Main Heating Main Eco Elite Combi 25 User Manual

Manual is about: Condensing Central Heating Boiler

Summary of Main Eco Elite Combi 25

  • Page 1

    Main eco elite combi user guide condensing central heating boiler 25 - 30 en united kingdom please keep these instructions in a safe place. If you move house, please hand them over to the next occupier..

  • Page 2

    2 © baxi heating uk ltd 2015 natural gas main eco elite 25 combi erp g.C.N o 47 467 12 main eco elite 30 combi erp g.C.N o 47 467 13 © baxi heating uk ltd 2015 all rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means, or stored in any retrieval sy...

  • Page 3

    1.0 quick reference guide 3 © baxi heating uk ltd 2015 reset bar 0 1 2 3 4 reset bar 0 1 2 3 4 on/off/reset selector switch display central heating temperature control domestic hot water temperature control & pre-heat selector system pressure gauge off position the boiler will not operate. Central h...

  • Page 4

    2.0 troubleshooting 4 © baxi heating uk ltd 2015 start make sure the gas supply is turned on and check if other gas appliances are operating (e.G. Fire, cooker). If no gas, consult your supplier. Is the on/off/reset select switch in the ( ) position and the display lit ? Is the ( ) or ( ) light on a...

  • Page 5

    2.0 troubleshooting 5 © baxi heating uk ltd 2015 is the timer on and calling for heat ? Ensure timer is set for central heating on (see any instructions supplied with timer). Is the room thermostat (if fitted) set high enough ? 15 10 5 20 25 15 10 5 20 25 turn room thermostat to maximum setting (typ...

  • Page 6

    3.0 repressurising system 6 © baxi heating uk ltd 2015 bar 0 1 2 3 4 bar 0 1 2 3 4 3.1 central heating system pressure 1. The normal operating water pressure is when the needle is in the green section of the gauge, between 1 and 2.5 bar (fig. 1). If the pressure exceeds 3 bar (needle in the red sect...

  • Page 7

    4.0 ‘intelligent pre-heat’ feature 7 © baxi heating uk ltd 2015 operation of pre-heat 1. The boiler incorporates an intelligent pre-heat feature that will ensure optimum domestic hot water performance. 2. This features ‘learns’ the domestic hot water demand, and pre-heats the boiler primary circuit ...

  • Page 8

    5.0 clearances 8 © baxi heating uk ltd 2015 fig. 7 fig. 8 200mm min 780mm 450mm 5mm min 5mm min 450mm min for servicing purposes in operation 5mm min 5.1 for your safety note: only qualified persons are authorised to assemble, install and maintain the installation. 1. This appliance must have been i...

  • Page 9

    6.0 care of the boiler 9 © baxi heating uk ltd 2015 6.1 cleaning the outer case the painted panels should be wiped with a damp cloth and then dried completely. Do not use abrasive cleaning agents. 6.2 protection & precaution 1. The boiler incorporates an integral frost protection feature that will o...

  • Page 10

    7.0 legislation 10 © baxi heating uk ltd 2015 7.1 installation, commissioning, service & repair 1. This appliance must be install in accordance with the manufacturer’s instructions and the regulations in force. Read the instructions fully before installing or using the appliance. 2. In gb, this must...

  • Page 11

    8.0 warranty & service 11 © baxi heating uk ltd 2015 8.1 general to make sure your boiler warranty is activated and maintained, it is essential that the: 1. Benchmark checklist is completed by your installer 2. Warranty is registered with baxi 3. Boiler has an annual service please note that failure...

  • Page 12

    8.0 warranty & service 12 © baxi heating uk ltd 2015 annual service a service must be completed every 12 months from the date of installation to maintain your warranty. This service must be completed by one of the following: • a gas safe registered installer/engineer • baxi customer support; call us...

  • Page 13

    9.0 erp information 13 © baxi heating uk ltd 2015 9.1 product fiche - combination boilers product fiche for combination boilers space heating - temperature application main eco elite combi erp water heating - declared load profile seasonal space heating energy efficiency class water heating energy e...

  • Page 14

    9.0 erp information 14 © baxi heating uk ltd 2015 9.2 package fiche - boilers package fiche for boilers indicating the space heating energy efficiency of the package ad-3000743-01 % 1 ‘i’ 2 % + 3 % ( - ‘i’ ) x 0.1 = ± 4 % (‘iii’ x + ‘iv’ x ) x 0.9 x ( /100) x = + (1) a* = 0.95, a = 0.91, b = 0.86, c...

  • Page 15

    9.0 erp information 15 © baxi heating uk ltd 2015 9.2 package fiche - boilers (cont) package efficiency temperature control x main eco elite combi erp % temperature control y % the value of the mathematical expression: 294/(11 ʷ prated), whereby ‘prated’ is related to the preferential space heater. ...

  • Page 16

    9.0 erp information 16 © baxi heating uk ltd 2015 9.3 package fiche - combination heaters (boilers or heat pumps) package fiche for combination heaters (boilers or heat pumps) indicating the water heating energy efficiency of the package ad-3000747-01 % 1 ‘i’ 2 % (1.1 x ‘i’ - 10%) x ‘ii’ - - ‘i’ = +...

  • Page 17

    10.0 emergency 17 © baxi heating uk ltd 2015 gas tap heating flow, heating return and mains water inlet isolating valves fig. 10 in an emergency if a water or gas leak occurs or is suspected, the boiler can be isolated at the inlet valves as follows; 1. Using a suitable open ended spanner, turn the ...

  • Page 18

    12.0 notes 18 © baxi heating uk ltd 2015.

  • Page 19

    12.0 notes 19 © baxi heating uk ltd 2015.

  • Page 20

    7219661 - 01 (04/15) 0086 baxi customer support 0344 871 1525 opening hours monday - friday, 8.00am-6.00pm weekends and bank holidays, 8.30am-2.00pm please note calls may be recorded for training and monitoring purposes baxi.Co.Uk register now to activate your warranty: www.Baxi.Co.Uk/registration f...