    Model: 500dvkst dvkst series direct vent gas fireplace if the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. – do not store or use gasoline or other flammable vapors and liquids in the vicinity of th...

  • Page 2

    2 73d4126 dvkst series gas fireplace contents important safety information ...................................... 3 code approval .............................................................. 4 product features .......................................................... 5 high elevations ..............

  • Page 3

    73d4126 3 dvkst series gas fireplace 4. Never install the fireplace • in a recreational vehicle • where curtains, furniture, clothing, or other flam- mable objects are less than 42" from the front, top, or sides of the fireplace • in high traffic areas • in windy or drafty areas 5. This fireplace re...

  • Page 4

    4 73d4126 dvkst series gas fireplace important safety information & code approval 15. This appliance, when installed, must be electrically grounded in accordance with local codes or in the absence of local codes, with the national electrical code, ansi/nfpa 70, or the canadian electrical code, csa c...

  • Page 5

    73d4126 5 dvkst series gas fireplace product features product specifications • this appliance has been certified for use with either natural or propane gas. See appropriate data plates. • this appliance is not for use with solid fuels. • the appliance is approved for bedroom or bedsitting room insta...

  • Page 6

    Fireplace & framing dimensions 6 73d4126 dvkst series gas fireplace rough opening height 1/2” or 5/8” recessed nailing flange 50” (1270 mm) rough opening width rough opening depth 36” (914 mm) 396 ” (1007 mm) 446m” (1137 mm) 456m” (108 mm) 4456o” (1130 mm) 386 ” (981 mm) 23” (584 mm) 24” (610 mm) 49...

  • Page 7

    73d4126 7 dvkst series gas fireplace pre-installation information before you start read this homeowner manual thoroughly and follow all instructions carefully. Inspect all contents for shipping damage and immediately inform your dealer if any damage is found. Do not install any unit with damaged, in...

  • Page 8

    8 73d4126 dvkst series gas fireplace pre-installation information fireplace location plan for the installation of your appliance. This includes determining where the unit is to be installed, the vent configuration to be used, framing and finishing details, and whether any optional accessories (i.E. ...

  • Page 9

    73d4126 9 dvkst series gas fireplace clearances clearances to combustibles follow these instructions carefully to ensure safe installation. Failure to follow instructions exactly can create a fire hazard. The appliance cannot be installed on a carpet, tile or other combustible material other than wo...

  • Page 10

    10 73d4126 dvkst series gas fireplace secure fireplace to floor or framing the fireplace must be secured to the floor and/or to framing studs as shown in figure 6 . Use four (4) wood screws or masonry/ concrete screws to secure fireplace to the floor. Use four (4) screws to attach fireplace to frami...

  • Page 11

    73d4126 11 dvkst series gas fireplace venting installation installation precautions consult local building codes before beginning the installation. The installer must make sure to select the proper vent system for installation. Before installing vent kit, the installer must read this fireplace manua...

  • Page 12

    12 73d4126 dvkst series gas fireplace venting installation installation planning there are two basic types of direct-vent installation: • horizontal termination • vertical termination it is important to select the proper length of vent pipe for the type of termination you choose. It is also importan...

  • Page 13

    73d4126 13 dvkst series gas fireplace venting installation general venting information - termination location a = clearance above grade, veranda, porch, 12” (30 cm) 12” (30 cm) deck, or balcony b = clearance to window or door that may be 6” (15 cm) for appliances 6” (15 cm) for appliances opened for...

  • Page 14

    14 73d4126 dvkst series gas fireplace v g g=6" (152mm) f f=6" (152mm) v v g g = combustible 24"(610mm) noncombustible 18"(457mm) combustible & noncombustible h = 24" (610mm) j = 20" (508mm) v h j c = maximum depth of 48" (1219mm) for alcove location d = minimum width for back wall of alcove location...

  • Page 15

    73d4126 15 dvkst series gas fireplace venting installation vertical/horizontal termination configurations since it is very important that the venting system main- tain its balance between the combustion air intake and the flue gas exhaust, certain limitations as to vent con- figurations apply and mu...

  • Page 16

    16 73d4126 dvkst series gas fireplace a b 10’ 90° fp2546 horizontal run reduction venting installation example: elbow 1 = 90° elbow 2 = 45° elbow 3 = 45° elbow 4 = 90° total angular variation = 270° figure 14 - maximum elbow usage 1 2 3 4 1 2 3 4 fp1180 max bends 24" minimum fp1180 below grade insta...

  • Page 17

    73d4126 17 dvkst series gas fireplace venting installation if the foun- d a t i o n i s r e c e s s e d , use recess brackets (not supplied) for s e c u r i n g lower portion of the snor- kel. Fasten brackets to w a l l f i r s t , then secure to snorkel with self drill- ing #8 x 1/2 sheet metal s c...

