Temperature
The maximum set temperature is 104°F
(40°C) and the minimum set temperature is 80°F
(27°C). The current water temperature or, if the pump
has not been running, two dashes, will show on the
display. If dashes are displayed, you must first start
the pump by pressing the JETS 1 pad. Wait until the
water temperature is displayed (approximately 2
minutes).
The set temperature of your spa may easily be
increased or decreased at any time using the WARM
or COOL pads. When either of these pads is touched,
the set temperature will be displayed in the LCD
window. Each successive touch will change the set
temperature 1°F in the chosen direction. After 3
seconds the LCD will automatically display the water
temperature or dash lines.
If the spa is set in Standard mode or in a
filtration cycle, adjusting the set temperature may
result in activating the heater. When the heater is
operating, the heat icon will be displayed in the LCD.
Note: 240-Volt spas that are wired with the 30 Amp
option will not heat when Pump 1 is on in high speed,
or when Pump 2 is in operation.
JETS 1
Touch
the
JETS 1 pad to activate the primary
filtration pump. The sequence of the jet action is:
1 touch = Low jets
2 touches = High jets
3 touches = Off
JETS 2
Touch
the
JETS 2 pad to activate the therapy
pump. The sequence of jet action is:
1 touch = Low jets
2 touches = High jets
3 touches = Off
The low speed operation of Pump 1 is timed to
automatically turn off after two hours of operation.
The high speed operation of Pump 1, and the low and
high speed operation of Pump 2, is timed to
automatically turn off after 15 minutes of operation.
Note: Pump 1 will automatically operate in low speed
whenever the spa calls for a filtration cycle or heat.
When this automatic activation occurs, the low speed
of Pump 1 cannot be turned off; however, all other
control functions can be activated.
Temperature Lock
Once you have set the desired water
temperature, you may lock-in the new setting to
prevent unauthorized temperature adjustments to your
spa. To lock the set temperature:
Touch WARM or COOL, then touch TIME, JETS 1,
and WARM within 3 seconds. The “TL” indicator
will light when the set temperature is locked.
Temperature
Unlock
To unlock the temperature, touch either WARM or
COOL, then touch TIME, JETS 1, and COOL
within 3 seconds. The “TL” indicator light will go out
when the set temperature lock is cleared.
Panel Lock
To help prevent unauthorized use of your spa, the
control system has a unique panel locking system.
To lock the panel, touch TIME, JETS 1, then
WARM within 3 seconds. When locked, the “PL”
indicator light will be on. Except for the time button,
everything will be frozen.
When the control panel lock is
engaged, all automatic spa functions will operate
normally but cannot be altered.
Panel Unlock
To unlock the panel, touch the TIME, JETS 1, and
COOL within 3 seconds. The “PL” indicator light will
go out when the panel lock is cleared.
Light
Touch the LIGHT pad to turn the digital lighting
system on and off. The light will automatically turn
off after 60 minutes of operation.