Logic CAM-200 Technical Manual - page 5
Logic IO ApS.
Ph: (+45) 7625 0210
Holmboes Allé 14
Fax: (+45) 7625 0211
8700 Horsens
Email: info@logicio.com
Denmark
www.logicio.com / www.rtcu.dk
CAM-200 – Technical Manual 1.00
Page 5 of 6
Installation
MX2i Pro/Pro+ and DX4 Pro Connection
The CAM-200 is connected to serial port 1 (service port) on the RTCU MX2/DX4. For this
purpose a 3 meter cable is delivered, which also allows placement of the CAM-120 away
from the RTCU X32 unit itself.
Power supply for the CAM-200 is controlled by the RTCU unit. This keeps the power
consumption kept at a minimum, only turned on when taking snapshots.
Lens adjustment
After the CAM-120 is placed correctly, the focus needs adjustment. This is done by
loosening the screw that locks the lens and turning the lens carefully left or right manually,
depending on the distance to the objective to focus on.
Figure 2: Lens adjustment
Screw