Majestic 00DVBLN/PSC7 Installation And Operating Instructions Manual

Manual is about: DVBL7 Series

Summary of 00DVBLN/PSC7

  • Page 1

    743000 bldv 7 cover dvbl7 series direct vent gas fireplace 74d3001 1/10 rev. 5 models: 400dvbln/pv7;n/psc7 500dvbln/pv7;n/psc7 installation and operating instructions if the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal i...

  • Page 2

    74d3001 dvbl7 series gas fireplace contents important safety information ..................................... 3 code approval ............................................................. 4 product specifications................................................ 5 high elevations .......................

  • Page 3

    74d3001 3 dvbl7 series gas fireplace 4. Never install the fireplace • in a recreational vehicle • where curtains, furniture, clothing, or other flam- mable objects are less than 4" from the front, top, or sides of the fireplace • in high traffic areas • in windy or drafty areas 5. This fireplace rea...

  • Page 4

    74d3001 4 dvbl7 series gas fireplace important safety information & code approval continued from page 3 15. This appliance, when installed, must be electrically grounded in accordance with local codes or in the absence of local codes, with the national electrical code, ansi/nfpa 70 , or the canadian...

  • Page 5

    74d3001 5 dvbl7 series gas fireplace product features • this appliance has been certified for use with either natural or propane gas. See appropriate data plates. • this appliance is not for use with solid fuels. • the appliance is approved for bedroom or bedsitting room installations. • the applian...

  • Page 6

    74d3001 6 dvbl7 series gas fireplace pre-installation information r - rough opening width rough opening height rough opening depth a b c d e f g h i j k l m n o v q u t p 743000 bldv 7 dims o v s 1/2” or 5/8” (13 or 16 mm) gas line access 400 dvbl 500dvbl a 37 z\zn " (941 mm) 41 z\zn " (1043 mm) b 9...

  • Page 7

    74d3001 7 dvbl7 series gas fireplace before you start read this homeowner manual thoroughly and follow all instructions carefully. Inspect all contents for shipping damage and immediately inform your dealer if any damage is found. Do not install any unit with damaged, incomplete, or substitute parts...

  • Page 8

    74d3001 8 dvbl7 series gas fireplace pre-installation information fireplace location plan for the installation of your appliance. This includes determining where the unit is to be installed, the vent configuration to be used, framing and finishing details, and whether any optional accessories (i.E. ...

  • Page 9

    74d3001 9 dvbl7 series gas fireplace clearances clearances to combustibles mantel clearances note: the combustible area above the facing must not protrude more than 3/4" from the facing. If it does, it is considered a mantel and must meet the mantel requirements listed in this manual. Figure 4 - cle...

  • Page 10

    74d3001 10 dvbl7 series gas fireplace the fireplace must be secured to the floor and/or to framing studs as shown in figure 5. Use two () wood screws or masonry/ concrete screws to secure fireplace to the floor. Use four (4) screws to attach fireplace to framing. The side nailing flanges are 1/" or ...

  • Page 11

    74d3001 11 dvbl7 series gas fireplace installation precautions consult local building codes before beginning the installation. The installer must make sure to select the proper vent system for installation. Before installing vent kit, the installer must read this fireplace manual and vent kit instru...

  • Page 12

    74d3001 1 dvbl7 series gas fireplace venting installation information v v v v v v v x x x d e b b b c b m b a j k f l vent termination air supply inlet area where terminal is not permitted h i fixed closed operable operable fixed closed v b cfm145a dv termin location 5/01/01 rev. 12/05/01 sta inside...

  • Page 13

    74d3001 13 dvbl7 series gas fireplace fp2336 flex vent top venting installation information outside corner inside corner termination clearances termination clearances for buildings with combustible and noncombustible exteriors. G = combustible 6" (152 mm) noncombustible 2" (51 mm) f = combustible 6"...

  • Page 14

    74d3001 14 dvbl7 series gas fireplace venting installation information twist lock pipes when using twist lock pipe it is not necessary to use sealant on the joints. The only areas of the venting system that need to be sealed with high temperature silicone sealant are the sliding joints of any telesc...

  • Page 15

    74d3001 15 dvbl7 series gas fireplace vent installation w arn in g horizontal sections of this vent system require a minimum of 3" clearances to combustibles at the top of the flue and 1" clearance at the sides and bottom until the flue penetrates the outside wall. A minimum 1" clearance all around ...

