  • Page 1

    Instructions for installation and use of zino 700,900,1100

  • Page 2

    Warning : the suplier takes no responsibility for any possible damage, poor working appliances and accident as a result of incorrect installation. 1.General ............................................................................ 3 1.1. Transport and installation ...................................

  • Page 3

    1 general 1.1 transport and installation • the zino is transported in a horizontal position. •for facilitate transport you can use a set of solid rubber straps/belts. Before the installation of zino it is necessary to check that the door mechanism functions properly and that the interior lining of t...

  • Page 4

    Caution: it is not necessary to overload the fireplace with wood. 1kg dried wood gives a 4kw power. Example: a fireplace with 80% return gives a power for about 3,2kw for 1kg dry wood. If you want a power about 6-7kw, it is just enough to put 2kg wood in the fireplace. This is like two normal pieces...

  • Page 5

    Warning! When connecting chimney from behind so you have to remove the cap on the chimney shell and the stopper ( see arrow pic.5 ) and then the stopper fitted to the top slot, which will remain free to disassembling the chimney. 2.3 safe distance fireplace stoves type „zino“ from flammable materi- ...

  • Page 6

    The combustion pipe might be of black respectively stainless steel pipes and elbows. The flue connection must be made by the shortest route to the flue by stn 73 4210. The combustion pipe should be implemented and consolidate in order it cannot be released accidentally or spontane- ously. All fluing...

  • Page 7

    3. Security conditions in operating the fireplace furnace type series “zino” should observe the following pre cautions: •the fireplace furnace type series “zino” must only be operated by an adult. •a minimum distance of 80cm clearance to each side and 30cm back of the appliance must be maintained to...

  • Page 8

    5. Maintenance the customer must regularly clean ashes from an ashtray on a grid /after two full-time heating/ and check whether there is excessive fouling the ash chamber/see ( pic.8 ) one to two times per heating season /by intensity of use and according to characteristics of the fuel/ need to che...

  • Page 9

    5.1 method of removal and installation of the deflector plates and pass the dismantling of the deflector plate 1: -lift plate up / approx 3cm / and remove the stainless steel beam to each slide and push to one side and a diagonal slide it out of the fireplace. -pull the plate to pull himself / appro...

  • Page 10

    6. Specifications identification of the type of fireplace furnace type „zino“is as follows: manufacturer: m-design benelux bvba type : „zino......................“, usable power range: 3-8kw standard: stn en 13240 „keep operating instructions” “the unit can be connected to a common chimney“ “use onl...

  • Page 11

    6.1 spare parts 11.

  • Page 12

    6.2 drawing 12.

  • Page 13

    7.Guarantee terms and items covered 7 years` guarantee on the general structure 2 years` guarantee on the parts, no guarantee on glass, seals and lining the combustion chamber (skamol plates) 8. Guarantee conditions the claim must be submitted to the warranty, otherwise the claim is recognized. 1. T...