Majestic DBT33 Installation Instructions & Homeowner's Manual - On/off S

Manual is about: Top Vent Direct Vent Models

Summary of DBT33

  • Page 1

    Installer: do not discard this manual - leave for homeowner 10002789 08/00 rev. 0 i nstallation i nstructions & h omeowner ' s m anual do not store or use gasoline or other flammable vapours and/or liquids in the vicinity of this or any other appliance. For your safety what to do if you smell gas: *...

  • Page 2

    Dbt33/dbt36/dbt39 -2- 10002789/0 t able o f c ontents please read the installation & operating instructions carefully before using the appliance. Important: read all the instructions and warnings carefully before starting the installation. Failure to follow these instructions fully may result in a p...

  • Page 3: & O

    10002789/0 -3- dbt33/dbt36/dbt39 this gas fireplace should be installed by a qualified installer in accordance with local building codes and with current can /cga-b149 (. 1 or .2) installation codes for gas burning fireplaces and equipment. For u.S.A installations follow local codes and/or the current...

  • Page 4

    Dbt33/dbt36/dbt39 -4- 10002789/0 a ppliance d imensions appliance dimensions ref. Dbt33 dbt36 dbt39 a 838 mm (33") 914 mm (36") 991 mm (39") b 733 mm (28.87") 870 mm (34.25") 870 mm (34.25") c 416 mm (16.37") 533 mm (21") 533 mm (21") d 787 mm (31") 838 mm (33") 914 mm (36") e 559 mm (22") 610 mm (2...

  • Page 5

    10002789/0 -5- dbt33/dbt36/dbt39 c learance to c ombustibles appliance top............................. 0 mm (0") bottom ....................... 0 mm (0") side............................ 0 mm (0") back........................... 0 mm (0") venting concentric sections of dv vent top, bottom & sides ....

  • Page 6: & M

    Dbt33/dbt36/dbt39 -6- 10002789/0 f inal f inishing non-combustible materials such as brick or tile may be extended over the edges of the face of the appliance. Do not cover any vent or grille panels. If a trim kit is going to be installed on the fireplace, the brick or tile will have to be installed ...

  • Page 7: On/off S

    10002789/0 -7- dbt33/dbt36/dbt39 g as l ine i nstallation when purging the gas lines, the front glass must be removed. The gas pipeline can be brought in through the rear of the fireplace as well as the bottom. Knockouts are provided on the bottom behind the valve to allow for the gas pipe installati...

  • Page 8: Lp.

    Dbt33/dbt36/dbt39 -8- 10002789/0 c onverting t he a ppliance f rom lp to n atural g as or n atural g as to lp. The dbt33 is convertible between natural gas an lp gas (and vice-versa) with the use of a conversion kit purchased seperately, see your dealer for the correct part number. The dbt36 & 39 ca...

  • Page 9: — T

    10002789/0 -9- dbt33/dbt36/dbt39 a = clearance above grade, veranda, porch, deck, or bal- cony [* 12 inches (305mm) minimum] b = clearance to window or door that may be opened [12" (306mm)]. C = clearance to permanently closed window [minimum 12 inches (305mm) recommended to prevent condensation on ...

  • Page 10

    Dbt33/dbt36/dbt39 -10- 10002789/0 fig. 11 fig. 12 fig. 13 fig. 14 fig. 15.

  • Page 11: Dv C

    10002789/0 -11- dbt33/dbt36/dbt39 h ow t o u se t he v ent g raph the vent chart should be read in conjunction with the follow- ing vent installation instructions to determin the relationship of the vertical and horizontal dimensions of the vent system 1. Determine the height of the centre of the ho...

  • Page 12

    Dbt33/dbt36/dbt39 -12- 10002789/0 v ertical s idewall a pplications since it is very important that the venting system maintain its balance between the combustion air intake and the flue gas exhaust, certain limita- tions as to vent configurations apply and must be strictly adhered to. The vent graph ...

  • Page 13

    10002789/0 -13- dbt33/dbt36/dbt39 v ertical s idewall i nstallations step 1 locate vent opening on the wall. It may be necessary to first position the fireplace and measure to obtain hole location. Depending on whether the wall is combustible or non-combus- tible, cut opening to size. (fig. 22) (for c...

  • Page 14

    Dbt33/dbt36/dbt39 -14- 10002789/0 step 6 use appropriate length of pipe sections - telescopic or fixed - and install the horizontal vent sections. The sections which go through the wall are packaged with the starter kit, and can be cut to suit if necessary. (fig. 26). Sealing vent pipe and firestop ga...

  • Page 15

    10002789/0 -15- dbt33/dbt36/dbt39 do not back fill around snorkel. A clearance of at least 4” must be maintained between the snorkel and the soil if the foundation is recessed, use recess brackets (not supplied) for securing lower portion of the snorkel. Fasten brackets to wall first and then secure ...

  • Page 16: (Dbt33

    Dbt33/dbt36/dbt39 -16- 10002789/0 • 7dvcs must be used to support offsets. (fig. 36)this application will require that you first determine the roof pitch and use the appropriate starter kit. (see venting components list) • the minimum height of the vent above the highest point of penetration through ...

  • Page 17

    10002789/0 -17- dbt33/dbt36/dbt39 v ertical t hrough -t he -r oof i nstallation 1. Locate your fireplace. 2. Plumb to centre of the (4") flue collar from ceiling above and mark position. 3. Cut opening equal to 9-3/8" x 9-3/8" (240 mm x 240 mm). 4. Proceed to plumb for additional openings through the ...

