Mace MVC-PTZ-23X Product Manual

Manual is about: Indoor/Outdoor 23× PTZ Speed Dome Camera

Summary of MVC-PTZ-23X

  • Page 1

    Product manual 5101 nw 21st ave, suite 210 • fort lauderdale, fl 33309 www.Mace.Com • (877) 585-6223 mvc-ptz-23x indoor/outdoor 23× ptz speed dome camera.

  • Page 2

    2 table of contents 1 features and functions .................................................................................... 8 1.1 general introduction ...........................................................................................................................................8 1....

  • Page 3

    3 3 cable connection ............................................................................................... 15 3.1 multiple-function composite cable ................................................................................................................15 3.2 alarm cable connection ...

  • Page 4

    4 7.2 rs485 bus transmission distance ................................................................................................................37 7.3 connection methods and terminal resistance ...........................................................................................37 7.4 th...

  • Page 5: Welcome

    5 welcome thank you for purchasing our product! This user’s manual is designed to be a reference tool for the operation of your system. Here you can find information about this speed dome features and functions, as well as a detailed menu tree. Please keep it well for future reference! Before instal...

  • Page 6

    6 important safeguards and warnings 1 . electrical safety z all installation and operation here should conform to your local electrical safety codes. Z the power shall conform to the requirement in the selv (safety extra low voltage) and the limited power source is rated 24v ac in the iec60950-1. Z ...

  • Page 7

    6. About accessories always use all the accessories recommended by manufacturer. Before installation, please open the package and check that all the components are included in the package: contact you local retailer asap if something is missing in your package..

  • Page 8

    8 1 features and functions 1.1 general introduction this series quick installation speed dome product is an integrated high intelligent speed dome. It adopts water drop configuration design and has small and delicate shape. This is a digital and intelligent product of vivid video. The installation i...

  • Page 9

    9 1.2.6 auto scan camera scans back and forth regularly in a horizontal field. Here you need to set left and right limit and scan speed. You can set 5 scanning paths. 1.2.7 auto pattern memorize dome operation such as pan, tilt, and zoom to repeat. Focus and iris are in auto mode during auto pattern...

  • Page 10

    10 1.2.14 auto focus auto focus allows the lens to remain in focus during zoom-in, zoom-out and motion functions to get vivid image. You can use far or near button to adjust focus manually. 1.2.15 backlight compensation balance the brightest and darkest sections of a scene to produce a more vivid pi...

  • Page 11

    11 1.3.2 performance specifications power ac 24v/3a ( ±20% ) (includes temperature control circuit) camera driver consumption 11w decoder built-in engine stepper motor preset 255( in pelco protocol) auto tour 8 auto pattern 5 auto scan 5 privacy mask maximum 8 zones alarm input/output 7/2 informatio...

  • Page 12

    12 built-in decode all digital design. All data are in the connection board. No data loss when power off occurs. Z integrated design, high stability. Z quick installation speed dome max support 255 presets. Support 8 auto touring. Each touring max has 32 presets. Z 5 auto scan. Z 5 auto pattern. Eac...

  • Page 13

    13 2 protocol, baud rate, address setup before you operate, you need to set protocol, baud rate and address. Otherwise you can not control the product! 2.1 protocol and baud rate setup please configure the following settings before begin controlling dome: z protocol z baud rate z address note: pleas...

  • Page 14

    14 5 6 baud rate off off 9600bps on off 4800bps off on 2400bps on on 1200bps please refer to the parity setup sheet for detailed information. 7 8 parity off off none on off even off on odd on on none 2.2 set address dial switch sw2 is to set the address. See figure 2-2. Figure 2-2 the encode mode ad...

  • Page 15

    15 3 cable connection 3.1 multiple-function composite cable the multiple-function composite cable includes the audio/video connection port, rs485 connection port, and alarm input/output port. Please refer to the indication label on the multiple- function composite cable for detailed connection infor...

  • Page 16

    16 z when the activation mode is nc (normal close), dome alarms when there is high voltage. Low voltage will not activate the alarm. Note: z dome alarm input message is ground mode. Z dome alarm input signal are two modes: normal open and normal close. 3.2.1 system layout the system installation lay...

  • Page 17

    17 figure 3-3 note: please use shielded twisted pair. The shielded layer shall connect to gnd firmly; otherwise it may affect communication or video work. 3.2.1.2 star connection please refer to figure 3-4 for start connection information. Figure 3-4 3.2.2 alarm connection please refer to figure 3-5...

  • Page 18

    18 3.2.3 keyboard connection this series dome supports keyboard operation. You can use keyboard to control the dome and ptz. The display and control can work simultaneously. One keyboard can control maximum 255 speed domes. Please refer to figure 3-6. Figure 3-6 speed dome protocol is open and suppo...

  • Page 19

    19 4 menu 4.1 screen menu index note: err means current setup is invalid. … means there is submenu. The above diagram illustrates the overall structure of the speed dome setup menu. Note: z err means current setup is invalid. Display setting system information camera setting function setting alarm s...

  • Page 20

    20 addr : 001-h baud rate : 9600 parity : none protocol : pelco-p model : sd66xx temp : 032 ℃ software : v1.00 back exit system information display setting camera setting function setting alarm setting exit z please make sure all the cable connections are right. 4.2 self-diagnosis system information...

  • Page 21

    21 initial information addr information system time setting set north language : english ptz auto stop factory default restart back exit z exit : log out the system menu. 4.4 menu operation in the speed dome main menu, you can use the left/right button on the keyboard or in the speed dome terminal m...

