Mackie Sound Palette SP1200 Instruction Manual - Introduction

Other manuals for Sound Palette SP1200: Specifications, Brochure
Manual is about: Mackie Instruction Manual Single-Channel Program Controller/Amplifier SP1200

Summary of Sound Palette SP1200

  • Page 1

    Sp1200 music controller inputs off 3 0 3 6 9 15 30 55 1 2 3 4 on ol status power comm port zone a master volume phantom paging gain +40db mic/line input a caution: to reduce the risk of fire replace with same type fuse and rating 115v 60hz fuse 115/ t4a 120 watts 230v 50hz fuse 230/ t2a 120 watts 1 ...

  • Page 2: 1. Safety Instructions

    Sp1200 – 2 caution avis risk of electric shock do not open risque de choc electrique ne pas ouvrir caution: to reduce the risk of electric shock do not remove cover (or back) no user-serviceable parts inside refer servicing to qualified personnel attention: pour eviter les risques de choc electrique...

  • Page 3: Introduction

    Sp1200 – 3 audio expansion connectors are provided on the rear panel for connecting multiple sp1200s, with shared audio via balanced busing. Each of the four program input signals are internally balanced and can be independently assigned to the balanced bus with internal assignment switches. The loc...

  • Page 4

    Sp1200 – 4 front panel features inputs select buttons are used to choose the program source for the zone. Only one source may be selected at a time. These are non-priority inputs. However, input 4 can become a program priority input by setting the amp address switch #7 up. In this mode, when a signa...

  • Page 5

    Sp1200 – 5 the paging mic vox variable control adjusts the ducking threshold for the paging mic. Rotate the control clockwise to reduce the threshold. Rotate the control counterclockwise to increase the threshold. Mic/line input is provided to connect a local microphone. This is a 3-pin phoenix-type...

  • Page 6: Installation

    Sp1200 – 6 3. Installation application diagrams phantom paging gain +40db mic/line input a caution: to reduce the risk of fire replace with same type fuse and rating 115v 60hz fuse 115/ t4a 120 watts 230v 50hz fuse 230/ t2a 120 watts 1 2 3 4 1 2 3 4 5 6 7 8 0 i program eq 1 2 3 4 zone a gain +40db p...

  • Page 7

    Sp1200 – 7 phantom paging gain +40db mic/line input a caution: to reduce the risk of fire replace with same type fuse and rating 115v 60hz fuse 115/ t4a 120 watts 230v 50hz fuse 230/ t2a 120 watts 1 2 3 4 1 2 3 4 5 6 7 8 0 i program eq 1 2 3 4 zone a gain +40db phantom on the following are trademark...

  • Page 8

    Sp1200 – 8 internal bus assign switches s1 s5 12345678 on 12345678 on internal bus assign switches sp1200 switch settings 1 2 3 4 5 6 7 8 0 i zone a ambient mic off/on off on down up amp address input 4 priority off/on master/slave 1 2 3 4 5 6 7 8 local 1 2 3 4 remote 1 2 3 4 1 2 3 4 sp1200 switch s...

  • Page 9

    Sp1200 – 9 d: room combining—zones note: this application provides independent source selection for each zone, or common input source selection for both zones (room combining). Both dx8 selection remote controls are used to select presets 1 and 2. For example, preset 1 might route the cd player and ...

  • Page 10

    Sp1200 – 10 applications a: typical mono application this diagram depicts a typical setup, using the sp1200 in a mono application. A digital satellite service (dss) is connected to input 1, which also serves as the music-on-hold for the telephone system. A cd player and cassette deck are con- nected...

  • Page 11

    Sp1200 – 11 caution: when using multiple sp1200s that use the expansion bus, these switch settings must be unique to each unit or you can damage your sp1200(s). Never assign more than one program source to the same channel on the expansion bus. If there is a requirement for music-on-hold, use input ...

  • Page 12

    Sp1200 – 12 signal pin no. Input 1 left (+) pin 1 input 1 left (–) pin 14 input 1 right (+) pin 2 input 1 right (–) pin 15 ground pin 3 input 2 left (+) pin 16 input 2 left (–) pin 4 input 2 right (+) pin 17 input 2 right (–) pin 5 ground pin 18 input 3 left (+) pin 6 input 3 left (–) pin 19 input 3...

  • Page 13

    Sp1200 – 13 connecting the rs485 serial port this is a 3-pin phoenix-type connector that follows standard rs485 protocol. Select either a data-grade shielded twisted pair cable or a standard 3-conductor microphone cable for this connection. The rs485 port is wired as follows: pin 1 = a (non-invertin...

