Magnum CSW1012 Owner's manual

Other manuals for CSW1012: Owner's Manual
Manual is about: Pure Sine Wave Inverter CSW Series

Summary of CSW1012

  • Page 1

    Owner’s manual csw series pure sine wave inverter.

  • Page 2

    © 2015 sensata technologies i thank you from all of us at sensata technologies for purchasing this csw series inverter. The csw series includes the csw412, csw1012 and csw2012 inverters; all under the magnum-dimensions brand from sensata technologies. We understand that you have many purchasing opti...

  • Page 3

    Ii © 2015 sensata technologies important product safety instructions this manual contains safety instructions that must be followed during the installation and operation of this product. Read all instructions and safety information on the inverter and in this manual before installing or using. Safet...

  • Page 4

    © 2015 sensata technologies iii table of contents 1.0 introduction ............................................................................. 1 1.1 features - csw1012 and csw2012 ............................................. 1 1.2 features - csw412 ...................................................

  • Page 5

    Iv © 2015 sensata technologies list of figures figure 1-1, front panel features (csw1012 and csw2012) .................... 1 figure 1-2, back panel features (csw1012).......................................... 2 figure 1-3, back panel features (csw2012).......................................... 2 fig...

  • Page 6: 1.0 Introduction

    © 2015 sensata technologies 1 1.0 introduction 1.0 introduction congratulations on your purchase of the csw series pure sine wave inverter. The csw series includes the csw412, csw1012 and csw2012 inverters; under the magnum-dimensions brand from sensata technologies. The csw series inverters are “pu...

  • Page 7

    2 © 2015 sensata technologies 1.0 introduction the back panels of the csw1012 and csw2012 inverters are equipped with the following features (see figure 1-2 and figure 1-3): 8. Cooling fan(s) – an intake cooling fan that automatically turns on when the inverter’s internal temperature rises above 122...

  • Page 8

    © 2015 sensata technologies 3 1.0 introduction figure 1-4, front panel features (csw412) 2 1 3 4 5 6 1.2 features - csw412 the csw412 inverter is equipped with the following front panel features (see figure 1-4): 1. Power indicator – an at-a-glance led that lights green when the inverter is on. (see...

  • Page 9

    4 © 2015 sensata technologies 1.0 introduction figure 1-5, back panel features (csw412) 12 8 11 9 10 the back panel of the csw412 inverter is equipped with the following features (see figure 1-5): 8. Cooling fan – an intake cooling fan that automatically turns on when the inverter’s internal tempera...

  • Page 10: 2.0 Installation

    © 2015 sensata technologies 5 2.0 installation 2.0 installation review this section and all safety instructions before proceeding with the installation of your inverter. Warning: installations should be performed by qualified personnel, such as a licensed or certifi ed electrician. The installer det...

  • Page 11

    6 © 2015 sensata technologies 2.0 installation figure 2-1, basic system diagram ac out csw-ts15 transfer switch csw series inverter ac loads (15a max) dvd tools tv ac sub-panel ac outlet dc disconnect fuse battery bank dc ground (vehicle chassis, dc ground bus, or engine negative bus) ac main panel ...

  • Page 12

    © 2015 sensata technologies 7 2.0 installation figure 2-2, rv oem system diagram ac main panel (branch circuit breaker to transfer switch: 15a max) ac in ac out ac source (120vac, 60 hz sinewave) csw-ts15 transfer switch csw series inverter notes: the nec requires overcurrent protection for wiring a...

  • Page 13

    8 © 2015 sensata technologies 2.0 installation 2.2 locating and mounting the inverter warnings: • do not mount the inverter near any flammable or combustible fluid or components. • provide adequate clearance/ventilation to the inverter. Do not cover or obstruct any air vent openings and/or install i...

  • Page 14

    © 2015 sensata technologies 9 2.0 installation figure 2-4 csw412 dimensions figure 2-3, approved mounting positions for rv installation: mount flat on a horizontal surface only for indoor use: flat on a horizontal surface (right side up or upside down). Dc terminals to the right, left or the top. No...

  • Page 15

    10 © 2015 sensata technologies 2.0 installation figure 2-5 csw1012 dimensions figure 2-6 csw2012 dimensions top 10.3’’ (26.2 cm) 6.3’ ’ (16.1 cm) 6.9’ ’ (17.5 cm) 12.6’’ (32.1 cm) front (ac side) back (dc side) 3.4’’ (8.4 cm) top 13.4’’ (34 cm) 8.5’ ’ (21.6 cm) 9.1’ ’ (23 cm) 16.5’’ (41.9 cm) front ...

