Magnavox W-08CR Owner's Manual

Manual is about: Window/wall-type room air conditioner

Summary of W-08CR

  • Page 1

    Before using this product, please read the instructions carefully and keep for future reference. Model: w-08cr w-10cr w-12cr for any service needs, call 1-855-368-8606 owner's manual.

  • Page 2: Contents

    Contents 1 1. Safety precautions ...................................................................2 2. Important safety instructions ............................................4 7. Normal operating sounds ....................................................17 inside you will find many helpful tip...

  • Page 3: Safety Precautions

    To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation may cause harm or damage. The seriousness is classified by the warning symbols below. Safety precautions this symbol indicates the possibility of death or serious injur...

  • Page 4

    ! Caution when the air filter is removed do not touch the exposed metal parts. Y cause an injury. Do not clean unit when power is on as it may cause fire and electric shock, cause an injury. Operation with windows opened may cause water when the unit is cleaned, switch off, and turn off the circuit ...

  • Page 5

    Important safety instructions be sure the s adequate for the model you have chosen. This information can be found on the serial plate, which is located on the side of the cabinet and behind the grille. Be sure the air conditioner is properly grounded. To minimize shock and fire hazards, proper groun...

  • Page 6: Air Conditioner Features

    Air conditioner features before you begin, familiarize yourself with the control panel on the unit and the remote control as shown below and refer to the symbols for the functions you desire. The unit can be controlled by either the unit controls or with the remote control. Electronic control operat...

  • Page 7

    To change temperature setting: temp temp timer timer on off sleep check filter timer auto auto press to raise do this: press to lower press or hold either left( ) button until the desired temperature display. This temperature will be automatically maintained anywhere between 62 f(17 c) and 86 f(30 c...

  • Page 8

    During this function, the display will show the actual room temperature, not the set temperature as in the cooling mode. To use the energy saver feature: press the button auto cool dry fan low auto med high clean air fan mode follow me energy saver on/off do this: this function is available on cool ...

  • Page 9

    Temp temp timer timer on off sleep check filter timer auto cool dry fan low auto med high clean air timer: auto start/ stop feature: press timer button do this: air conditioner features(continued) note:(timer button) temp temp timer timer on off sleep check filter timer auto cool dry fan low auto me...

  • Page 10

    Air conditioner features(continued) follow me feature: (only on some models) light flashing auto cool dry fan low auto med high clean air fan mode follow me energy saver on/off note: to activate the follow me feature, point the remote control towards the unit and press the follow me unit does not re...

  • Page 11: Installation Instructions

    Levers air direction interior wall wooden windows window sill air directional louvers throughout the room as needed. Pivot horizontal move the levers from side to side until the desired installation instructions 23 to 36 inches(58.4cm to 91.4cm) (see fig.D). Lower sash must open sufficiently to allo...

  • Page 12

    C: align the hole in the top rail with those in the top of the unit as shown in fig.F fig.F fig.G d: secure the top rail to the unit with the 3/8 screws as shown in fig.G. Note: for safety reasons, all four(4) screws must be securely fastened. ,, how to install note: top rail and sliding panels at e...

  • Page 13

    12 keep a firm grip on the air conditioner, carefully place the unit into the window opening so the bottom of the air conditioner frame is against the window sill (fig.4). Carefully close the window behind the top rail of the unit. 2 fig.4 extend the side panels out against the window frame (fig.5)....

  • Page 14

    13 to secure lower sash in place, attach right angle sash lock with 3/4" (19mm) or 1 screw as shown(fig.8). /2" (12.7mm) 6 cut and insert it in the space between the upper and lower sashes (fig.9). Window sash seal foam 7 fig.9 if ac is blocked by storm window add wood as shown in fig.10, or remove ...

  • Page 15: Cleaning and Maintenance

    Cleaning and maintenance clean your air conditioner occasionally to keep it looking new. Be sure to unplug the unit before cleaning to prevent shock or fire hazards. Caution air filter cleaning the air filter should be checked at least once a month to see if cleaning is necessary. Trapped particles ...

  • Page 16: Troubleshooting Tips

    Before calling for service, review this list. It may save you time and expense. This list includes common problems that may not be the result of defective workman-ship or materials in this appliance. Troubleshooting tips 15 problem solution air conditioner does not start air from unit does not feel ...

  • Page 17

    16 problem solution air conditioner turns on and off rapidly noises coming from the unit when cooling - a dirty air filter may be obstructing the cool air. Clean the filter as instructed on the ‘care and cleaning section’ of this manual. - in cases where the outside temperature may be extremely high...

  • Page 18: Normal Operating Sounds

    Normal operating sounds sound of rushing air at the front of the unit, you may hear the sound of rushing air being moved by t he fan. High pitched chatter sound high efficiency compressors may have a high pitched chatter during the cooling cycle. Gurgle/hiss sound gurgling or hissing noise may be he...

  • Page 19

    The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details. Magnavox and smart. Very smart are registered trademarks of koninklijke philips n.V. And are used under license from koninklijke philips n.V..