Mahlkönig K30 TWIN Operating Instructions Manual - page 15
H O R E C A
| G A S T R O G R I N D E R
Main Menu
Sub Menu
PROG.
press
7) TEST
7-1) INPUT, DIP
SWITCH, FAN
7-2) TRIAK, RELAY
CURRNET
7-3) BUTTONS
7-4) DISPLAY
SIC SW1 SW2 MC1
OFF OFF OFF OFF
F1 (HZ) F2 (HZ)
ON 120 OFF 0
GR1=OFF RL=ON
I = 4.89A
right
press
right
press
right
press
right
press
PROG.
press
PROG.
press
PROG.
press
PROG.
press
PROG.
press
PROG.
press
7-5) POWER
SUPPLY
7-6) RS232
INTERFACE
right
press
right
press
right
right
KEYB=
(checking the function of the
buttons with numbers)
LCD
(testing all display dots)
LED
(testing all LED’s)
SIC:
Lid safety switch
SW1:
switch left grinder
SW2:
switch right grinder
MC1:
230V / 115V
ON:
Contact closed
activates / deactivates
the triak of the grinder
press
left
press
right
LCD
press
right
press
right
BUZZ
(testing the alarm)
press
right
activates / deactivates
the relayof the grinder
press
left
press
right
F1:
FAN 1
(HZ):
Frequency of F1
F2:
FAN 2
(HZ):
Frequency of F2
press
right
V-SUPPLY = 27.3V
testing the RS 232
Interface
right
right
for grinder 1
for grinder 2
or
for P5
press
for P6
left
press
for P8
right
press
for P7
left
press
for P9
right
END
Quick Manual K30 TWIN
Twin Espresso Grinder
Menu
right
press
only service menu
15