Magnescale SQ10 SERIES Instruction Manual - page 2
6. Affi
x the scale while making contact with two or more
parallel pins.
Using your fi ngers, fi x the scale in place by fi rmly pressing
down the 30-mm section of the peeled backing paper.
Make contact
Make contact
7. Peel off the backing paper to the position where the next
parallel pin is reached.
8. Affi
x the scale while making contact with the parallel pin
and being careful that fi rm contact is maintained.
9. Repeat steps 7 and 8 until the entire length of the scale is
affi
xed.
10. Press down the entire length of the scale with your
fi ngers.
Installation Procedure
Preparation
Make holes on the scale installation surface for inserting
parallel pins so that positioning can be performed.
• Th
e parallelism of the holes with respect to the machine
guide should be 50 μm or less. (See the Installation
Dimensional Diagram.)
Installation
1. Leave the scale near the machine where it will be installed
for one hour so that the scale can adjust to the machine
temperature.
2. Use a clean cloth dipped in alcohol to wipe off any dirt,
dust or oil from the installation surface.
3. Insert the parallel pins.
Parallel pin
Parallel pin
insertion hole
1000 mm or less
Scale installation surface
0.05
M
M: Machine guide
4. Check the orientation of the scale. Aligh the scale so that
the SmartSCALE marks on the scale and head are facing
in the same direction.
SmartSCALE marks
5. Peel
off about 30 mm of the backing paper.
Backing paper
Peel off about 30 mm
Peel off to the position where
the next parallel pin is reached
Specifi cations
Operating temperature range : 0 to 50 °C
Storage temperature range
: –20 to 60 °C
Mass :
(Eff ective length × 0.22) + 8 g
Installation Dimensional Diagram
Align the SmartSCALE mark on the scale and head so that they are facing the same direction.
Unit : mm
M : Machine guide
0.05
0.05
0.04
8
SQ10
Scale
A
Roll: ±0.3°
A
0.04 A
0.05 A
B
M
Effective length mark
Parallel pin
B
0.28
B
0.28
Head unit
(9.385)
21
16
Yaw: ±0.5°
2.5±
0.8
Offset
Effective length
Total length = Effective length + 40
20
(20)
Pich: ±0.3°
0.185±0.1
Clearance
2
33
Center mark
I
4.7
3.9
2.5
28
2.5
11
(16)
2 × M3 depth6
0.145
(Double-sided tape thickness)
1.2
1
Measurement
detection
position
10.5
Cable length
Reference point
position mark