M Design LUNA GOLD 800DC Installation Manual And User's Manual - page 9
INSRUCTION MANUAL AND USE LUNA GOLD 800DC - 900CL - 900CR
Tableau N°2 / HAUTEUR MINIMALE DE CONDUIT DE CHEMINEE EN CAS DE REDUCTION DE CELUI-CI.
Tabel N°2 / MINIMALE HOOGTE VAN HET ROOKKANAAL IN FUNCTIE VAN DE REDUCTIE ERVAN
ø
300
ø 250
ø 200
ø 180
Luna Gold 900CL/CR
-----
≥ 5m
> 7m
Luna Gold 800DC
-----
> 6m
2.10 FLUE
The construction of chimney must comply with strict conditions:
All the Luna stoves have a standard flue opening of 250 mm. in diameter. Certain chimney
configurations may require different standard diameters. In that case, look at table for the
height of the flue and the possibility of reducing the diameter with the help of a reduction piece.
Note : per 45° change of direction, one must keep to within 1m of this table.
• The flue must be thermally insulated.
The opening into the flue and its position are very important.
• One individual flue does not have more than two changes of direction.
The angle of the corner of these changes of direction may not be greater than 45 ° with the
perpendicular.
• The existing obstacles in the vicinity of the opening into the flue must be taken into account.
• Do not connect more than one stove to a chimney flue.
MINIMUM HEIGHT OF THE FLUE IN TERMS OF ITS REDUCTION.
9