  • Page 16

    © 2015 sensata technologies 11 2.0 installation 2.3 wiring the inverter – general requirements this section describes the requirements and recommendations for wiring the csw series inverter. Before wiring the inverter, carefully read all instructions. Warning: wiring should meet all local codes/stan...

  • Page 17

    12 © 2015 sensata technologies 2.0 installation 2.4 dc wiring this section describes the inverter’s required dc wire sizes, the recommended disconnect/overcurrent protection, and how to make the dc connections to the inverter and the battery bank. Warning: even though dc voltage can be regarded as “...

  • Page 18

    © 2015 sensata technologies 13 2.0 installation 2.4.1 dc wire sizing it is important to use the correct sized dc wire to achieve maximum effi ciency from the system and to reduce fi re hazards associated with overheating. Always keep your wire runs as short as practical to prevent low voltage shutdo...

  • Page 19

    14 © 2015 sensata technologies 2.0 installation 2.4.2 dc overcurrent protection for safety reasons and to comply with electrical code regulations, dc overcurrent protection must be provided as part of the installation. The dc overcurrent protection device must be installed in the positive dc cable l...

  • Page 20

    © 2015 sensata technologies 15 2.0 installation 2.4.5 wiring the battery bank warning: lethal currents will be present if the positive and negative cables attached to the battery bank touch each other. During the installation and wiring process, ensure the cable ends are insulated or covered to prev...

  • Page 21

    16 © 2015 sensata technologies 2.0 installation 2.4.7 wiring the inverter to the battery bank caution: the inverter is not reverse polarity protected—if the positive terminal of the battery is connected to the negative terminal of the inverter and vice versa, severe damage to the inverter will occur...

  • Page 22: Battery

    © 2015 sensata technologies 17 2.0 installation figure 2-8, dc cable to inverter’s dc terminals dc cable with ring lug inverter’s dc + terminal m6-1.0 hex nut caution: ensure nothing is placed between the dc terminal and the ring lug. Csw1012 inverter lock washer #12 flat washer battery dc cable wit...

  • Page 23

    18 © 2015 sensata technologies 2.0 installation 2.5.2 gfci function test use the steps below to periodically test the gfci to ensure it is functioning properly. 1. Turn the inverter on. 2. Plug a small ac load (e.G., 40w light bulb) into the gfci’s outlet. 3. Check that the ac load is on (i.E., the ...

  • Page 24: 3.0 Operation

    © 2015 sensata technologies 19 3.0 operation 3.0 operation when the inverter is properly connected to batteries and turned on, the direct current (dc) from the batteries is transformed into a pure sine wave alternating current (ac). This ac is similar to the voltage provided by your utility and is u...

  • Page 25

    20 © 2015 sensata technologies 3.0 operation 3.2 csw1012 and csw2012 operation the csw1012 and csw2012 inverters use a front panel that contains a power/select button, a status indicator, a digital display for viewing system status, a remote port, a usb port, and a gfci ac output receptacle. Turning...

  • Page 26

    © 2015 sensata technologies 21 3.0 operation 3.3 understanding loads the inverter can power most loads within its power rating, however, there are special conditions that can cause a load to behave differently than expected. Following are some common problems encountered when using this inverter. Us...

  • Page 27: 4.0 Troubleshooting

    22 © 2015 sensata technologies 4.0 troubleshooting 4.0 troubleshooting use table 4-1 to troubleshoot your inverter. For csw1012 or csw2012 inverters, also use table 4-2 to view the unit’s digital display to determine what condition triggered the error/warning code and what corrective action is neede...

  • Page 28: 5.0 Specifi Cations

    © 2015 sensata technologies 23 5.0 specifi cations 5.0 specifi cations table 5-1, csw series specifi cations model csw412 csw1012 csw2012 electrical specifi cations continuous power 1 400 w 1000 w 2000 w surge power (peak) 2 800 w 2000 w 4000 w ac output voltage (12.5v) 120 vac rms ± 5% ac output cu...

  • Page 29: 6.0 Limited

    24 © 2015 sensata technologies 6.0 service and warranty info 6.0 limited warranty sensata technologies warrants the csw series inverter to be free from defects in material and workmanship that result in product failure during normal usage, according to the following terms and conditions: 1. The limi...

  • Page 30

    Pn: 64-0063 rev c magnum-dimensions products manufactured by: sensata technologies 2211 west casino rd. Everett, wa 98204 phone: 425-353-8833 fax: 425-353-8390 web: www.Magnum-dimensions.Com.