Majestic 300DVB User Manual

Manual is about: DVB Series Direct Vent Gas Fireplace

Summary of 300DVB

  • Page 1

    Dvb direct vent gas fireplace models: 300dvb, 400dvb, 500dvb, 600dvb 540701 dvb cover warning if the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. – do not store or use gasoline or other flammable v...

  • Page 2

    Dvb series direct vent gas fireplace 54d0701 contents important safety information .....................................3 code approval .............................................................4 product features .........................................................5 high elevations ............

  • Page 3

    Dvb series direct vent gas fireplace 54d0701 3 important safety information installer please leave these instructions with the appliance. Owner please retain these instructions for future reference. • read this owner’s manual carefully and completely before trying to assemble, operate, or service th...

  • Page 4

    Dvb series direct vent gas fireplace 4 54d0701 important safety information 1. Do not use this fireplace to cook food or burn paper or other objects. 13. Never place anything on top of fireplace. 14. Do not use any solid fuels (wood, coal, paper, card- board, etc.) in this fireplace. Use only the ga...

  • Page 5

    Dvb series direct vent gas fireplace 54d0701 5 product features product specifications • this appliance has been certified for use with either natural or propane gas. Refer to appropriate data plates. • this appliance is not for use with solid fuels. • the appliance is approved for bedroom or bedsit...

  • Page 6

    Dvb series direct vent gas fireplace 6 54d0701 fireplace & framing dimensions 5/8” 1/2” 5/8” 1/2” l c a b m 3 56o ” 8 56m ” j 5/8" 1/2” 5/8" 1/2” 540701 dvb/bdv dims e d h 1/2” or 5/8” min. Rough opening height f g n i 5/8” 1/2” 5/8” 1/2” o - min. Rough opening width min. Rough opening depth p q r s...

  • Page 7

    Dvb series direct vent gas fireplace 54d0701 7 pre-installation information before you start read this homeowner manual thoroughly and follow all instructions carefully. Inspect all contents for shipping damage and immediately inform your dealer if any damage is found. Do not install any unit with d...

  • Page 8

    Dvb series direct vent gas fireplace 8 54d0701 fireplace location plan for the installation of your appliance. This includes determining where the unit is to be installed, the vent configuration to be used, framing and finishing details, and whether any optional accessories (i.E. Blower, wall switch...

  • Page 9

    Dvb series direct vent gas fireplace 54d0701 9 clearances clearances to combustibles w arning follow these instructions carefully to ensure safe installation. Failure to follow instructions exactly can create a fire hazard. The appliance cannot be installed on a carpet, tile or other combustible mat...

  • Page 10

    Dvb series direct vent gas fireplace 10 54d0701 secure fireplace to floor or framing the fireplace must be secured to the floor and/or to framing studs as shown in figure 6 . Use two () wood screws or masonry/ concrete screws to secure fireplace to the floor. Use four (4) screws to attach fireplace ...

  • Page 11

    Dvb series direct vent gas fireplace 54d0701 11 venting installation optional top vent application the appliance is shipped as a rear vent unit. If the installa- tion layout requires the unit to be a top vent configuration the appliance can be converted by following the steps below. When removing an...

  • Page 12

    Dvb series direct vent gas fireplace 1 54d0701 venting installation information installation precautions consult local building codes before beginning the installation. The installer must make sure to select the proper vent system for instal- lation. Before installing vent kit, the installer must re...

  • Page 13

    Dvb series direct vent gas fireplace 54d0701 13 vent installation w arning never run the vent pipe down. This may cause excessive temperatures which could cause a fire. Installation planning there are two basic types of direct-vent installation: • horizontal termination • vertical termination it is ...

  • Page 14

    Dvb series direct vent gas fireplace 14 54d0701 venting installation v v v v v v v x x x d e b b b c b m b a j k f l vent termination air supply inlet area where terminal is not permitted h i fixed closed operable operable fixed closed v b cfm145a dv termin location 5/01/01 rev. 12/05/01 sta inside ...

  • Page 15

    Dvb series direct vent gas fireplace 54d0701 15 venting installation v g g=6" (152mm) f f=6" (152mm) v v g g = combustible 24"(610mm) noncombustible 18"(457mm) combustible & noncombustible h = 24" (610mm) j = 20" (508mm) v h j c = maximum depth of 48" (1219mm) for alcove location d = minimum width f...

  • Page 16

    Dvb series direct vent gas fireplace 16 54d0701 venting installation rear (through the wall) applica- tions when installed as a rear vent unit this appliance may be vented directly to a termination located on the rear wall behind the appliance • the maximum horizontal distance between the rear of th...

  • Page 17

    Dvb series direct vent gas fireplace 54d0701 17 venting installation hot fp1955 horizontal vent cap vent cap wood screw apply mastic to all four sides fp1955 figure 17 - install horizontal termination w arning do not recess vent termination into any wall. This will cause a fire hazard. Hot fp1956 vi...

