Maidaid Halcyon Evolution 501 Installation And User Manual - page 13
INSTRUCTION MANUAL FOR DISHWASHERS
UK
6.1 Settings
The following settings should only be configured by a qualified technician.
During installation or afterwards, a number of functions can be set in the dishwasher:
• Press
buttons
3 and 4 together for a few seconds, with the machine off and the door open;
PASSWORD 00 will appear on the display.
• Press
button
3 or 4 repeatedly until number “12” appears on the display.
• Press
button
1 to enter the menu, then use 1 again to scroll through the items.
• Activate, deactivate or adjust the function using buttons 3 or 4.
“Language”: Choosing the display language.
“Termostop”: Enables termostop. This function guarantees the ideal rinse temperature.
“Energy Saving”: Enables Energy saving. This function allows energy-savings to be made when
the appliance is switched on but not in use.
“Pre-heating”: Enables or disables the Preheating function (fast loading).
“Detergent pump”: Enables the detergent pump.
“Rinse aid pump”: Enables the rinse aid pump.
“Dosage Detergent g/l”: Sets the concentration of detergent, grams/litre.
“Dosage Rinse aid ajustment g/l”: Sets the concentration of rinse aid, grams/litre.
“Drain pump”: Enables the electric drain pump.
“Water hardness”: Sets the water hardness according to
the following table (Only for versions with incorporated water softener):
Measured
hardness
Water hardness
DF DH
n°
0
÷
20
0
÷
11
1
21
÷
30
12
÷
16
2
31
÷
40
17
÷
22
3
41
÷
60
23
÷
33
4
61
÷
70
34
÷
42
5
“Cycle for regeneration alarm with external softener”: Sets the number of regeneration cycles
for an external water softener.
“Cycle counter”: Resets cycle counter.
• To exit the menu and save the settings, press button 1 for a few seconds
Page 12 of 14