  • Page 18

    18 73d4126 dvkst series gas fireplace installation for vertical termina- tion 1. Determine the route your vertical venting will take. If ceiling joist, roof rafters or other framing will obstruct the venting system, consider an offset. Refer to figure 19 to avoid cutting load bearing members. For op...

  • Page 19

    73d4126 19 dvkst series gas fireplace venting installation 2. Assemble the desired lengths of pipe and elbows nec- essary to reach from the burner system flue up through the firestop. Be sure pipe and elbow connections are fully twist-locked. 3. Cut a hole in the roof using the locating hole as a ce...

  • Page 20

    20 73d4126 dvkst series gas fireplace fireplace installation check gas type use proper gas type for the fireplace you are installing. If you have conflicting gas type, do not install fireplace. See dealer where you purchased the fireplace for proper fireplace according to your gas type. Installing g...

  • Page 21

    73d4126 21 dvkst series gas fireplace fireplace installation note : the gas line connection may be made using 1/2" rigid tubing or an approved flex connector. Since some municipalities have additional local codes it is always best to consult your local authorities and the current edition of the nati...

  • Page 22

    22 73d4126 dvkst series gas fireplace fp1909a signature command valve alternate view 8/08 1. Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is different from the fireplace, stop! Do not install the appliance. Contact your dealer immediate...

  • Page 23

    73d4126 23 dvkst series gas fireplace signature command - check gas pressure and electrical installation figure 26 - signature command wiring diagram cau ti on electrical connections should only be performed by a qualified, licensed electrician. Main power supply must be turned off before connecting...

  • Page 24

    24 73d4126 dvkst series gas fireplace to junction box in fireplace white black white black black white green connector pin to control box ac module { { light rear burner solenoid control box blower right blower left black black fp1915 ac box wiring 8/08 signature command - optional fan blower system...

  • Page 25

    73d4126 25 dvkst series gas fireplace operating instructions - signature command a. This appliance is equipped with an ignition device which automatically lights the pilot. Refer to the instructions for match lighting. B. Before operating smell all around the appliance area for gas. Be sure to smell...

  • Page 26: Operating  Instructions

    26 73d4126 dvkst series gas fireplace signature command - operating instructions fp1913 switch box 8/08 switch box on master switch off fp1914 pilot w sparker 8/08 off on operating instructions 1. Stop! Read the safety information above. 2. This appliance is equipped with an ignition device which au...

  • Page 27

    73d4126 27 dvkst series gas fireplace features command center • easy access function operation and system configura- tion • operation confirmation/fault diagnostic indications (led/ buzzer) • on/off/hi/med/low operation • optional wall mounting control board • electronic ignition • pilot lockout saf...

  • Page 28

    28 73d4126 dvkst series gas fireplace signature command system operation instructions system configuration/setup system configuration/setup is done on the command center. Intermittent/standing pilot setup (default intermittent) 1. Holding the on button on the command center while turning on the mast...

  • Page 29

    73d4126 29 dvkst series gas fireplace signature command system operation instructions functions/operation turning on the fireplace 1. Turn on the master switch and wait for a beep. (green led when a/c power is present.) 2. Press the on button on the command center. Pilot will light and burner will c...

  • Page 30

    30 73d4126 dvkst series gas fireplace remote control operation remote transmitter operations general figure 30 the rfsc remote control has two (2) operating modes: manual and thermostatic. The control system can be set to a temperature range between 45° f and 90° f. The blower speed, light, rear bur...

  • Page 31

    73d4126 31 dvkst series gas fireplace flame height setting for thermostatic mode figure 34 1. Hold auto button for five (5) seconds and one number and flame icon will appear in lcd screen. 2. Use the on / ▲ or off / ▼ button to set the desired flame height to 1 (min.) 2 (medium) or 3 (max.). 3. If t...

  • Page 32

    32 73d4126 dvkst series gas fireplace remote control operation aux control (rear burner shut down) figure 38 1. Press aux button once to turn rear burner off. Aux shows on the lcd. 2. Press aux button again to turn on rear burner. Aux icon disappears. °f fp2149 aux display 12/08 aux fp2149 figure 38...

  • Page 33

    73d4126 33 dvkst series gas fireplace glass removal glass frame removal 1. Remove the plate located in front of the glass at the bottom. 2. Remove rod provided for screen assembly located beneath the cover plate. 3. Rotate the access doors on the right and left side of the glass toward the glass. 4....

  • Page 34

    34 73d4126 dvkst series gas fireplace final installation rock wool placement place rock wool evenly in dime-sized pieces over front and rear burner both in front and behind rear grate. For the middle burner, place the rock wool only on the carry-over areas between the flames. To better enable the ga...

  • Page 35

    73d4126 35 dvkst series gas fireplace log placement log placement 1. From the back side of the unit (with the controls on your left) and holding log #1 in your left hand with the widest end of the log away from you, place the log over the pilot, making sure to locate notches in log over the first ti...