  • Page 14

    Sp1200 – 14 eq bypass jumper j6, located on each filter board, allows you to bypass the 3-band eq for the four program inputs. Jumper pins 1 and 2 to bypass the eq. Jumper pins 2 and 3 to engage the eq (default). Note: the top input board must be removed in order to access jumper j6 on the filter bo...

  • Page 15

    Sp1200 – 15 ac power considerations each sp1200 draws an average of 3 amps of ac line current (@ 120vac) when fully loaded and playing music with a relatively high crest factor. Voltage conversion the sp1200 can be configured to operate at 115v ac or 230v ac. See appendix c for instructions on how t...

  • Page 16: Operation

    Sp1200 – 16 4. Operation • bus assign switches are used to assign a program input source to the balanced expansion bus. There are four switches for each program input source: left (+), left (–), right (+), and right (–). Caution: when using multiple sp1200s that use the expansion bus, these switch s...

  • Page 17

    Sp1200 – 17 paging mic control the paging mic control connector is provided to connect a manual paging switch. Connect a normally-open switch between gnd and zone a (to page in zone a only), or gnd and all call (to page over the entire system--if using multiple units). The voice-activated (vox) cont...

  • Page 18

    Sp1200 – 18 using inputs 1-4 connect the program sources to inputs 1-4. These could include a cd player, tape deck, tuner, satellite feed, tv audio, jukebox, or an audio feed from a live band. All four program inputs use unbalanced rca connectors and accept stereo line- level signals. Note: the inpu...

  • Page 19

    Sp1200 – 19 using the paging mic the paging mic is used to make announcements over the system. If the paging mic is a condenser mic or other type of mic that requires phantom power, move the phantom switches to the down position. Otherwise, leave them switched up. The paging mic can be voice-activat...

  • Page 20

    Sp1200 – 20 ambient mic calibration and placement 1. Connect the mt-3100 (or other microphone) to the ambient mic connector on the rear panel. Make sure the ambient mic switch is on (amp address switch #8 up). Locate the ambient mic in an appropriate position to pick up the ambient noise in the room...

  • Page 21

    Sp1200 – 21 using the eq each local mic/line input has a 2-band equalizer for adjusting the lows or highs on the microphone signal. When the controls are set to “u” (unity), the eq has no effect on the signal. Using the pre out/amp in connections the pre out and amp in connectors are provided to giv...

  • Page 22

    Sp1200 – 22 address switch #6 in the master position (up), and the other unit in the slave position (down). In this way, you can have one remote control operate both amplifiers that are assigned to the same zone. Note: the microprocessor polls the amp address switch when it initializes at power-up. ...

  • Page 23: Specifications

    Sp1200 – 23 3 0 3 6 9 15 30 55 direct output l r input 1 digitally controlled attenuators digitally controlled attenuator l + — r mackie industrial sp1200 block diagram (#01.02.01.Df) mackie industrial woodinville redmond bus assign + — +24vdc phantom paging mic gain +40db gain gain +40db 1 1 2 3 3 ...

  • Page 24

    Sp1200 – 24 sp1200 music controller sp1200 specifications power amplifier section continuous sine wave average output power, single channel driven: 200 watts into 8 ohms from 20hz to 20khz, with no more than 0.01% thd 100v rms into 50 ohms from 20hz to 20khz, with no more than 0.1% thd (j2/j3 in 100...

  • Page 25: Service Information

    Sp1200 – 25 disclaimer mackie industrial continually engages in research related to product improvement, new materials, and production methods. Design refinements are introduced into existing products without notice as a routine expression of that philosophy. For this reason, any current mackie indu...

  • Page 26: Appendix B: Button Modes

    Sp1200 – 26 appendix b: button modes press 1 on power up: agc reset • press and hold the input 1 button while powering up the sp1200. • release the input 1 button and the input 1 led blinks. This resets the agc for all four inputs to the default setting (–5 dbu). • press the input 1 button again and...

  • Page 27

    Sp1200 – 27 mackie designs. ™ risk of fire! Replace with fuse as marked © 2000 ® 055-286-00 rev:__ sp2400:soft start r1 c1 c3 r4 r3 r6 d1 f1 j3 j1 j4 j2 j8 j5 j11 j14 j9 j6 j10 j7 j13 j12 d2 jp1 r5 k1 r2 c2 4a sb 250v + brown blue yellow yellow/red black black/red yellow yellow/red black black/red j...

  • Page 28: Sp1200 Music Controller

    Sp1200 music controller mackie industrial 16220 wood-red rd. Ne • woodinville, wa 98072 • usa 888/337-7404 • outside the u.S.: 425/487-4333 fax: 425/487-4337 • www.Mackieindustrial.Com.