  • Page 18

    Dvb series direct vent gas fireplace 18 54d0701 venting installation note: horizontal sections of this vent system require a minimum of 3" clearances to combustibles at the top of the flue and 1" clearance at the sides and bottom until the flue penetrates the outside wall. A minimum 1" clearance all...

  • Page 19

    Dvb series direct vent gas fireplace 54d0701 19 venting installation a: 10’ b: 7’ 7’6” fp1959 max run w/elbows fp1959 figure 24 - maximum vent run with elbows 90° elbows = 3’ a + b = 17’ maximum 1 2 3 4 1 2 3 4 fp1180 1 + + 3 + 4 = 70° example: elbow 1 = 90° elbow = 45° elbow 3 = 45° elbow 4 = 90° t...

  • Page 20

    Dvb series direct vent gas fireplace 0 54d0701 venting installation fp1966 snorkel foundation recess snorkel wall screws sheet metal screws watertight seal around pipe fp1966 figure 27 - snorkel installation, recessed foundation w arning • do not back fill around snorkel. • a clearance of at least 4...

  • Page 21

    Dvb series direct vent gas fireplace 54d0701 1 venting installation 1 2 3 4 1 2 3 4 fp1179 max bends fp1179 figure 29 - maximum elbow usage installation for vertical termina- tion 1. Determine the route your vertical venting will take. If ceiling joist, roof rafters or other framing will obstruct th...

  • Page 22

    Dvb series direct vent gas fireplace 54d0701 venting installation . Assemble the desired lengths of pipe and elbows nec- essary to reach from the burner system flue up through the firestop. Be sure pipe and elbow connections are fully twist-locked. Page 18, figure 15. 3. Cut a hole in the roof using...

  • Page 23

    Dvb series direct vent gas fireplace 54d0701 3 flex venting installation 1. Flexible ul1777 listed venting may be used in any venting application where rigid direct vent compo- nents can be used. All restrictions, clearances and allowances that pertain to the rigid piping apply to the flexible venti...

  • Page 24

    Dvb series direct vent gas fireplace 4 54d0701 flex venting installation 5. Flexible vent spacers are to be installed at intervals prescribed by the flexible vent manufacturer; and in such a way as to maintain concentric inner and outer vent spacing. D. Attaching flexible venting to vertical termina...

  • Page 25

    Dvb series direct vent gas fireplace 54d0701 5 fireplace installation check gas type use proper gas type for the fireplace you are installing. If you have conflicting gas type, do not install fireplace. See dealer where you purchased the fireplace for proper fireplace for your gas type or conversion...

  • Page 26

    Dvb series direct vent gas fireplace 6 54d0701 fireplace installation w arning only persons licensed to work with gas piping may make the necessary gas connections to this appliance. C a ut io n a manual shutoff valve must be installed upstream of the appliance. Union tee and plugged 1/8” npt pressu...

  • Page 27

    Dvb series direct vent gas fireplace 54d0701 7 millivolt & electronic check gas pressure and electrical installation 1. Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is different from the fireplace, stop! Do not install the appliance. Co...

  • Page 28

    Dvb series direct vent gas fireplace 8 54d0701 electrical installation remote wall mounted switch a remote wall switch and up to fifteen (15) feet of 18 ga. Wire may be used with this appliance. Attach the wall switch in a junction box at the desired location on the wall. Figure 42 . Do not extend b...

  • Page 29

    Dvb series direct vent gas fireplace 54d0701 9 electrical installation electronic pilot ignition wiring w arning do not connect 110-120v ac to the remote wall switch. The appliance will malfunction. Hi lo electronic valve red #2 gray #1 blue yellow yellow red #2 white #3 15’ wall switch wire b lack ...

  • Page 30

    Dvb series direct vent gas fireplace 30 54d0701 optional fan / blower system optional fan/blower systems (blot) the junction box for the fan/blower systems has been factory installed. This system requires that 110-10 vac to be wired to the factory installed junction box before the fireplace is perma...

  • Page 31

    Dvb series direct vent gas fireplace 54d0701 31 operating instructions (millivolt) a. This appliance is equipped with a pilot which must be lit with built-in piezo ignitor while following these instructions exactly. B. Before operating smell all around the appliance area for gas. Be sure to smell ne...

  • Page 32: Pilot

    Dvb series direct vent gas fireplace 3 54d0701 operating instructions (millivolt) pilot of f p il o t on fp1935 control knob pilot continued on next page approved leak testing method you may check for gas leaks with the following methods only: • soap and water solution • an approved leak testing spr...