  • Page 36

    36 73d4126 dvkst series gas fireplace log placement 4. Holding log #4 in your left hand with the beveled end down, place the log on the key of log #1 closest to you. Make sure to locate the notch at the beveled end of the log over the third tine from the left. The inside edge of the log should rest ...

  • Page 37

    73d4126 37 dvkst series gas fireplace log placement 7. Hold log #6 in your left hand with the narrow cut end of the “y” toward you and pointing up. Place the log on the key on the top of log #2 with the bottom of the log rest- ing securely on top of the second tine from the left creating a “v” shape...

  • Page 38

    38 73d4126 dvkst series gas fireplace burner flame the flames from the burner should be visually checked as soon as the heater is installed and periodically during normal operation. In normal operation, at full rate, and after operating for about 15 to 30 minutes, the flame should be yellow and slig...

  • Page 39

    73d4126 39 dvkst series gas fireplace cleaning and maintenance vent system the fireplace and venting system should be inspected before initial use and at least annually by a qualified field service person. Inspect the external vent cap on a regular basis to make sure that no debris is interfering wi...

  • Page 40

    40 73d4126 dvkst series gas fireplace troubleshooting operation install batteries and/or plug in the ac board flip the master switch (rocker switch) to the on position press the on button on the command center fault no beep in about 8 seconds no beep or no sound from the valve indicating pilot solen...

  • Page 41

    73d4126 41 dvkst series gas fireplace replacement parts firebox components and accessories item description qty. 500dvkst 1. Bulb 2 73d0020 2. Bulb socket 2 73d4521 3. Glass frame assembly 2 73d0159 4. Junction box assembly (not shown) 1 26d2128 5. Light lens 2 73d0022 6. Access doors 4 73d3258 7. F...

  • Page 42

    42 73d4126 dvkst series gas fireplace replacement parts signature command system 730024 khldv sg parts 12/08 2 22 29, 30 17 13 17 12 13 18 16 15 3 1 5 14 11 4 23 24 25 26 26 27 27 28.

  • Page 43

    73d4126 43 dvkst series gas fireplace replacement parts signature command system item description qty. 500dvkstntsc 500dvkstptsc 1. Gas valve assembly 1 80d0001 80d0002 2. Pilot assembly 1 80d0039 80d0040 3. Control box 1 80d0037 80d0038 4. Ac module 1 scsacm scsacm 5. Command center 1 80d0005 80d00...

  • Page 44

    44 73d4126 dvkst series gas fireplace replacement parts item description qty. 500dvkst 1. Log #1 1 73d4090 2. Log #2 1 73d4091 3. Log #3 1 73d4092 4. Log #4 1 73d4093 5. Log #5 1 73d4094 6. Log #6 1 73d4095 7. Log #7 1 73d4096 8. Log #8 1 73d4097 logs 734126 dvkst log parts.

  • Page 45

    73d4126 45 dvkst series gas fireplace replacement parts accessories 734126 dvkst brick parts 1 2 3 4 5 6 7 8 9 10 herringbone standard item description qty. Part no. 1. Brick, wall eng. Side - cottage red 1 73d4132 2. Brick, wall air side - cottage red 1 73d4133 3. Brick, floor - cottage red 2 73d41...

  • Page 46

    46 73d4126 dvkst series gas fireplace hot 1 2 3 4 5 6 9 7 8 10 730024 khldv vent parts vent components replacement parts.

  • Page 47

    73d4126 47 dvkst series gas fireplace vent components for 5" x 8" replacement parts for more information about, or instructions for, the venting components referenced above, please contact the component manufaturer: selkirk corporation: www. Selkirkcorp.Com or 800-992-8368 simpson duravent: www. Dur...

  • Page 48

    48 73d4126 dvkst series gas fireplace.

  • Page 49

    73d4126 49 dvkst series gas fireplace.

  • Page 50

    50 73d4126 dvkst series gas fireplace requirements for the commonwealth of massachusetts this product must be installed by a licensed plumber or gas fitter when installed within the commonwealth of massachusetts. Note regarding vented products flex line installation must not exceed 36 inches and mus...

  • Page 51

    73d4126 51 dvkst series gas fireplace limited lifetime warranty policy lifetime warranty the following components are warranted for life to the original owner, subject to proof of purchase: firebox, com- bustion chamber, heat exchanger, grate and stainless steel burners. Five year warranty the follo...

  • Page 52

    52 73d4126 dvkst series gas fireplace mhsc 149 cleveland drive • paris, kentucky 40361 www.Mhsc.Com efficiency ratings model energuide ratings d.O.E. Fireplace efficiency (%) (afue%) 500dvkstntsc 77.30 67.40 500dvkstptsc 74.30 66.35.