    879 maple street l contoocook, nh 03229 phone 603.456.2011 l fax 603.456.2012 www.Madgetech.Com l info@madgetech.Com octtemp2000 red 485 dark blue pantone 289 light blue 58% of pantone 289 data logger manual.

  • Page 2: Data Logger Manual

    Data logger manual page 1 table of contents overview .............................................................................................. 2 other documentation ..................................................................... 2 contacting us ...............................................

  • Page 3: Madgetech  Octtemp2000

    Page 2 madgetech octtemp2000 overview other documentation other documents which may be of interest to you are the software operating manual and data logger quick start guide. To obtain the most current versions of both of these documents please visit our website (www.Madgetech.Com). Contacting us fo...

  • Page 4: Data Logger Manual

    Data logger manual page 3 introducing the octtemp2000 device overview ok key cancel key up/down directional keys left/right directional keys status leds 9-12vdc input communications port directional key pad channel inputs lcd mounting holes ok key cancel key keypad functions.

  • Page 5: Madgetech  Octtemp2000

    Page 4 madgetech octtemp2000 display overview status indicators battery power (full, half-full, empty) memory remaining (empty, half-full, full) device is running device is stopped delay start push-button (manual) start device reset has occurred external power present status indicators screen title ...

  • Page 6: Data Logger Manual

    Data logger manual page 5 specifications internal temperature channels range: -20 to +60°c resolution: 0.1°c accuracy: ±0.5°c (0 to +50°c) thermocouple channels types: j, k, t, e, r, s, b, and n connection: female sub-minature (smp) cold junction compensation: automatic, based on internal channel ma...

  • Page 7: Madgetech  Octtemp2000

    Page 6 madgetech octtemp2000 calibration digital calibration through software. Calibration date automatically recorded within device. Nist traceable certificate available. Power supply primary source: 9v lithium or alkaline battery, user replaceable secondary source: 7.5 - 24v dc external, 100ma max...

  • Page 8: Data Logger Manual

    Data logger manual page 7 device functions channel options each of the octtemp2000’s channels have several options that are configurable by the user through the device’s display screen menus and the software. Show or hide channels on the home screen the user may choose to either show or hide channel...

  • Page 9: Madgetech  Octtemp2000

    Page 8 madgetech octtemp2000 change channel display size channels may be viewed in a number of different sizes. The smallest size allows for an overview of several channels at once, while the largest gives at-a-glance access to one or two channels. Small font medium font large font to change channel...

  • Page 10: Data Logger Manual

    Data logger manual page 9 change channel units channels can be customized to display readings in a variety of convenient units. Units available for selection will vary according to channel type. Note: changing display units will not affect logged data. To change channel display from the home screen ...

  • Page 11: Madgetech  Octtemp2000

    Page 10 madgetech octtemp2000 statistics statistical information is generated based on the data measured by each channel. View channel statistics minimum, maximum, and average values are calculated for each channel and displayed in the statistics screens. To view channel statistics from the home scr...

  • Page 12: Data Logger Manual

    Data logger manual page 11 time and date information current time and date information is available on the lcd. System time is automatically synchronized with your computer’s clock. To view time and date information from the home screen : 1. Press to enter the main menu 2. Use to highlight clock 3. ...

  • Page 13: Madgetech  Octtemp2000

    Page 12 madgetech octtemp2000 device menus device status menu information such as current recording status, reading rate, stop date and time, and calibration information can be found in the device status menu. To access the device status menu from the home screen : 1. Press to enter the main menu 2....

  • Page 14: Data Logger Manual

    Data logger manual page 13 cal date – date of last device calibration cal due – date device is due for recalibration note: it is important to keep your device properly calibrated to ensure accurate readings. Contact madgetech for further information regarding calibration services. Device setup menu ...

  • Page 15: Madgetech  Octtemp2000

    Page 14 madgetech octtemp2000 display – options for display visibility use to select auto - display turns off after two minutes of inactivity on - display always on backlight – options for use of display backlight use to select auto - backlight turns off after five seconds of inactivity on - backlig...

  • Page 16: Data Logger Manual

    Data logger manual page 15 software features this section details several features of the data logger software that are particularly useful with the octtemp2000 device. For further information regarding the software, please consult the data logger software manual available at www.Madgetech.Com. Enab...

  • Page 17: Madgetech  Octtemp2000

    Page 16 madgetech octtemp2000 notice that disabled thermocouple and ambient channels appear grayed-out on the device detail screen..

  • Page 18: Data Logger Manual

    Data logger manual page 17 name channels each channel can be given an unique name for easy identification. Channel names are visible on the lcd and are used throughout the software and data files. To name channels in the software: 1. In the device drop down menu select identify device and read statu...

  • Page 19: Madgetech  Octtemp2000

    Page 18 madgetech octtemp2000 change device id each octtemp2000 can be given a device id allowing for easy identification among multiple devices. Device ids are displayed on the home screen of the lcd and are used throughout the software and data files. To change device id in the software: 1. In the...

  • Page 20: Data Logger Manual

    Data logger manual page 19 battery information battery replacement this product does not have any user-serviceable parts except the battery which should be replaced periodically. The battery life is affected by battery type, ambient temperature, sample rate, sensor selection, off-loads and lcd usage...

  • Page 21: Madgetech  Octtemp2000

    Page 20 madgetech octtemp2000 computer interface fully insert the male connector of the ifc200 interface cable into the female receptacle of the data logger. Fully insert the female usb connector into the usb. (please see the data logger software manual for further information.) *warning: install dr...

  • Page 22: Data Logger Manual

    Data logger manual page 21 warranty products manufactured by madgetech, inc., are warranted against defective material and workmanship for a period of one year, starting from the date of shipment. In the event that a madgetech product is found to be defective, madgetech will repair or replace the pr...

  • Page 23: Madgetech  Octtemp2000

    Page 22 madgetech octtemp2000 terms and conditions all products furnished by madgetech, inc. (“seller”) shall be in accordance with the following terms and conditions unless otherwise stated in writing: these terms and conditions (“terms and conditions”) govern (a) all sales quotations and sales of ...

  • Page 24: Data Logger Manual

    Data logger manual page 23 warranties and covenants, expressed or implied, in regard thereto. Except for the express limited warranty set forth in this section, seller does not make and hereby disclaims any and all other representations and warranties of any kind whatsoever, whether expressed, impli...

  • Page 25: Madgetech  Octtemp2000

    Page 24 madgetech octtemp2000 employees, who must use the software only as specified above; (ii) modify the software or merge it with another program; (iii) reverse engineer, disassemble, decompile, or make any attempt to discover the source code of the software; (iv) translate or create derivative ...