  • Page 1

    If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. – do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. – what to do if you smell gas • do ...

  • Page 2

    33isdg vent free gas fireplace system 2 23d8036 contents important safety information ..................................... 3 codes ...................................................................... 4 product features ......................................................... 5 operation ...........

  • Page 3

    33isdg vent free gas fireplace system 23d8036 3 13. Avoid any drafts that alter burner flame patterns. Do not allow fans to blow directly into fireplace. Do not place a blower inside burn area of firebox. Ceiling fans may create drafts that alter burner flame patterns. Sooting and improper burning w...

  • Page 4

    33isdg vent free gas fireplace system 4 23d8036 important safety information the initial break-in operation should last two to three hours with the burner at the highest setting. Provide maximum ventilation by opening windows or doors to allow odors to dissipate. Any odors remaining after this initi...

  • Page 5

    33isdg vent free gas fireplace system 23d8036 5 fp2784 33isdg product features your vent-free fireplace must be mounted to the floor or the fireplace hearth. Operation this unvented gas heater requires no outside venting and burns cleanly with high heating efficiency. Product features piezo ignitor ...

  • Page 6

    33isdg vent free gas fireplace system 6 23d8036 33 56o ” rough opening width rough opening depth 1/2” or 5/8” rough opening height 238020 dis33g dims 16” 37 56m ” 31 (6 ” 64 56m ” 37 56m ” 27 56o ” 33 56o ” rough opening width rough opening depth 1/2” or 5/8” rough opening height 16” 37 56m ” 31 (6 ...

  • Page 7

    33isdg vent free gas fireplace system 23d8036 7 preinstallation information getting started make sure you have received all parts check your packing list to verify that all listed parts have been received. You should have the following: • installation/operating instructions • black louvers (5) • 33"...

  • Page 8

    33isdg vent free gas fireplace system 8 23d8036 w arning clearance and height requirements the dimensions shown in figures 4 and 5 and defined in the fireplace manufacturer's instructions are minimum clearances to maintain when installing this heater. Left and right clearances are determined when fa...

  • Page 9

    33isdg vent free gas fireplace system 23d8036 9 clearances heat resistant material (minimum requirements) with no wooden mantel or other combustible projection heat resistant material (minimum requirements) with wooden mantel or other combustible projection: to install the heater with a wooden mante...

  • Page 10

    33isdg vent free gas fireplace system 10 23d8036 fp2786 remove screen clearances and installation the gas log heater must be installed at least 5" above any combustible flooring material, such as carpeting or tile, which is closer than 14" to the base of the fireplace. Figure 8 5" 1” fp2775 min clea...

  • Page 11

    33isdg vent free gas fireplace system 23d8036 11 fp2788 isdg secure firebox fp2787 isdg remove grate secure heater to floor note: clearance requirements as detailed in “clearances and height requirements” section of this manual must be met before securing heater in place. To prevent movement, the he...

  • Page 12

    33isdg vent free gas fireplace system 12 23d8036 fp2789 isdg gas line access notice: a qualified gas appliance installer must connect the heater to the gas supply. Consult all local codes. W arning use new black iron or steel pipe. Internally tinned copper or copper tubing can be used per national f...

  • Page 13

    33isdg vent free gas fireplace system 23d8036 13 check gas pressure millivolt control figure 15 the valve regulator controls the burner pressure which should be checked at the pressure test point. Turn captured screw counter clockwise two or three turns and then place tubing to pressure gauge over t...

  • Page 14

    33isdg vent free gas fireplace system 14 23d8036 fp2112 wiring diagram 12/08 figure 16 - wiring diagram optional wall switch or remote receiver switch on/off switch on/off switch wall switch ods pilot valve th = 3 tp = 1 tp/th = 2 ods pilot spade terminal fp2112 w arning label all wires prior to dis...

  • Page 15

    33isdg vent free gas fireplace system 23d8036 15 connect remote receiver figure 17 these instructions supersede the section entitled “hearth mount” in the milli-volt hand-held remote instructions supplied with the remote. 1. Remove cover on control panel to show opening for remote receiver . 2. Conn...

  • Page 16

    33isdg vent free gas fireplace system 16 23d8036 electrical wiring - fan w arning w arning this fireplace has a three-prong, grounded electrical plug. This plug helps protect you against electrical shock. Only connect plug to a properly grounded, three-prong receptacle. Do not cut or remove the grou...

  • Page 17

    33isdg vent free gas fireplace system 23d8036 17 lg932 isd rear log installing blazing oak logs on burner log placement before you begin — this unit is supplied with six (6) ceramic fiber logs. Do not handle these logs with your bare hands. Always wear gloves to prevent skin irritation from ceramic ...