  • Page 33: Pilot

    Dvb series direct vent gas fireplace 54d0701 33 operating instructions (millivolt) pilot of f pilot o n of f pilo t on pilot fp1937 control knob on figure 47 - on position pilot of f p il o t on fp1935 control knob pilot figure 46 - on/off/rs switch off on rs lighting burner main burner switch the “...

  • Page 34: To Turn Off Gas

    Dvb series direct vent gas fireplace 34 54d0701 1. Stop! Read the safety information above. . Make sure all power to unit is turned off. 3. Set thermostat to lowest setting. 4. This appliance is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by...

  • Page 35

    Dvb series direct vent gas fireplace 54d0701 35 signature command - check gas pressure and electrical installation 1. Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is different from the fireplace, stop! Do not install the appliance. Cont...

  • Page 36

    Dvb series direct vent gas fireplace 36 54d0701 signature command - electrical installation c a ut io n electrical connections should only be performed by a qualified, licensed electrician. Main power supply must be turned off before connecting fans to the main electrical power supply or performing ...

  • Page 37

    Dvb series direct vent gas fireplace 54d0701 37 optional fan blower system optional fan/blower system (blotsc) installation instructions wiring 1. Before installing the blower, wire the receptacle into an electrical circuit. This should be done before framing the fireplace. Wire with minimum 60° c w...

  • Page 38

    Dvb series direct vent gas fireplace 38 54d0701 to junction box in fireplace white black white black black white green connector pin to contro l box { { optional light optional aux blower (300 w max) fp2103 ac fan wiring figure 57 - blower wiring diagram fp103 control box optional ac box optional fa...

  • Page 39

    Dvb series direct vent gas fireplace 54d0701 39 operating instructions - signature command a. This appliance is equipped with an ignition device which automatically lights the pilot. Refer to the instructions for match lighting. B. Before operating smell all around the appliance area for gas. Be sur...

  • Page 40: Operating  Instructions

    Dvb series direct vent gas fireplace 40 54d0701 operating instructions - signature command operating instructions 1. Stop! Read the safety information above. . This appliance is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand. 3. With fi...

  • Page 41

    Dvb series direct vent gas fireplace 54d0701 41 signature command system operation instructions features command center • easy access function operation and system configu- ration • operation confirmation/fault diagnostic indications (led/buzzer) • on/off/hi/low operation control board • electronic ...

  • Page 42

    Dvb series direct vent gas fireplace 4 54d0701 signature command system operation instructions system configuration/setup system configuration/setup is done on the command center. Intermittent/standing pilot setup (default intermittent) 1. Holding the on button on the command center while turning on...

  • Page 43

    Dvb series direct vent gas fireplace 54d0701 43 signature command system operation instructions functions/operation turning on the fireplace 1. Turn on the master switch and wait for a beep. . Press the on button on the command center. Pilot will light and burner will come on high setting. Pilot saf...

  • Page 44

    Dvb series direct vent gas fireplace 44 54d0701 glass removal glass frame removal 1. Release two clamps on bottom of fireplace. Figure 59 . Tilt glass frame out and lift glass frame up until it clears three tabs on top of fireplace. 3. Set glass frame aside. Fp2104 bdv remove glass fp104 figure 59 -...

  • Page 45

    Dvb series direct vent gas fireplace 54d0701 45 final installation rock wool placement 1. Place rock wool on burner to provide glowing embers. For best results, pull the rock wool apart into pieces the size of a dime or smaller. . Distribute one layer of rock wool to cover the burner. Figure 60 3. P...

  • Page 46

    Dvb series direct vent gas fireplace 46 54d0701 cleaning and maintenance w arning turn off gas before servicing fireplace. It is recommended that a qualified service technician perform these check-ups at the beginning of each heating season. Burner, pilot and control compartment keep the control com...

  • Page 47

    Dvb series direct vent gas fireplace 54d0701 47 cleaning and maintenance vent system the fireplace and venting system should be inspected before initial use and at least annually by a qualified field service person. Inspect the external vent cap on a regular basis to make sure that no debris is inte...

  • Page 48

    Dvb series direct vent gas fireplace 48 54d0701 troubleshooting standing pilot ignition symptom possible cause action 1. Spark ignitor will not light pilot after repeated triggering of piezo. . Pilot will not stay lit after carefully follow- ing lighting instruc- tions. 3. Pilot burning, valve knob ...

  • Page 49

    Dvb series direct vent gas fireplace 54d0701 49 troubleshooting standing pilot ignition symptom possible cause action 4. Frequent pilot outage problem. 5. The pilot and main burner extinguish while in operation 6. Glass soots 7. Flame burn blue and lifts off burner (ghosting) a. Pilot flame may be t...

  • Page 50

    Dvb series direct vent gas fireplace 50 54d0701 troubleshooting operation install batteries and/or plug in the ac board flip the master switch (rocker switch) to the on position press the on button on the command center fault no beep in about 8 seconds no beep or no sound from the valve indicating p...

