Magus MALP0400LWLR User Manual - page 3
User manual
Product overview
1.3 Control panel description
1. Volume level:
High level,
alarm volume more than
90dB; Low level, alarm
volume more than 80dB;
Default level is high level
2. Power
switch:
'ON'
for
power on, 'OFF' for power off
3. DC output port:
DC12V
linked external power output
port when alarming
4. AC output port:
AC220V
linked external power output
port when alarming(Attention:
when connect or disconnect
this port, please make sure to
shut off the panel power and no naked wire in case
of electronic shock)
5. Disarm button:
Alarm stop when press this button.
6. Emergency button:
Immediately alarming when press this
button
7. Tamper switch:
Alarming immediately once panel
1.4Detector description
Mode option: Detector have two kinds of working pattern,
Power saving mode and Standard mode. As shown in
picture, Insulation cap plugged in number 1, mode is power
saving;Plugged in number 2, mode is standard. Mode
change must be reenergized(Remove the battery, reload
after 30 seconds)
User manual
Product overview
A. Power-saving pattern features:
Continuous body movement won't effect
the alarm after detectors triggered and
alarmed to control panel. If the detector
first triggered and no body movement
detected over 10 seconds, alarm signal
would be sent again to control panel. In
the power
B. Standard pattern features:
Detector first triggered and alarming up
to 5 minutes, and detector won't detect any infrared movement
during this 5 minutes. Detector will send alarm signal to
control panel again if triggered after 5 minutes or more. The
factory default mode is standard mode.
1. Pulse option:
Insulation cap inserted in number one, it's
double pulse mode, infrared sensitivity is low; Insulation cap
plugged in number two, it's single pulse, infrared sensitivity is
high. Factory default mode is single pulse.
2. Sensitivity level option:
Detector have 3 levels for
sensitivity, H/M/L levels. 8-12m detecting range for
'H' level, 6-8m 'M' level, 4-6m for 'L' level. Factory
default level is 'H' level.
3. Power switch:
Power switch turn to 'ON', detector
works;
Turn to 'OFF', detector stop working. The detector
will send alarm to panel when power on or power off.
4. Infrared sensor:
Don't touch sensor surface with your hand.
If any dirt on the surface, you can clean it with 75% alcohol
cotton.