MA Lighting 2-Port Node Manual Manual - page 19
Technical Service:
tech.support@malighting.com
; +49.5251.688865-30 Emergency Line: +49.5251.688865-99 2-Port Node Version 1.1
19
19
19
19
19
UPDATE
(do not use in live situation)
The 2-Port Node can only be updated from a grandMA console or using the onPC software. To do so, the 2-Port
Node must be present in the same network as the console (grandMA, grandMA light, grandMA ultralight, grandMA
Micro, Offline or onPC), i.e. the first 3 IP address groups must be identical. This very console must run the desired
software version (5.7 or higher).
If the cell „version“ has a red background, the 2-Port Node runs a software version different from that of the console
or onPC. In this case, you have to adapt the software versions as follows:
On the console or in onPC, open the TOOLS / MA NETWORK CONFIGURATIONS / 2-PORT menu
If the 2-Port Node does not appear in the overview (other network number), press the SHOW ALL button. This
will bring up all 2-Port Nodes.
Press the UPDATE ALL NODES button
After an automatic reboot of the 2-Port Node, the cell „version“ must have a grey background.
NOTE: if the warning "waiting for update" appears in the display, the version update is unimplemented .
Repeat the update procedure (see above).
NOTE:
Make sure not to implement components into the network which would slow down the transmission
rate to 10Mbit.
On consoles with serial numbers higher than those given below, using 2-Port Nodes in a network will not present
any problems, as they already have a 100Mbit network controller and 256MB memory installed:
- grandMA
SN 490 and higher
- grandMA Light
SN 317 and higher
- grandMA UltraLight
SN 232 and higher
- grandMA Replay Unit
SN 38 and higher
Consoles with lower serial numbers must be upgraded to 256MB RAM and receive a 100Mbit network controller