  • Page 22

    22 addr : 001-h baud rate : 9600 parity : none protocol : pelco-d model : sd6663-hn temp : 032 ℃ software : v1.04.3 back exit move the cursor to initial information and then click confirm button, you can see the above interface. Here you can view dome basic information. 4.4.1.2 address information m...

  • Page 23

    23 move the cursor to display setup and then click confirm button, you can go to the third submenu. Please use the left/right button on the keyboard or in the speed dome terminal menu to set. After completed setup, please click save button to save current setup. Z preset title: display dome preset t...

  • Page 24

    24 z focus mode: there are two modes: manual/auto. Please use the left/right button on the keyboard or in the speed dome terminal menu to set. Z zoom speed; the zoom speed value ranges from 1 to 8. The bigger the value, the faster the speed. Please use the left/right button on the keyboard or in the...

  • Page 25

    25 day/night : auto day time : 07h 00m night time : 19h 00m save back exit o auto: it becomes valid after you set the exposure compensation, backlight compensation (blc), slow shutter, wide dynamic region (wdr). O manual: it becomes valid after you set the gain setting, shutter, iris setting, wide d...

  • Page 26

    26 preset pan scan auto cruise pattern idle motion time task privacy masking back exit picture flip : off freeze function : off camera factory default camera restatrt back exit z day time: current setup becomes valid when day/night mode is time. Move the cursor to day time item and then click confir...

  • Page 27

    27 preset no : 001 title : preset001 setting call back exit z preset: move the cursor to preset and then click confirm button to go to the third submenu. Z pan: move the cursor to pan and then click confirm button to go to the third submenu. Z scan: move the cursor to scan and then click confirm but...

  • Page 28

    28 scan no : 001 set left limit set right limit scan speed : 160 run stop back exit to begin rotation. Call preset 33 to enable ptz 180 degrees rotation. Call preset 34 to set dome position as 0. Z set preset: set preset 26 or 92 to set scan left limit. Set preset 27 or 93 to set scan right limit. S...

  • Page 29

    29 move the cursor to highlight cruise item and then click confirm button to go to set interface. Z cruise no : here is to ser tour number. The value ranges from 1 to 8. Please use the left/right button on the keyboard or in the speed dome terminal menu to set. Z cruise setting: move the cursor to c...

  • Page 30

    30 pattern function can memory ptz operation and camera focus zoom in and zoom out. From the start position, dome begins auto movement repeatedly. This series ip dome supports maximum 5 patterns and one pattern can max support 400 commands. Move the cursor to pattern and click confirm button. Z patt...

  • Page 31

    31 idle func : off idle time : 010min idle action : preset preset no : 001 auto scan no : 001 cruise no : 001 pattern no : 001 save back exit there are maximum 8 privacy mask zones in 360 degrees. System supports two privacy zones in one screen (tilt angle ranges from 0 to 45 degrees.) note: z for s...

  • Page 32

    32 time task : off start time : 06h 00m end time : 10h 00m task action : scan preset : 001 scan : 001 tour : 001 pattern : 001 save back exit • idle time: system idle period. The value ranges from 1 to 720 minutes. Please use the left/right button on the keyboard or in the speed dome terminal menu t...

  • Page 33

    33 alarm no : 01 action : none contact : n/o preset : 001 auto scan : 001 cruise : 001 relay out : offs reset delay : 3s save back exit • preset: the speed dome will go to the selected preset at the specified time if you select the time task as preset. The value ranges from 1 to 80. • scan: the spee...

  • Page 34

    34 1 → 5s : 1 means the first relay output.5s means the relay will reset automatically in five seconds after alarm occurs. 1&2 → 5s : 1&2 means the first relay and the second relay work at the same time. Z reset delay: here is for you to set alarm reset time. Please use the left/right button on the ...

  • Page 35

    35 5 faq 5.1 daily maintenance please clean dome cover regularly to get vivid image. Handle the cover with care. Use water to wash. Don’t use cloth to clean. Use mild detergent to clean if there is too much dust. Note: the sweat from your hand may erode plating surface, your nail may scrape dome cov...

  • Page 36

    36 6 appendix Ⅰ thunder proof and surge protection this series speed dome adopts tvs lighting protection technology. It can effectively prevent damages from various pulse signals below 1500w, such as sudden lighting and surge. While maintaining your local electrical safety code, you still need to ta...

  • Page 37

    37 7 appendix Ⅱ about rs485 bus 7.1 rs485 bus main feature rs485 is semi duplex communication cable of impedance 120 Ω . Its max load amount is 32 effective loads (including main control device and devices to be charged). 7.2 rs485 bus transmission distance when we take 0.56mm (24awg) twisted-pair a...

  • Page 38

    38 7.4 the problem in practical use there are 120 Ω device terminal resistance in power socket. There are two connection ways. The first one is shown as in figure 7-3. It is the factory default connection method. Now the jumper caps (connection board) are connected to the second and third socket, th...

  • Page 39

    39 in this situation, we recommend rs485 distributor. This device can turn star type connection into the connection that conforms to rs485 bus industry standard, which can avoid the above mentioned problems and enhance communication reliability. See figure 7-6. Figure 7-6 7.6 rs485 bus faq phenomeno...

  • Page 40

    40 8 appendix toxic or hazardous materials or elements toxic or hazardous materials or elements component name pb hg cd cr vi pbb pbde sheet metal ○ ○ ○ ○ ○ ○ plastic parts pcb housing ○ ○ ○ ○ ○ ○ camera driver ○ ○ ○ ○ ○ ○ bearing ○ ○ ○ ○ ○ ○ connection cable motor (if possible) power (if possible) ...

  • Page 41

    41 • if there is any uncertainty or controversy, please refer to the final explanation of us. • please visit our website or contact your local service engineer for more information..