    Rev. Date 111714 © 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com 1.

  • Page 2

    2 © 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com rev. Date 111714.

  • Page 3

    Rev. Date 111714 © 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com 3 table of contents caution & safety .............................................................................................................................................................

  • Page 4

    4 © 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com rev. Date 111714 caution & safety read the entire manual before operating the fan. Ensure that all safety practices and instructions are followed during the installation, operation and servicing of the fan....

  • Page 5

    Rev. Date 111714 © 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com 5 caution & safety key safety system components macroair fans are engineered with key safety features to prevent pieces of the fan from falling in the unlikely event of a catastrophic failure...

  • Page 6

    6 © 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com rev. Date 111714 fan components motor mount assembly: • motor/gearbox, hybrid hub, and keyless bushing adapter attached to motor mount. • if ordered without safety screens, the hybrid hub cover, hub safety ...

  • Page 7

    Rev. Date 111714 © 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com 7 fan placement - general information sprinkler systems and fan placement in any installation where fire sprinklers are in place, do not interfere with their correct operation. Fans should be...

  • Page 8

    8 © 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com rev. Date 111714 fan placement - umh aireco dimensions warning: fans are not meant to be operated in windy conditions. The goal of this diagram is to determine the proper extension length to maintain a mini...

  • Page 9

    Rev. Date 111714 © 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com 9 universal mount universal mount extension guy wire kit umh components (ceiling mounting).

  • Page 10

    10 © 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com rev. Date 111714 fan mounting.

  • Page 11

    Rev. Date 111714 © 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com 11 mounting assembly - wall • mark a level line on the wall at the desired mounting height to locate the top edge of the upper mount plate. • use the mount as a template to carefully mark the...

  • Page 12

    12 © 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com rev. Date 111714 mounting assembly - pole • cut and mount bracketing: cut and assemble unistrut or equivalent bracketing (not included). Use the mount assembly as a template for length and hole spacing. Se...

  • Page 13

    Rev. Date 111714 © 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com 13 ceiling installation - i-beam control panel fan unit guy wire cable safety cable i-beam clamps motor cable (25 feet provided) aireco not pictured. Installation methods are the same..

  • Page 14

    14 © 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com rev. Date 111714 i-beam mounting assembly - ceiling • attach the i-beam clamps to the top of the universal mount with the provided hardware pack. • clamp the universal mount to the i-beam. • attach the ext...

  • Page 15

    Rev. Date 111714 © 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com 15 i-beam mounting assembly - ceiling mounting clamps guy wire with turnbuckle guy wire attachment points i-beam safety cable aireco not pictured. Installation methods are the same..

  • Page 16

    16 © 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com rev. Date 111714 ceiling installation - glulam control panel fan unit motor cable (25 feet provided) guy wire cable safety cable • the safety cable needs to be fed through a hole in the glulam, preferably ...

  • Page 17

    Rev. Date 111714 © 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com 17 glulam mounting assembly - ceiling • attach the glulam brackets to the top of the universal mount at a width that is wide enough to accomodate the glulam (the glulam brackets are adjustabl...

  • Page 18

    18 © 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com rev. Date 111714 glulam mounting assembly - ceiling mounting brackets guy wire with turnbuckle guy wire attachment points • attach the glulam brackets to the glulam and attach the top of the fan frame to t...

  • Page 19

    Rev. Date 111714 © 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com 19 glulam mounting assembly - ceiling mounting brackets guy wire with turnbuckle guy wire attachment points safety cable glulam aireco not pictured. Installation methods are the same..

  • Page 20

    20 © 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com rev. Date 111714 motor assembly & connections motor assembly • place the motor assembly on the mounting assembly, making sure the mount assembly pivot section is flat. • rotate the motor assembly to approx...

  • Page 21

    Rev. Date 111714 © 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com 21 rear safety screen • note: if ordered, safety screens must be installed to prevent injury because safety retainer links are not provided with units ordered with guards. • from the front of...

  • Page 22

    22 © 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com rev. Date 111714 blade strut attachment • slide one blade strut into any notch in the hub, chamfered (beveled edge) side facing you, radiused end towards the center of the hub. • insert two gold-colored 3/...

  • Page 23

    Rev. Date 111714 © 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com 23 blade & safety link assembly safety retainer link • note: safety retainer links are required to be installed on fans without guards. • slide the blades onto the blade struts and align the ...

  • Page 24

    24 © 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com rev. Date 111714 blade & safety link assembly the image above represents the correct installation of the blade and safety retainer links. Aireco not pictured. Installation methods are the same..

  • Page 25

    Rev. Date 111714 © 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com 25 front safety screen & safety cable front safety screen • line up the struts of the front screen with the struts of the rear screen. • attach the screens together by inserting the included ...

  • Page 26

    26 © 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com rev. Date 111714 electrical & safety cable installation warning! Motor cables and incoming power must never be run in the same conduit. Failure to install per macroair instructions, including wiring, may b...

  • Page 27

    Rev. Date 111714 © 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com 27 control panel overview terminate incoming power here motor cable gland (to be installed by customer) • control panels come pre-wired, as illustrated above. • a schematic is provided on the...

  • Page 28

    28 © 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com rev. Date 111714 control panel schematics.

  • Page 29

    Rev. Date 111714 © 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com 29 touchpad remote user interface forward reverse increase speed decrease speed speed % power button hidden button for dirve status / fault reset screen the touchpad remote will automatically...

  • Page 30

    30 © 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com rev. Date 111714 touchpad remote installation bezel touch screen wall mount enclosure wall mount screws (4 provided) flush mount screws (2 provided) single gang electrical box flush mounting (not provided)...

  • Page 31

    Rev. Date 111714 © 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com 31 touchpad remote lcd display front view rear view top view right view bottom view left view.

  • Page 32

    32 © 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com rev. Date 111714 touchpad remote enclosure front view rear view top view right view bottom view left view.

  • Page 33

    Rev. Date 111714 © 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com 33 guy wire installation (ceiling mount).

  • Page 34

    34 © 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com rev. Date 111714 guy wire installation (ceiling mount) • attach the turnbuckle end of the guy wires to the guy wire loops located on the fan frame with the provided quick links. • when laying out the locat...

  • Page 35

    Rev. Date 111714 © 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com 35 cable clamps guy wire tightening (ceiling mount) • with the aid of a level placed against the fan unit, tighten the turnbuckles by hand in a criss-cross pattern while periodically checking...

  • Page 36

    36 © 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com rev. Date 111714 1. Insert the elastic cord through the top eyelet of each of the 4 turnbuckles as shown in pic- tures 1 & 2. 2. Pull one of the ends of the cord through one of the holes on the cable lock ...

  • Page 37

    Rev. Date 111714 © 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com 37 technical support for installation assistance, application questions, technical sales support & any other inquiries, please contact our technical support team at (866) 668-3247..

  • Page 38

    38 © 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com rev. Date 111714.

  • Page 39

    Rev. Date 111714 © 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com 39 90-30015-10 revised march, 2012 warranty information please reference page 39 for the full 12-year limited warranty. Then, please fill out the bottom portion and send to macroair. The addr...

  • Page 40

    40 © 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com rev. Date 111714 warranty information please fill out the bottom portion and send to macroair. Keep the of this page and keep the top portion for your records. Macroair technologies, inc. 794 south allen s...

  • Page 41

    Rev. Date 111714 © 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com 41 12-year limited warranty macroair 12-year service life prorated limited warranty macroair technologies, inc. Warrantor: the warrantor for the limited warranties set forth herein is macroai...

  • Page 42

    42 © 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com rev. Date 111714.