  • Page 16

    74d3001 16 dvbl7 series gas fireplace vent installation vertical sidewall application minimum clearance between vent pipes and combus- tible materials is 3" (76 mm) on top, and 1" (25 mm) on the bottom and sides unless otherwise noted. Refer to page 15 when vent termination exits through foundations...

  • Page 17

    74d3001 17 dvbl7 series gas fireplace vent installation vo584-100 vent opening 2/99 djt vent opening for combustible walls 9 b\, ” (44 mm) min. Fireplace hearth framing detail opening for noncombustible wall 7 z\x ” (190 mm) fireplace hearth fp93 figure 16 - locate vent opening on wall. 9 b\, ” (44 ...

  • Page 18

    74d3001 18 dvbl7 series gas fireplace vent installation sealing vent pipe and firestop gaps with high tem- perature sealant will restrict cold air being drawn in around fireplace. Step 7 guide the vent terminations 4” and 7” collard into their respective vent pipes. Double check that the vent pipes ...

  • Page 19

    74d3001 19 dvbl7 series gas fireplace vent installation . Remove soil to a depth of approximately 16” (406 mm) below base of snorkel. Install drain pipe. Install window well (not supplied). Refill hole with 1” (305 mm) of coarse gravel leaving a clearance of approximately 4” (10 mm) below snorkel. F...

  • Page 20

    74d3001 0 dvbl7 series gas fireplace vent installation 1 2 3 4 1 2 3 4 12” min. Figure 24 - maximum elbow usage fp1179 vertical through-the-roof installation note: for all top vent vertical through-the-roof installa- tions, install the supplied cross-bar flue restrictor onto the top edge of the fire...

  • Page 21

    74d3001 1 dvbl7 series gas fireplace vent installation twl101a twist lock pipe 2/8/99 djt 3 #5 sheet metal screws per joint sealant storm collar twl101a figure 29 - roof flashing 2 ft. Min. 2 ft. Min. X 12 h* fp1971 min chimney clearance termination vent storm collar flashing lowest discharge openin...

  • Page 22

    74d3001 dvbl7 series gas fireplace fireplace installation check gas type use proper gas type for the fireplace you are installing. If you have conflicting gas type, do not install fireplace. See dealer where you purchased the fireplace for proper fireplace for your gas type or conversion kit. Instal...

  • Page 23

    74d3001 3 dvbl7 series gas fireplace fireplace installation a listed manual shutoff valve must be installed upstream of the appliance. Union tee and plugged 1/8" npt pres- sure tapping point should be installed upstream of the appliance. Figure 31 important: install main gas valve (equipment shutoff...

  • Page 24

    74d3001 4 dvbl7 series gas fireplace millivolt - checking gas pressure and electrical installation 1. Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is different from the fireplace, stop! Do not install the appliance. Contact your dealer ...

  • Page 25

    74d3001 5 dvbl7 series gas fireplace glass removal figure 33 - removing glass frame glass frame removal 1. Remove access panel by lifting up and out. . Release two clamps (500 model has three clamps) on bottom of fireplace. Figure 33 3. Tilt glass frame out and lift glass frame up until it clears th...

  • Page 26

    74d3001 6 dvbl7 series gas fireplace remote wall mounted switch a remote wall switch and up to fifteen (15) feet of 18 ga. Wire may be used with this appliance. Attach the wall switch in a junction box at the desired location on the wall. Figure 34 . Do not extend beyond the wall switch wire length ...

  • Page 27

    74d3001 7 dvbl7 series gas fireplace 3. Remove logs. 4. Remove grate from engine by lifting up. 5. Remove hearth brick and wall brick panels. 6. Disconnect the gas line to the valve. 7. Remove screws securing engine base to firebox floor and lift engine up to remove. 8. Two () magnetic strips have b...

  • Page 28

    74d3001 8 dvbl7 series gas fireplace kt505 install blower start position installed position kt505 figure 38 - blower installation position note: some older units are not equipped with mounting brackets. Velcro and magnets are used to mount blowers to sidewall and floor. Optional fan/blower system th...

  • Page 29

    74d3001 9 dvbl7 series gas fireplace operating instructions (milli-volt) a. This appliance is equipped with a pilot which must be lit with built-in piezo ignitor while following these instructions exactly. B. Before operating smell all around the appliance area for gas. Be sure to smell next to the ...

  • Page 30: Pilot

    74d3001 30 dvbl7 series gas fireplace operating instructions (milli-volt) pilot of f p il o t on fp1935 control knob pilot continued on next page approved leak testing method you may check for gas leaks with the following methods only: • soap and water solution • an approved leak testing spray • ele...

