7. TROUBLESHOOTING
Caution: never perform repair when the appliance is connected. Disconnect the power supply before cleaning
or servicing this unit.
Problem (s)
Solution(s)
The power supply is
damaged
•
If the power supply unit is damaged, please contact an Authorized Service Center
The motor does not work
•
Check the electrical connection from the hood to the electrical system.
•
Make sure the wirings between the switch board and control board are connected
properly.
•
Check that the switch wires are correctly connected to the control panel
The lights work, but the
fan does not turn, it
seems stuck or vibrates
•
It is possible that the fan is clogged or it touches the bottom of the hood. Place a
service call.
•
The motor may be defective, place a service call.
•
The thermal protection system detected overheating of the motor and cut the electrical
circuit. In this case, the motor will restart when the thermal protection system is cooled
(about 10 minutes)
The hood is not venting
out properly
•
Verify the distance between the lower part of the hood and the cooking surface
(making sure it is between 21
"
and 24
"
).
•
Reduce the number of transitions, elbows and turns
•
Make sure that all connections and duct works are sealed with aluminum duct tape.
•
The wind from a window or a door nearby open interferes with the functioning of the
hood. Close all windows and doors to eliminate draughts.
•
The direction of duct opening is wrong. It most open towards the exterior.
•
Check the size of the ducts; they must be the suggested size.
The light bulb does not
work
•
Check whether the bulb is sufficiently screwed.
•
Change the light bulbs to check whether the problem is due to a defective bulb.
For any other questions or to contact our After sales/ Authorized service Centre
AGI SERVICE
450.963.6710/1.888.651.2534
www.agiservice.ca
8. WARRANTY
This product is guaranteed, parts and service, in the event of default for a period of one (1) year from the date of
purchase. This warranty is applicable only to residential use and will not be granted for usage in commercial or
institutional facilities.