DEHUMIDIFIER CONTROL PANEL
Other features
Bucket Full Light
Glows when the bucket is ready to be
emptied, or when the bucket is removed
or not placed in the proper position.
When frost builds up on the evaporator coils, the
compressor will cycle off and the fan will continue
to run until the frost disappears.
Auto Defrost
Wait 3 minutes before resuming operation
After the unit has stopped, it can not be restarted
immediately. This is to protect the unit from mal-
function. Operation will automatically start after
3 minutes.
Setting the Timer
When the unit is on, first press the TIMER
button, the TIMER OFF indicator light
illuminates. It indicates the Auto Stop
program is initiated. Press it again for the
TIMER ON indicator light to come on to
indicate the Auto Start is initiated.
Press or hold the UP or DOWN buttons to
change the Auto timer by half hour incre-
ments, up to 10 hours, then at 1 hour
increments up to 24 hours. The control
will count down the time remaining until
the start time.
The selected time will register in 5 seconds
and the system will automatically revert
back to display the previous humidity setting.
When the Auto start & Auto stop times are
set, within the same program sequence,
TIMER ON OFF indicator lights both turn on
to show that the TIMER ON and OFF program
is active.
Turning the unit ON or OFF at any time or
adjusting the timer setting to 0.0 will cancel
the Auto Start/Stop function.
When LED display window displays the
code P2, the Auto Start/Stop function will
also be cancelled.
When the unit is off, first press the Timer
button for the TIMER ON indicator light
to come on to indicate the Auto Start
program. Press again to stop the Timer
and initiate Auto Stop.
Check filter feature
The system starts to count the time once the fan
motor operates. The check filter feature will be lit
when the accumulated operation time achieves
250 hours or more. The Reset light(Clean filter
indicator light) flashes until the filter is cleaned.
Press the Filter button to reset and stop the blinking filter
and Reset light(Clean filter indicator light).
10
Display
Shows the set % humidity level from 35% to 85% or auto
start/stop time (0~24) while setting, then shows the actual
( 5% accuracy) room % humidity level in a range of 30%
RH(Relative Humidity) to 90%RH(Relative Humidity).
Error Codes and Protection Code:
AS- Humidity sensor error--Unplug the unit and plug it back
in. If error repeats, call for service.
ES- Temperature sensor error-- Unplug the unit and plug it
back in. If error repeats, call for service.
P2- Bucket is full or bucket is not in right position-- Empty
the bucket and replace it in the right position.
P1- Unit has frost build up-- Allow the unit to run on
AUTO DEFROST mode.
Auto Shut Off
The dehumidifier shuts off after 30 seconds when
the bucket is full, or when the bucket is removed
or not placed in the proper position.When the set
humidity is reached, the unit will shut off auto-
matically. For some models,the fan motor will
continue operating.
Auto-Restart
If the unit shuts off unexpectedly due to a power outage,
it will restart with the previous function setting automatically
when the power resumes.
EC- Unit malfuction--
for
Please make sure whether the
environment temperature is suitable for the stated
temperature in the manual or not. If not, please operate
the unit under the stated temperature. If the environment
temperature is normal for the stated temperature, please
call service.
6
PARTS IDENTIFICATION
Power Cord and plug
Drain hose outlet
Band(Used only when
storing the unit.)
Front
Rear
Air outlet grille
Caster wheels
Parts identification
Fig.2
Fig.3
Air filter (behind the grille)
Control panel
Air intake grille
Water bucket
1
2
3
4
5
1
2
3
4
NOTE: All pictures in the manual are for
explanation purposes only.The actual
design of your unit may be slightly different,
but the operations and
functions are the same.
5
1
2
3
4
Accessories:
Drain hose(1pc)
Screw(2pc)
Adapter A(1pc)
6
6
Handle (both sides)
1
2
3