1 luna 1000 - 1300 rd gold gas instruction for installation and use passion for fire english 06-2012.
Instruction for installation and use - luna 1000-1300 rd gold - gas 2 v e r y i m p o r ta n t i n s ta l l at i o n i n s t r u c t i o n s f o r t h e m - d e s i g n g a s f i r e p l a c e s t h e s u p p l i e r ta k e s n o r e s p o n s b i l i t y f o r a n y p o s s i b l e d a m a g e , p ...
Instruction for installation and use - luna 1000-1300 rd gold - gas 3 summary 1. General remarks .............................................................. 5 2. Connection .......................................................................... 5 3. Installing the fireplace ......................
Instruction for installation and use - luna 1000-1300 rd gold - gas 4 open closing key if some dust or waste is seen on the window ( inside and outside ), clean this before the first use of the fireplace. Cleaning the win- dow is the only maintenance action that can be done by the consumer open and ...
Instruction for installation and use - luna 1000-1300 rd gold - gas 5 1. General remarks this is a moulding of the closed combustion system, designed for the atmosphere and comfort of your living-room. It constitutes an efficient source of heat and gives the impression of a real chim- ney fire. The ...
Instruction for installation and use - luna 1000-1300 rd gold - gas 6 3. Installing the fireplace after having checked the appliance, you ready to install your appliance. This is done as follows 3.1.1 positioning the fireplace place the fireplace on a stable surface using the adjustable feet. Adjust...
Instruction for installation and use - luna 1000-1300 rd gold - gas 7 4. Installing the chimney install the concentric flue duct as indicated by ontop - metaloterm. The only authorised pipes are ontop metaloterm™. Ontop-metaloterm tested our fireplace with their conduct and we only garantee a good w...
Instruction for installation and use - luna 1000-1300 rd gold - gas 8 pic. 1 roof exit ( c31 ) Ø 150/100 after elbow 90° Ø 200/130 appliance c (min) c (max) restriction 1000 rd 2 m 10m Ø 75 1300 rd 3 m 10m Ø 75 Ø 200 / 130 appliance c (min) c (max) restriction 1000 rd 2 m 10m Ø 75 1300 rd 2 m 10m Ø ...
Instruction for installation and use - luna 1000-1300 rd gold - gas 9 pic. 2 roof exit via existing chimney (c91) it is obligatory to use the sanitation set ussan with placing. Ø200(min) / Ø 130 appliance c (min) c (max) restriction hr+ (as from 2 m) 1000 rd 2 m 10m Ø 75 1300 rd 2 m 10m Ø 75 this us...
Instruction for installation and use - luna 1000-1300 rd gold - gas 10 pic. 3 wall exit (c 11 ) Ø 200 / 130 appliance a (min) b (min) b (max) restriction 1000 rd 1 m wall exit a Ø 75 1300 rd 1 m wall exit wall exit Ø 75 a = m in . 1 m b 2 5 5 elbow min. 90° 3° do not use a reduction 200/130 to 150/1...
Instruction for installation and use - luna 1000-1300 rd gold - gas 11 pic. 5 roof exit with 90° bends caution : if the vertical lenght is over 3 meter longer than the horizontal lenght, you will need to place a reduction ring of Ø 75. Appliance Ø 150/100 and Ø 200/130 1000 rd / 1300 rd for each 90°...
Instruction for installation and use - luna 1000-1300 rd gold - gas 12 see page 37,38 and 39 for further information about installation pic. 1 pic. 2 pic. 3 referential distances in regards to finishing the mantlepiece a very essential point when setting up the luna gold is that the distance has to ...
Instruction for installation and use - luna 1000-1300 rd gold - gas 13 the enclosure of the furnace must be provided with ventilation grills or openings allowing for the elimination of heat by convection. It is possible to have a convection kit fitted with the furnace. This system directs the heat i...
Instruction for installation and use - luna 1000-1300 rd gold - gas 14 design grid ( outlet ) with 2 connections outlet convection inlet convection outlet convection inlet grid convection air inlet grid convection air design grid ( outlet ) with 2 connections 2 dm² 4 dm² design grid ( outlet ) with ...
Instruction for installation and use - luna 1000-1300 rd gold - gas 15 you have to connect at least the two appertures situated at the top of the appliance following pic. 1 the stove may not be placed direct on the stove may not be placed direct on the floor, wthout the feets. This to allow natural ...
Instruction for installation and use - luna 1000-1300 rd gold - gas 16 7. Mounting a 3-sided frame please pay attention to leave approx 2 mm inbetween the frame and the finishing material ( heat = expansion) pic 1 3-sided frame 2,25cm 4 sided frame (lower piece) sideframe upper frame pic 3 pic 4 pic...
Instruction for installation and use - luna 1000-1300 rd gold - gas 17 put the big imitation coal pieces around the burner. Put the little imitation coal peices on the burner and here and there bet- ween the big coal pieces. 8. Putting in place the logs, diamond, sapphire and white stones • please c...
Instruction for installation and use - luna 1000-1300 rd gold - gas 18 1 2 3 4 5 6 7 8 9 5 6 7 8 9 1 2 4 3 luna 1000 rd gas.
Instruction for installation and use - luna 1000-1300 rd gold - gas 19 luna 1000 rd gas.
Instruction for installation and use - luna 1000-1300 rd gold - gas 20 1 2 3 4 5 6 7 8 9 5 6 7 9 1 2 4 3 8 10 11 12 10 11 12 luna 1300 rd gas.
Instruction for installation and use - luna 1000-1300 rd gold - gas 21 luna 1300 rd gas.
Instruction for installation and use - luna 1000-1300 rd gold - gas 22 9. First-time use the masonry and plaster surrounding a recently installed furnace hold a great deal of moi- sture, which must first evaporate before commissioning the appliance. If not, the plaster may crack or split. Ask your i...
Instruction for installation and use - luna 1000-1300 rd gold - gas 23 11. Startpilot the m-design gas appliance are provided with “constant startpilot”. After the first use or when the winterperiod is coming and you use the fireplace daily, you must let the startpilot switch on. Don’t switch it off...
Instruction for installation and use - luna 1000-1300 rd gold - gas 24 13. Specifica tion sheet type of gaz na tural gaz prop an / lpg categorie i 2h i 2l i 2e+ i 2e i 3+ i 3b/p categorie g25 g20 g31 g30 type /type c 11 , c 31 , c 91 c 11 , c 31 , c 91 c 11 , c 31 , c 91 c 11 , c 31 , c 91 inlet pre...
Instruction for installation and use - luna 1000-1300 rd gold - gas 25 type of gaz na tural gaz prop an / lpg categorie i 2h i 2l i 2e+ i 2e i 3+ i 3b/p categorie g25 g20 g31 g30 type /type c 11 , c 31 , c 91 c 11 , c 31 , c 91 c 11 , c 31 , c 91 c 11 , c 31 , c 91 inlet pressure (mbar ) 25 20 30 37...
Instruction for installation and use - luna 1000-1300 rd gold - gas 26 luna 1000 rd gold gas * * connection gas on the back side * *.
Instruction for installation and use - luna 1000-1300 rd gold - gas 27 luna 1300 rd gold gas * * connection gas on the left side *.
Instruction for installation and use - luna 1000-1300 rd gold - gas 28 14. Guarantee this page is your warranty card. The guarantee is only valid for faults caused by construction defects or defects in the parts used to build the furnace. M-design offers a 12 month guarantee on all electronic parts ...