  • Page 1

    ™ ™ 600 control panel operation and troubleshooting 463-3000-07 initial - 24-jul-2007 1 canplus, cp600, canplus logo and lofa logo are trademarks of lofa industries, inc. Introduction the canplus™600 (cp600™) control panel is an economical platform to monitor and control electronically governed dies...

  • Page 2

    600 control panel operation and troubleshooting 2 463-3000-07 initial - 24-jul-2007 note most problems with electronically controlled engines can be pinpointed via ecu diagnostic messages. Use the display or ecu diagnostic tool to view fault codes. All engine state information and diagnostic codes d...

  • Page 3

    600 control panel operation and troubleshooting 463-3000-07 initial - 24-jul-2007 3 important safety information the warnings in this publication are not all inclusive. Lofa industries cannot anticipate every potential hazard. Appropriate safety rules and precautions should be followed with any tool...

  • Page 4

    600 control panel operation and troubleshooting 4 463-3000-07 initial - 24-jul-2007 operation turning the control system key to the run position energizes the ecu and displays a start-up screen while the display performs a self test. If the display beeps for longer than 1 second, it indicates a self...

  • Page 5

    600 control panel operation and troubleshooting 463-3000-07 initial - 24-jul-2007 5 analog gauge pages analog gauge pages provide four independent pages of analog gauges. To enable analog gauge pages, press any of the first 4 buttons to show the top level button bar and then press button 1 . Alterna...

  • Page 6

    600 control panel operation and troubleshooting 6 463-3000-07 initial - 24-jul-2007 digital gauge pages digital gauge pages display the same data as the analog gauge pages but in digital format. To enable digital gauge pages, press any of the first 4 buttons to show the top level button bar and then...

  • Page 7

    600 control panel operation and troubleshooting 463-3000-07 initial - 24-jul-2007 7 active alarms a flashing popup window is overlaid on the current screen when an active alarm is received. The popup includes a plain language description in addition to the standard spn-fmi pair defined by the sae j1...

  • Page 8

    600 control panel operation and troubleshooting 8 463-3000-07 initial - 24-jul-2007 configuration menu this configuration menu allows the user to set various operating parameters such as us or metric units, scale limits for tachometer and service timers. The configuration menu is entered by pressing...

  • Page 9

    600 control panel operation and troubleshooting 463-3000-07 initial - 24-jul-2007 9 display menu the display menu allows the user to configure items affecting how information is displayed. Units menu this menu allows the user to set the units used for speed, distance, pressure, volume and temperatur...

  • Page 10

    600 control panel operation and troubleshooting 10 463-3000-07 initial - 24-jul-2007 gauges menu this menu allows the user to configure aspects of the gauges displayed on the display. Button 3 selects the previous value while button 4 selects the next value of the highlighted item. Max rpm sets the ...

  • Page 11

    600 control panel operation and troubleshooting 463-3000-07 initial - 24-jul-2007 11 system menu the system menu allows the user to configure items affecting how the system functions. Demo the display supports several demo modes to operate with simulated data. Mode 1 simulates speed data and engine ...

  • Page 12

    600 control panel operation and troubleshooting 12 463-3000-07 initial - 24-jul-2007 com viewer displays last canbus messages received and engine configuration transmitted by the ecu. J1939 viewer this screen provides a hexadecimal dump of the last messages received on the canbus. This viewer displa...

  • Page 13

    600 control panel operation and troubleshooting 463-3000-07 initial - 24-jul-2007 13 display address as mentioned previously, every device has a unique address and the display is no different. In single engine setups the default display address is 40 (sae recommendation). Warning incorrectly configu...

  • Page 14

    600 control panel operation and troubleshooting 14 463-3000-07 initial - 24-jul-2007 pin change this allows changing the pin. The user is prompted for the current pin the user is prompted for the new pin. The new pin must be confirmed before the pin is changed. If the new pins match a confirmation s...

  • Page 15

    600 control panel operation and troubleshooting 463-3000-07 initial - 24-jul-2007 15 throttling menu the throttling menu allows the user to configure throttle control. Idle rpm selects the rpm the control system will request for idle speed. Idle can be set to compensate for parasitic loads such as h...

  • Page 16

    600 control panel operation and troubleshooting 16 463-3000-07 initial - 24-jul-2007 telemetry menu this menu allows configuring the optional telemetry system. Telem j1939 address defines address the telemetry module is using for canbus communications. Note the display will be unable to communicate ...

  • Page 17

    600 control panel operation and troubleshooting 463-3000-07 initial - 24-jul-2007 17 db viewer the database viewer displays and decodes all data monitored by the display. This diagnostic tool allows viewing data not normally displayed. The list can be scrolled using buttons 1 and 2 and closed by pre...

