M2 PZ-4 User Manual

Summary of PZ-4

  • Page 1

    Stereo microscope user manual this manual is written for stereomicroscope.To ensure the safety, obtain optimum performance and to familiarize yourself fully with the use of this microscope, it is recommended strongly that you study this manual thoroughly before using the microscope..

  • Page 2: Contents

    1 contents user notice .............................................................................. 2 1. Components ................................................................................ 4 2. Assembly ..................................................................................... 5...

  • Page 3: User Notice

    2 user notice 1. Safety precaution 1. Carefully open the box, avoid the accessories, like lens, dropping to ground and being damaged. 2. Check the input voltage, be sure the input voltage which signed on the microscope is consistent with the power supply voltage, or it will bring a serious damage to...

  • Page 4

    3 6. If the microscope is splashed by liquid during using, cut off the power at once, and wipe up the moisture. 7. Do not disassemble any parts of the microscope, which will affect the function or decline the performance of the microscope. 8. Place the instrument in a cool, dry position. When not us...

  • Page 5: 1. Components

    4 1. Components stereo microscope stereo microscope adjustable wf10×eyepieces focusing assembly binocular viewing head zoom body clamping knob objectives glass stage standard base brightness adjusting knob power cord main switch coarse focusing knob fine focusing knob.

  • Page 6: 2. Assembly

    5 2. Assembly 2.1 assembly diagram the diagram below shows how to assemble the various modules. The numbers indicate the order of assembly. ★when assembling the microscope, make sure that all parts are free of dust and dirt, and avoid scratching any parts or touching glass surfaces. Power cord micro...

  • Page 7: 2.2

    6 2.2 detailed assembly procedure 2.2.1 mounting binocular viewing head (fig.1 fig.2) 1. Rotate the objective① into the objective mount thread on the lower end of the zoom body. ② , as ③ in fig.2. 2. Aligning the positioning pin of the zoom body③ to the positioning groove on the binocular viewing he...

  • Page 8

    7 2.2.2 mounting binocular head (fig.3) loose the clamping bolt⑦ on the pillar⑥ and insert the binocular head and zoom body assembly⑧into the bracket of the pillar, then screw down the bolt⑦. 2.2.3 mounting eyepieces (fig.3 fig.4 fig.5) 1. Remove the eyepiece dust caps⑨ and gently insert two adjusta...

  • Page 9

    8 2.2.6 mounting aperture iris diaphragm attachment (fig.8 fig.9) ○aperture iris diaphragm attachment is optional. 1. Use the provided hexagonal driver to loose the clamping bolt and remove the binocular viewing head ①. 2. Mounting the aperture iris diaphragm attachment② to the top end of the zoom b...

  • Page 10

    9 3. Adjustment and operation 3.1 adjusting binocular viewing head 3.1.1adjusting interpupillary distance (fig.10) different users have different interpupillary distances. So when users change, do the interpupillary distance adjustment. While looking through the eyepieces, hold the left and right of...

  • Page 11: 3. 2 Focus Adjustment

    10 3. 2 focus adjustment 3.2.1 adjusting the rotation tension of the focus adjustment knob (fig.13 fig.14) for these microscopes ,the tension has been adjusted well before delivery. 1.rotate the focus adjustment knob① to move the slider② to a lower place for fear that the zoom body drops down sudden...

  • Page 12: 4.specification

    11 4.specification 5. Troubleshooting under certain conditions, performance of this unit may be adversely affected by factors other than defects. If a problem occurs, please review the following list and take remedial action as needed. If you cannot solve the problem after checking the entire list, ...

  • Page 13: 6. Outfit

    12 view dirt on eyepiece clean eyepiece 3 . the visibility of the image is poor. Dust on objective front lens. Clean lens surface 6. Specimen image blurs when zoom magnification is changed. Diopter ring is not correctly adjusted. Adjust it correctly. 7 not in complete focus on specimen. Focus specim...