  • Page 51

    Dvb series direct vent gas fireplace 54d0701 51 replacement parts 1 2 3 5 6 7 8 10 4 9 540701 dvb parts firebox components.

  • Page 52

    Dvb series direct vent gas fireplace 5 54d0701 replacement parts firebox components item description qty. 300dvb 400dvb 500dvb 600dvb standard features 1. Junction box 1 6d18k 6d18k 6d18k 6d18k . Black louver 6 54d046 6d0695 6d0697 6d0699 3. Glass frame assembly 1 54d094 54d0195 54d0340 54d0443 fact...

  • Page 53

    Dvb series direct vent gas fireplace 54d0701 53 replacement parts standing pilot - millivolt control 1 2c 2i 2t 2 4 5 6 3 8 9 7 10 11,12,13,14 540701 dvb millivolt parts.

  • Page 54

    Dvb series direct vent gas fireplace 54 54d0701 replacement parts standing pilot - millivolt control item description qty. 300dvbnv 300dvbpv 400dvbdnv 400dvbpv 500dvbnv 500dvbpv 600dvbnv 600dvbpv 1. Gas valve assy. 1 37d0117 37d0118 37d0117 37d0118 37d0117 37d0118 37d0117 37d0118 . Pilot assembly 1 ...

  • Page 55

    Dvb series direct vent gas fireplace 54d0701 55 replacement parts electronic igntion 1 2 4 5 6 3 8 9 7 10 11 lo hi 24v #6 24v gnd #5 pv #3 mv/pv #2 mv #1 gnd (burner) #4 sense #8 s p ark #9 540701 dvb elect parts.

  • Page 56

    Dvb series direct vent gas fireplace 56 54d0701 replacement parts electronic igntion item description qty. 300dvbne 300dvbpe 400dvbne 400dvbpe 500dvbne 500dvbpe 600dvbne 600dvbpe 1. Gas valve assy. 1 37d0016 37d0017 37d0016 37d0017 37d0016 37d0017 37d0016 37d0017 . Pilot assembly 1 37d000 37d001 37d...

  • Page 57

    Dvb series direct vent gas fireplace 54d0701 57 replacement parts 1 2 3 4 17 5 6 7 8 9 13, 14, 15 540701 sc parts signature command system.

  • Page 58

    Dvb series direct vent gas fireplace 58 54d0701 replacement parts signature command system item description qty. 300dvbns 300dvbps 400dvbns 400dvbps 500dvbns 500dvbps 600dvbns 600dvbps 1. Gas valve assy. 1 80d0001 80d000 80d0001 80d000 80d0001 80d000 80d0001 80d000 . Pilot assembly 1 80d0006 80d0007...

  • Page 59

    Dvb series direct vent gas fireplace 54d0701 59 replacement parts vent components hot 1 2 3 4 5 6 9 7 8 11 10 540701 dvb vent components.

  • Page 60

    Dvb series direct vent gas fireplace 60 54d0701 replacement parts vent components current old simpson simpson duravent duravent qty./ or mhsc or mhsc selkirk item box description part no. Part no. Part no. 1 1 side wall flexible pipe termination kit bhsftka bhsftk -- includes termination cap with bu...

  • Page 61

    Dvb series direct vent gas fireplace 54d0701 61 replacement parts logs 1 2 3 4 540701 dvb log parts ref. Description qty. 300dvb 400dvb 500dvb 600dvb 1. Rear log #1 1 54d01 54d0117 54d0331 54d0331 . Bottom left log # 1 54d013 54d0118 54d0358 54d0358 3. Bottom right log #3 1 54d014 54d0119 54d0359 54...

  • Page 62

    Dvb series direct vent gas fireplace 6 54d0701 note regarding vented products this product must be installed by a licensed plumber or gas fitter when installed within the commonwealth of massachusetts. Any residence with a direct vent product must have a co detector installed in the residence. Insta...

  • Page 63

    Dvb series direct vent gas fireplace 54d0701 63 limited lifetime warranty policy lifetime warranty the following components are warranted for life to the original owner, subject to proof of purchase: firebox, combustion chamber, heat exchanger, grate and stainless steel burners. Five year warranty t...

  • Page 64

    Mhsc 149 cleveland drive • paris, kentucky 40361 www.Mhsc.Com efficiency ratings model energuide ratings fireplace efficiency (%) 300dvbnv 57.9 300dvbpv 53.8 300dvbne 61.8 300dvbpe 55.7 400dvbnv 58.4 400dvbpv 58.5 400dvbne 61.1 400dvbpe 60.7 500dvbnv 58.7 500dvbpv 58.8 500dvbne 61.3 500dvbpe 60.8 60...