  • Page 18

    600 control panel operation and troubleshooting 18 463-3000-07 initial - 24-jul-2007 data communications failure the data communications failure popup icon flashes if the display does not detect data. The warning disappears and normal operation resumes once data is detected. Note incorrectly configu...

  • Page 19

    600 control panel operation and troubleshooting 463-3000-07 initial - 24-jul-2007 19 optional indicators power led (green) a solidly illuminated power led indicates the keyswitch is in the on position. Preheat led (amber) a solidly illuminated preheat led indicates the engine is preheating. When the...

  • Page 20

    600 control panel operation and troubleshooting 20 463-3000-07 initial - 24-jul-2007 typical j1939 wiring topology most electronically governed engine installations include a harness with built in j1939 backbone. Use twisted shielded pair with a drain wire for canbus wiring terminated with 120Ωresis...

  • Page 21

    600 control panel operation and troubleshooting 463-3000-07 initial - 24-jul-2007 21 harness sealed connectors the provided deutsch sealed weather-proof plug includes a locking ring device which must be turned counter clockwise to separate the connectors. To positively seat the connectors the lockin...

  • Page 22

    600 control panel operation and troubleshooting 22 463-3000-07 initial - 24-jul-2007 battery circuit requirements warning improper wiring can cause electrical noise, unreliable operation and may damage the control system or other components. All power connections must be free from foreign materials,...

  • Page 23

    600 control panel operation and troubleshooting 463-3000-07 initial - 24-jul-2007 23 suppression of voltage transients (spikes) warning the installation of voltage transient suppression at the transient source is required. Lofa follows sae recommended electrical environment practices. Inductive devi...

  • Page 24

    600 control panel operation and troubleshooting 24 463-3000-07 initial - 24-jul-2007 welding on equipment with electronic controls proper welding procedures are required to avoid damage to electronic controls, sensors and associated components. The component should be removed for welding if possible...

  • Page 25

    600 control panel operation and troubleshooting 463-3000-07 initial - 24-jul-2007 25 general troubleshooting for additional information, refer to engine manufacturer troubleshooting guide. No response from starter motor possible cause possible remedy no battery voltage to starter verify wiring and b...

  • Page 26

    600 control panel operation and troubleshooting 26 463-3000-07 initial - 24-jul-2007 engine troubleshooting note most problems with ecu controlled engines can be pinpointed via the ecu diagnostic messages. Use the display or ecu diagnostic tool to view fault codes. All engine state information and d...

  • Page 27

    600 control panel operation and troubleshooting 463-3000-07 initial - 24-jul-2007 27 control system troubleshooting control system does not perform self test possible cause possible remedy tripped overcurrent protection correct fault, replace or reset overcurrent protection faulty connection to batt...

  • Page 28

    600 control panel operation and troubleshooting 28 463-3000-07 initial - 24-jul-2007 testing a warning or shutdown shutdown simulation with ecu controlled engines requires using the ecu diagnostic tool. Refer to the diagnostic tool documentation to simulate a warning or shutdown. Testing canbus most...

  • Page 29

    600 control panel operation and troubleshooting 463-3000-07 initial - 24-jul-2007 29 diagnostic trouble codes (dtc) canbus diagnostic trouble codes are a pair of numbers; the suspect parameter number (spn) and failure mode identifier (fmi). The spn indicates the faulting subsystem and the fmi identi...

  • Page 30

    600 control panel operation and troubleshooting 30 463-3000-07 initial - 24-jul-2007 data parameters monitored this table lists the engine and transmission parameters that are monitored via the canbus. The parameters can be displayed by the user-configurable gauge pages or the single analog gauge. D...

  • Page 31

    600 control panel operation and troubleshooting 463-3000-07 initial - 24-jul-2007 31 icon parameter gauge pages single analog database fuel temperature intake manifold 1 temperature air inlet temperature exhaust gas temperature auxiliary temperature 1 engine ecu temperature exhaust gas port 1 temper...

  • Page 32

    600 control panel operation and troubleshooting 32 463-3000-07 initial - 24-jul-2007 glossary can controller area network (also referred to as canbus); serial communications protocol for electronic engines use dtc diagnostic trouble code; the combination of spn and fmi that identifies a specific err...

  • Page 33

    600 control panel operation and troubleshooting 463-3000-07 initial - 24-jul-2007 33 software revision history 1.30 initial release document revision information initial: 24-jul-2007..

  • Page 34

    600 control panel operation and troubleshooting 34 463-3000-07 revision - - 24-jul-2007 typical schematic the following page shows a typical schematic. Details vary from installation to installation. See the specific schematics for installation for details..

  • Page 35

    600 control panel operation and troubleshooting 463-3000-07 initial - 24-jul-2007 35 description rev date sheet part number of ©the information contained in this drawing is confidential and the sole property of lofa industries inc. Reproduction or dissemination in whole or in part in any form or med...

  • Page 36

    463-3000-07 initial - 24-jul-2007.