  • Page 31: Pilot

    74d3001 31 dvbl7 series gas fireplace operating instructions (milli-volt) pilot of f pilot o n of f pilo t on pilot fp1937 control knob on figure 44 - on position pilot of f p il o t on fp1935 control knob pilot figure 43 - on/off/rs switch off on rs lighting burner main burner switch the “on/off/rs...

  • Page 32

    74d3001 3 dvbl7 series gas fireplace signature command - check gas pressure and electrical installation figure 47 - signature command valve fp1909a signature command valve alternate view 8/08 pressure inlet pilot adjust- ment screw pressure outlet 1. Check gas type. The gas supply must be the same a...

  • Page 33

    74d3001 33 dvbl7 series gas fireplace signature command - electrical installation junction box wiring 1. This should be done before framing the fireplace. Wire the receptacle into an electrical circuit. Wire with minimum 60° c wire in accordance with prevailing codes. . Remove the external junction ...

  • Page 34

    74d3001 34 dvbl7 series gas fireplace to junction box in fireplace optional ac module { white black optional light white black { optional blower white black { optional aux. Green plug in connector connector pin to control board input 300 watt max. Each optional a/c module replaces 6v adapter when us...

  • Page 35

    74d3001 35 dvbl7 series gas fireplace to junction box in fireplace white black white black black white green connector pin to contro l box { { optional light optional aux blower (300w max) fp2684 blotsdvsc fan wiring blower (300w max) figure 50 - blotsdvsc blower wiring diagram fp103 control box opt...

  • Page 36

    74d3001 36 dvbl7 series gas fireplace black black white green black black white receptacle junction box 120vac speed control fp2685 blotsdv blower wiring optional fan blower systems blotsdv automatic thermostat blower figure 51 - blotsdv blower wiring diagram fp685 before installing the blower, wire...

  • Page 37

    74d3001 37 dvbl7 series gas fireplace operating instructions - signature command a. This appliance is equipped with an ignition device which automatically lights the pilot. Refer to the instructions. B. Before operating smell all around the appliance area for gas. Be sure to smell next to the floor ...

  • Page 38: Operating  Instructions

    74d3001 38 dvbl7 series gas fireplace operating instructions - signature command operating instructions 1. Stop! Read the safety information above. . This appliance is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand. 3. With five (5) min...

  • Page 39

    74d3001 39 dvbl7 series gas fireplace features command center • easy access function operation and system configuration • operation confirmation/fault diagnostic indications (led/ buzzer) • on/off/hi/med/low operation • optional wall mounting control board • electronic ignition • pilot lockout safet...

  • Page 40

    74d3001 40 dvbl7 series gas fireplace signature command system operation instructions system configuration/setup all system configuration/setup is done on the command center. Note: when using on/off wall switch, the switch must be in the on position to perform all configuration set ups at the comman...

  • Page 41

    74d3001 41 dvbl7 series gas fireplace signature command system operation instructions fault led indication conversion cover missing one red (1 time) spark fail two red (1 time) no sensor signal three red (1 time) pilot lockout - trial one green, every sec. (until manual reset) pilot lockout - flame ...

  • Page 42

    74d3001 4 dvbl7 series gas fireplace log & rock wool installation figure 54 - rock wool placement rock wool placement 1. Place rock wool on burner to provide glowing embers. For best results, pull the rock wool apart into pieces the size of a dime or smaller. . Distribute one layer of rock wool to c...

  • Page 43

    74d3001 43 dvbl7 series gas fireplace 5. Place the middle cross log (#6) by matching the rectangular notch on the bottom of this log with the rectangular protrusion of the rear log toward the left. The narrow pointed end will line up between the second left tong and the middle tong on the grate. 6. ...

  • Page 44

    74d3001 44 dvbl7 series gas fireplace burner, pilot and control compart- ment keep the control compartment, logs, and burner areas surrounding the logs clean by vacuuming or brushing at least twice a year. Make sure the burner porting, pilot air opening and burner air opening are free of obstruction...

  • Page 45

    74d3001 45 dvbl7 series gas fireplace cleaning and maintenance vent system the fireplace and venting system should be inspected before initial use and at least annually by a qualified field service person. Inspect the external vent cap on a regular basis to make sure that no debris is interfering wi...

  • Page 46

    74d3001 46 dvbl7 series gas fireplace troubleshooting standing pilot ignition millivolt system symptom possible cause action 1. Spark ignitor will not light pilot after repeated triggering of piezo. . Pilot will not stay lit after carefully follow- ing lighting instruc- tions. 3. Pilot burning, valv...

