6.6 Adjust the amount of coffee
In both dosing units (cups and liters) the amount of coffee can be
adjusted with the +/- buttons prior to grinding.
Press the +button (pos.4) to increase the amount
of ground coffee (full cups or 0.1 liters).
Press the -button (pos.5) to decrease the amount
of ground coffee.
See table on the right for dosing suggestions.
6.7 Start/stop the grinder
Press the START button (pos.3) to start the grinding process. The
grinder stops automatically after grinding the pre-set amount.
To manually stop the grinder before the pre-set amount has been
ground press the START button again.
Note: The remaining time of the discontinued
grinding process will not be saved.
Overview - Dosing Suggestions
Basic definitions by the manufacturer:
•
The approximate grind speed of the FCG 2.0 at a medium
filter coffee grind size adjustment is 5.5 g/s.
•
The dosing parameters of the FCG 2.0 have been calibrated
to grind coffee to
“SCAE GOLD CUP Standard”
3)
, i.e. coffee-
to-water-ratio of 55g/l.
•
One cup has been defined as 225ml (7.6oz).
•
The maximum doses are 14 cups or 2.2 liters respectively.
Dosing examples:
Dosing Unit
cups
liters
Amount
Appr. Time
-
0.1
5.5 g
1.0 s
1
(0.225)
10 g
1.8 s
-
0.5
27.5 g
5.0 s
4
0.9
50 g
9.0 s
-
1.0
55 g
10 s
-
1.6
80 g
14.5 s
8
1.8
95 g
17.3 s
-
2.2 (max)
120 g
21.8 s
14 (max)
-
170 g
31.0 s
G A S T R O N O M I E M Ü H L E N | H O R E C A G R I N D E R
10
3) For more information about this standard, go to www.scae.com