  • Page 18

    Dbt33/dbt36/dbt39 -18- 10002789/0 c rimped e nd v enting c omponents starter kit -model 7dvsk - sidewall venting starter kit - model 7tdvskv - vertical venting for 7tdvskv-a order 1/12 to 6/12 roof pitch for 7tdvskv-b order 7/12 to 12/12 roof pitch for 7tdvskv-f order flat roof starter kit - model 7d...

  • Page 19

    10002789/0 -19- dbt33/dbt36/dbt39 t wist l ock v enting c omponents starter kit -model 7tdvsk - sidewall venting starter kit - model 7tdvskv - vertical venting for 7tdvskv-a order 1/12 to 6/12 roof pitch for 7tdvskv-b order 7/12 to 12/12 roof pitch for 7tdvskv-f order flat roof starter kit - model 7t...

  • Page 20: / F

    Dbt33/dbt36/dbt39 -20- 10002789/0 g eneral o perating i nstructions g lass i nformation only glass approved by cfm majestic inc. Should be used on this fireplace. • the use of any non-approved replacement glass will void all product warranties. • care must be taken to avoid breakage of the glass. • u...

  • Page 21: & L

    10002789/0 -21- dbt33/dbt36/dbt39 i nstallation of l ogs & l ava r ock refer to the log identification chart to identify specific log numbers. 1. Remove the front glass / frame assembly. 2. Remove the logs from their packaging. The logs are fragile and should be handled with care. Keep the packaging m...

  • Page 22: & T

    Dbt33/dbt36/dbt39 -22- 10002789/0 f lame & t emperature a djustment rn/rp & en/ep models for units equipped with ‘hi/lo’ valves the flame adjustment is accomplished by rotating the ‘hi/lo’ adjustment knob located near the centre of the gas control valve, fig. 44 & 45 f lame c haracteristics it is imp...

  • Page 23: Lighting Instructions

    10002789/0 -23- dbt33/dbt36/dbt39 lighting instructions 3. Open control access panel. 4. Push in gas control knob slightly and turn clock- wise to "off". Do not force. 5. Close control access panel. 10. Push the control knob all the way in and hold. Immediately light the pilot by repeatedly depress-...

  • Page 24

    Dbt33/dbt36/dbt39 -24- 10002789/0 trouble shooting the gas control system honeywell millivolt valve.

  • Page 25

    10002789/0 -25- dbt33/dbt36/dbt39 trouble shooting the gas control system sit nova 820 millivolt valve note: before trouble shooting the gas control system, be sure external gas shut off is in the "on" position. Warning: before doing any gas control service work, remove glass front. Symptom possible...

  • Page 26

    Dbt33/dbt36/dbt39 -26- 10002789/0 r eplacement p arts l ist items marked ‘*’ are not shown in the following parts pictorial page. Ref. Description dbt33 dbt36 dbt39 1 log set (complete) 10000470 10000023 10000024 1a log - front left ba2 bb6 bc5 1b log - front right ba3 bb7 bc6 1c log - rear ba4 bb8 ...

  • Page 27

    10002789/0 -27- dbt33/dbt36/dbt39 ref. Description dbt33 dbt36 dbt39 * knob, fan speed control, (fk24 option) 51882 51882 51882 17 fan assembly, with bracket (fk12 option) za1110 za1110 za1110 18 window frame assembly 10001803 10001425 54363 * window glass (with gasket) 10002822 10001781 10002821 * ...

  • Page 28

    Dbt33/dbt36/dbt39 -28- 10002789/0 p arts p ictorial.

  • Page 29: Eb-1 E

    10002789/0 -29- dbt33/dbt36/dbt39 o ptional a ccessories a vailable eb-1 e lectrical b ox the eb-1 electrical junction box when fitted and correctly wired gives an easy and convenient power outlet for the optioal fan kit. If the eb-1 electrical junction box is being fitted the fireplace must be electri...

  • Page 30

    Dbt33/dbt36/dbt39 -30- 10002789/0 w iring i nstructions the fireplace, when installed, must be electri- cally connected and grounded in accordance with local codes or, in the absence of local codes, with the current csa c22.1 canadian electric code. For u.S.A. Installations follow the local codes and...

  • Page 31

    10002789/0 -31- dbt33/dbt36/dbt39 c eramic r efractory k its ceramic refractory panels are available in kit form for the dbt series appliances. Appliance model kit name dbt33 33bdvtcr dbt36 36bdvcr dbt39 39bdvcr take care when handling the refractory panels as they are fragile until held in place an...

  • Page 32

    Dbt33/dbt36/dbt39 -32- 10002789/0 d ecorative b ay w indows bay window kits are available for the dbt33, dbt36 & dbt39 model appliances. When fitting the bay window kits the original front frame/glass assembly must remain in place. The bay window kit is fitted over the existing front glass. Installati...

  • Page 33

    10002789/0 -33- dbt33/dbt36/dbt39.

  • Page 34

    Dbt33/dbt36/dbt39 -34- 10002789/0 !Dmiral"lvds-ississauga/ntario#anada,4.S wwwvermontcastingscom cfm majestic, inc. ©#opyright #&--ajestic)nc "!3)#7!22!.49 4he#&--ajestic)nc˜hereinafterreferredtocollectivelyasthe#ompany warrants that your new 6ermont #astings 'as !Ppliance is free from manufacturing...