  • Page 47

    74d3001 47 dvbl7 series gas fireplace troubleshooting standing pilot ignition millivolt system 4. Frequent pilot outage problem. 5. The pilot and main burner extinguish while in operation 6. Glass soots 7. Flame burn blue and lifts off burner (ghosting) a. Pilot flame may be too high or too low, cau...

  • Page 48

    74d3001 48 dvbl7 series gas fireplace troubleshooting operation install batteries and/or plug in the ac board flip the master switch (rocker switch) to the on position press the on button on the command center fault no beep in about 8 seconds no beep or no sound from the valve indicating pilot solen...

  • Page 49

    74d3001 49 dvbl7 series gas fireplace replacement parts firebox components 4 3 7 6 2 5 743000 bldv 7 parts ref. Description qty. 400dvbl 500dvbl 1. Junction box assy (not shown) 1 6d18k 6d18k . Sheet metal base 1 74d0514 74d0515 3. Glass frame assy 1 74d0096k 74d011tk 4. Control cover 1 74d0038k 74d...

  • Page 50

    74d3001 50 dvbl7 series gas fireplace replacement parts standing pilot — millivolt control 1 2c 2i 2t 2 4 5 6 3 8 9 7 10 11,12,13,14 743000 bldv millivolt parts.

  • Page 51

    74d3001 51 dvbl7 series gas fireplace replacement parts standing pilot — millivolt control ref. Description qty. 400dvblnv7 400dvblpv7 500dvblnv7 500dvblpv7 1. Gas valve assy 1 37d0117 37d0118 37d0117 37d0118 . Pilot assy 1 37d0018 37d0019 37d0018 37d0019 c. Replacement thermocouple 1 37d1067 37d106...

  • Page 52

    74d3001 5 dvbl7 series gas fireplace replacement parts signature command system 743000 bldv sc parts 1 2 3 4 20 5 6 7 8 9 13, 14, 15, 16, 17 12.

  • Page 53

    74d3001 53 dvbl7 series gas fireplace replacement parts item description qty. 400dvblns7 400dvblps7 500dvblns7 500dvblps7 1 gas valve assembly 1 80d0001 80d000 80d0001 80d000 pilot assembly 1 80d0006 80d0007 80d0006 80d0007 3 control box 1 80d0018 80d0019 80d0018 80d0019 4 command center 1 80d0005 8...

  • Page 54

    74d3001 54 dvbl7 series gas fireplace logs replacement parts 1 6 5 2 3 4 743000 bldv log parts ref. Description qty. 400dvbl 500dvbl 1. Rear log #1 1 74d0053 74d0053 . Top right log # 1 74d0060 74d0060 3. Front upper log #3 1 74d0061 74d0061 4. Right front log #4 1 74d006 74d006 5. Left front log #5...

  • Page 55

    74d3001 55 dvbl7 series gas fireplace venting components description model number vertical vent termination kits vertical vent termination w/ storm collar 7tdvskv (flashing not included) vertical vent termination w/ storm collar - 8 pack 7tdvskv/8 (flashing not included) vertical vent termination w/...

  • Page 56

    74d3001 56 dvbl7 series gas fireplace venting components description model number horizontal vent termination kits rear vent hot touch termination kit w/ 10" to 16" 7tbrhtk adjustable termination pipe, firestop, and hot touch termination w/ siding shield up and out side wall termination kit w/ 10" t...

  • Page 57

    74d3001 57 dvbl7 series gas fireplace.

  • Page 58

    74d3001 58 dvbl7 series gas fireplace requirements for the commonwealth of massachusetts this product must be installed by a licensed plumber or gas fitter when installed within the commonwealth of massachusetts. Note regarding vented products flex line installation must not exceed 36 inches and mus...

  • Page 59

    74d3001 59 dvbl7 series gas fireplace limited lifetime warranty policy lifetime warranty the following components are warranted for life to the original owner, subject to proof of purchase: firebox, combustion chamber, heat exchanger, grate and stainless steel burners. Five year warranty the followi...

  • Page 60

    Mhsc 149 cleveland drive • paris, kentucky 40361 www.Mhsc.Com based on csa p.4.1-09 efficiency ratings model energuide ratings fireplace efficiency (%) 400dvblnv7 63.8 400dvblpv7 60. 400dvblnsc7 68.1 400dvblpsc7 6.8 500dvblnv7 61.1 500dvblpv7 64.9 500dvblnsc7 64.1 500dvblpsc7 67.9.