Magnetic Autocontrol VEK CN1 Operating Instructions Manual

Manual is about: DIGITAL COUNTER

Summary of VEK CN1

  • Page 1

    1 / 1 operating instructions digital counter vek cn1 version 2002_03.

  • Page 2

    Note: the manufacturer reserves the right to modify, without prior notice, the technical specifications in order to accommodate the latest technical developments. Magnetic automation corp. Will provide information on the status of existing operating instructions and on any alterations and extensions...

  • Page 3

    3 / 3 table of contents 1 functional description_________________________________________________________ 4 1.1 general __________________________________________________________________________ 4 1.2 display and setup_________________________________________________________________ 5 1.2.1 user int...

  • Page 4

    1 functional description 1.1 general 4-pin plug for counting inputs ↓ ↑ optional 4-pin plug for rs485-interface the digital counter vek cn1 is designed to control small to medium car-parks. Four (4) counting inputs are used to accept outputs from loop detectors and/or traffic gate controllers. The c...

  • Page 5

    5 / 5 1.2 display and setup 1.2.1 user interface buttons the vek cn1 digital counter is adjusted with the three (3) user interface buttons located on top of the unit. The display shows the current menu and status of the setup. The buttons have following functionality: button function m short next me...

  • Page 6

    1.3 base menu – setting the operating modes the base menu contains all settings for the different operating modes. The existing counts can be displayed, modified and reset to original stage. The relay output can manually be set to “free” or “occupied”. Display menu setting 1234 normal operation, cur...

  • Page 7

    7 / 7 1.3.3 display and counter reset the inputs can individually count to up to 9,999,999 and can individually be displayed or if necessary reset to zero. Display status setting 1234 normal operation m 2 x short → cnk1 = input counter 1 : m 5 x short → cnk4 = input counter 4 cnk1 ...4 1234 alternat...

  • Page 8

    1.4 system menu – installation specific settings in the system menu all installation specific settings can be made. Display menu item setting 1234 normal operation m long → display sys = system menu alternating shows program version; for example a02 s oc 1234 alternating switch threshold 0...9999 hy...

  • Page 9

    9 / 9 1.4.1 operating modes/ switching point the digital counter can be set to operating mode “open space count” or " passing vehicle count“ . The two options can be selected by setting the count threshold to: threshold = 0 (default) → mode “open space count” see 1.4.1.1 threshold = 1 = 1..9999 → mo...

  • Page 10

    1.4.3 upper count level and lower count level the maximum and minimum range of the total count can be adjusted using this menu. This enables the counter to automatically adjust the total in case the maximum or minimum level is reached to prevent a wrongful count to continue. The default is 9999 for ...

  • Page 11

    11 / 11 1.4.4 display / input settings independent from each other the inputs can be set to: • incrementing • decrementing, • reset count • no function display status setting 1234 normal operation m long → sµs → s oc m 4 x short → inp1 = function input 1 inp1 ...4 alternating add sub res no.F displa...

  • Page 12

    1.4.6 power save mode if the power save mode is activated the display turns if there was no activity on the user interface for more then 30sec. The count function continuous to run in the background. The power save mode can be adjusted using following menu: display status setting 1234 normal operati...

  • Page 13

    13 / 13 2 installation instructions 2.1 input voltage all inputs are provided with opto couplers. To activate the inputs you can either use the internal switching voltage or use an external supply. When using an external supply you must first change the internal jumper setting of the control board. ...

  • Page 14

    2.2 reset input (optional) using one of the inputs as count reset input all counts can be reset to 0 when a signal is applied. According to the relay output setting the relay switches to “open” or “occupied”. The reset does not effect the adjusted parameters..

  • Page 15

    15 / 15 3 technical data measurements 3” (79mm) x3/4” (22,5mm) x3.50” (90 mm) (hxwxl without plug) protection class ip 40 power supply 12v to 24v ac/dc ± 10% power consumption max. 2 w operating temperature -20 °c to +70 °c storage temperature -40 °c to +70 °c humidity max. 95 % non-condensing count...