer can assume no responsibility. Damage to the power cord or the housing can result in contact with voltage carrying parts that is dangerous to...

  • Page 7

    7 2.1 displays, operating elements, and connections ☞ ● fold out the illustration inside the front cover! 1 digital display display of the dispensing time[s] for a dispensing sequence. – during dispensing in time controlled mode, the dispensing time remaining is indicated. – during dispensing in con...

  • Page 8

    8 description - typical system set-up 2 5 button button for switching the measuring units for the dispensing pressure in the digital display. After each pressing of button , the indication of the selected dispensing pressure in the digital display changes to the other measuring unit [bar or psi] wit...

  • Page 9

    9 description - typical system set-up 2 11 hose clamp 12 syringe air line adapter assembly 13 end cap adapter 14 plug makes possible the clean emptying of the syringe 15 and prevents the permeating of the product with air as well as the product running back out of the syringe 15 into the control uni...

  • Page 10

    10 description - typical system set-up 2 2.2 theory of operation the loctite ® digital syringe dispenser (97006) is connected to an external pneumatic supply. The control unit of 97006 regulates the adjusted dispensing pressure and controls the dispensing during the selected dispensing time. Pressur...

  • Page 11: Technical Data

    11 3.1 energy requirements 3.1.1 electrics power supply 90 – 260 vac; 47 – 63 hz power consumption approx. 40 w power protection glass tube, fine wire fuse, 2 am internal control voltages 5 vdc; 12 vdc; 24 vdc 3.1.2 pneumatics pneumatic supply min. 2 bar (29 psi); max. 12 bar (174 psi) quality filte...

  • Page 12: Installation

    12 4.1 environmental conditions – no condensing humidity – no splashing water 4.2 space requirements 4.3 placement when the plug 14 is missing and the syringe 15 is handled in an improper manner, the product can enter and contaminate the control unit. ● place the control unit in a raised position! ●...

  • Page 13: Installation

    13 r start cont bar psi 97006 90–2 60 v ac/4 7–63 hz 2 am p in xs1 xs1: start loctite (ire land ) ltd . Mad e in g erm any cat.N o.97 006 p in installation 4 4.4 basic settings of the unit 4.5 connecting the unit ● use only the cable and hose sets supplied. R start cont bar psi 97006.

  • Page 14: Dispensing

    14 5.1 filling the syringe if loctite ® brand products are not properly handled, damage to health can result! ● observe general safety regulations for the handling of chemicals! ● observe manufacturer’s instructions! Request a safety data sheet for the product used! ● close the tip of the syringe 15...

  • Page 15: Dispensing

    15 5.2 first operation 5.2.1 purging air from the syringe ☞ to avoid air bubbles during dispensing, the tip of the syringe must be purged of air. ● hold the syringe 15 over a container since product will flow out! ● switch the power switch 10 to the position i (on). ● with the pressure regulator 9, ...

  • Page 16: Dispensing

    16 5.2.2 adjusting the dispensed quantity 5.2.2.1 time controlled mode this mode of operation is used for spot shaped wetting or drop dispensing. ● with buttons or , set the dispensing time to 0.50 s (factory setting). The indication of the dispensing time in the digital display begins blinking. ● w...

  • Page 17: Dispensing

    17 5.2.2.2 continuous mode this mode of operation is used for wettings of varying lengths or for the application of beads. ● with the pressure regulator 9, set the dispensing pressure to 0.50 bar (approx. 7 psi). An error message “ p pr re es ss s. . 0 0. .8 83 3 n no ok k ” with beeping is possible...

  • Page 18: Dispensing

    18 5.3 changing the syringe the unit need not be switched off to change the syringe. ● press the hose clamp 11 closed so that pressure cannot be applied to the syringe adapter 12 as a result of an unintentional start. ● replace the luer-lock tip cap 17 on the filled syringe 15 with a dispensing need...

  • Page 19: Dispensing

    19 5.4 shutdown ● switch the power switch 10 to the position o (off). Shutdown for longer periods of non-use for pauses in the work of longer than 14 days, place the system out of operation to prevent curing of the product. ● switch the power switch 10 to the position o (off). ● disconnect the pneum...

  • Page 20: Care and Maintenance

    20 6.1 care ● occasionally the o-ring at the syringe adaptor 12 should be lubricated with the enclosed silicone grease. This will prolong the life. ☞ clean hands after application of grease to assure surfaces to be bonded are clean. Otherwise a fusion might fail. ● clean adhesive residue from the pe...

  • Page 21: Troubleshooting

    21 type of malfunction possible causes correction troubleshooting 7 the digital display does not light. No change in the value on the digital display. No product, too little or too much product. The error message (with beeping) blinks in the digital display: p pr re es ss s. . = dispensing pressure....

  • Page 22: Troubleshooting

    22 troubleshooting 7 type of malfunction possible causes correction led in button or does not light. No start signal. No reaction from the buttons. Cont start – led is defective. – button is defective. – control unit is defective. – plug on the socket xs1: start 25 is loose. – foot switch 20 is defe...

  • Page 23: Documentation

    23 documentation 8 8.2 accessories and spare parts ☞ ● reference out the illustration inside the rear cover! Pos. No. Description loctite order no. 1 10 ml air line adapters (2 pcs/box) .............................................................97208 30 ml air line adapters (2 pcs/box) ..............

  • Page 24: Declarations of Conformity

    24 declarations of conformity 9 9.1 declarations of conformity.

  • Page 25: Declarations of Conformity

    25 declarations of conformity 9 9.3 service representative contact your local henkel representative. 9.2 warranty warranty henkel expressly warrants that all products referred to in this instruction manual for (97006 henkel digital syringe dispenser) (hereafter called "products") shall be free from ...

  • Page 26

    2 7 1 3 45 31,8 mm 30,0 mm 12,7 mm 56,1 mm 38,6 mm 6.

  • Page 27

    Loctite and chipbonder are registered trademarks of henkel corporation, u.S.A. © copyright 2004. Henkel corporation. All rights reserved. Data in this operation manual is subject to change without notice. Order code no. 8950106usa edition 01/2004 henkel corporation 1001 trout brook crossing rocky hi...