  • Page 18

    33isdg vent free gas fireplace system 18 23d8036 lg934 isd left top log lg933 isd left base right top logs log placement left base log #3 left base log #3 right top log #4 right top log #4 pins lg934 3. Place left base log (#3) on two pins on left side of grate. Figure 21 4. Place right top log (#4)...

  • Page 19

    33isdg vent free gas fireplace system 23d8036 19 lg935 isd right front log lg929 dis33g rockwool log placement right top log #6 right top log #6 pins lg935 figure 23 6. Place right front log (#6) on two pins on the right front of grate. Figure 23 w arning • use only tpb rock wool provided with log s...

  • Page 20

    33isdg vent free gas fireplace system 20 23d8036 lg936 isd log flames fp2273 pilot bad flame fp2272 pilot correct flame flame appearance flames from the pilot, front and rear burner should be visually checked as soon as the heater is installed. In addition, periodically check the flames visually dur...

  • Page 21

    33isdg vent free gas fireplace system 23d8036 21 operating instructions avoid any drafts that alter burner flame patterns. Do not allow fans to blow directly into the fireplace. Do not place a blower inside the burn area of the firebox. Ceiling fans may create drafts that alter flame patterns. Sooti...

  • Page 22

    33isdg vent free gas fireplace system 22 23d8036 w arning location of piezo ignitor, control knobs and switch on millivolt unit, hi/lo remote control and manual unit a. This appliance is equipped with a piezo ignition device which automatically lights the pilot. If the piezo is not working properly ...

  • Page 23: Millivolt/thermostat Control

    33isdg vent free gas fireplace system 23d8036 23 fp2784 control panel 1. Stop! Read the safety information label. 2. Make sure the manual shutoff valve is fully open. 3. This gas log set is equipped with an ignition device (piezo) which automatically lights the pilot. If piezo ignitor does not light...

  • Page 24

    33isdg vent free gas fireplace system 24 23d8036 locate the blower control by opening control access door. The variable controlled thermostat blower is located to the right of heater controls. . In the off position, the blower will not operate; however, the heater can be operated without the blower ...

  • Page 25

    33isdg vent free gas fireplace system 23d8036 25 annual inspection and cleaning by your dealer or qualified service technician is recom- mended to prevent malfunction and/or sooting. Remove logs, handling carefully by holding gently at each end. Gloves are recommended to prevent skin irritation from...

  • Page 26

    33isdg vent free gas fireplace system 26 23d8036 observed problem when ignitor button is pressed, there is no spark at ods/pilot. Appliance produces unwanted odors. Appliance shuts off during use. Gas odor even when control knob is in off position. When ignitor button is pressed, there is spark at o...

  • Page 27

    33isdg vent free gas fireplace system 23d8036 27 observed problem ods/pilot lights, but flame goes out when control knob is released. Burner does not light after ods/ pilot is lit. Burner backfires during combus- tion. Slight smoke or odor during initial operation. Logs appear to smoke after initial...

  • Page 28

    33isdg vent free gas fireplace system 28 23d8036 replacement parts w arning failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. 1 2 3 4 8 8 8 8 8 8 13 7 5 6 14 12 2380...

  • Page 29

    33isdg vent free gas fireplace system 23d8036 29 replacement parts firebox parts ref. Description qty. 33isdg 1. Screen assembly 1 23d8028 2. Canopy assembly 1 23d8027 3. Top black louver 2 23d0200k 4. Bottom black hang-on louver assy. 1 23d8016 5. Left firebrick 1 53d0753 6. Right firebrick 1 53d07...

  • Page 30

    33isdg vent free gas fireplace system 30 23d8036 replacement parts w arning failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. 7 1 2 3 4 5 6 8a 8b 238020 dis33g burne...

  • Page 31

    33isdg vent free gas fireplace system 23d8036 31 replacement parts are available through your retailer. Replacement parts burner assembly ref. Description qty. Dis33n dis33p 1. Piezo ignitor 1 14d0503 14d0503 2. Piezo wie 1 00k0632 00k0632 3. Burner 1 70d0104 70d0104 4. Control valve 1 14d0467 14d04...

  • Page 32

    33isdg vent free gas fireplace system 32 23d8036 replacement parts are available through your retailer. Replacement parts w arning failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or p...

  • Page 33

    33isdg vent free gas fireplace system 23d8036 33.

  • Page 34

    33isdg vent free gas fireplace system 34 23d8036.

  • Page 35

    33isdg vent free gas fireplace system 23d8036 35 limited lifetime warranty policy lifetime warranty the following components are warranted for life to the original owner, subject to proof of purchase: firebox, combustion chamber, heat exchanger, grate and stainless steel burners. Five year warranty ...

  • Page 36

    Mhsc 149 cleveland drive • paris, kentucky 40361 www.Mhsc.Com.