Majestic DNE Operating Instructions Manual

Manual is about: designer series direct vent

Summary of DNE

  • Page 1

    Models: (st,pf,cr,cl)dvdnv/dpv, dne/dpe designer series direct vent gas fireplace if the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. – do not store or use gasoline or other flammable vapors and li...

  • Page 2

    53d0419 designer series gas fireplaces contents thank you and congratulations on your purchase of a majestic fireplace. Please read the installation and operation instructions before using the appliance! Important: read all instructions and warnings carefully before starting installation. Failure to...

  • Page 3

    53d0419 designer series gas fireplaces 3 4. Never install the fireplace • in a recreational vehicle • where curtains, furniture, clothing, or other flammable objects are less than 4" from the front, top, or sides of the fireplace • in high traffic areas • in windy or drafty areas 5. This fireplace r...

  • Page 4

    4 53d0419 designer series gas fireplaces important safety information and code approval 14. Do not use any solid fuels (wood, coal, paper, card- board, etc.) in this fireplace. Use only the gas type indicated on rating plate. 15. This appliance, when installed, must be electrically grounded in accor...

  • Page 5

    53d0419 designer series gas fireplaces 5 product features product specifications • this appliance has been certified for use with either natural or propane gas. See appropriate data plates. • this appliance is not for use with solid fuels. • the appliance is approved for bedroom or bedsitting room i...

  • Page 6

    6 53d0419 designer series gas fireplaces 236m” (603 mm) 396 ” (981 mm) 18(6 ” (479 mm) 4(6qe” (113 mm) 2(6qe” (62 mm) 44” (1118 mm) 3456o” (876 mm) 4056qe” (1040 mm) 5/8” (16 mm) 1/2” (13 mm) 326m” (832 mm) cl 5/8” (16 mm) 1/2” (13 mm) 420200 6000dv penin dims 376m” (959 mm) 3256m” (819 mm) 16m” (45...

  • Page 7

    53d0419 designer series gas fireplaces 7 it is best to build firebox framing after the appliance is set in place. Refer to the dimensions for your fireplace on page 7. The framing headers may rest on the top of the firebox standoffs. The firebox may be installed directly on a combustible floor or ra...

  • Page 8

    8 53d0419 designer series gas fireplaces framing see through fireplace * note: for ease of installation, frame around the firebox after it has been set. Refer to chart below for specifications. When installing into existing framed (a1) openings, loosen the junction box. Remove the rear-mounted flue ...

  • Page 9

    53d0419 designer series gas fireplaces 9 installation information this gas fireplace should be installed by a qualified installer in accordance with local building codes and with current csa-b149 (.1 or .) installation codes for gas burning fireplaces and equipment. If the unit is being installed in...

  • Page 10

    10 53d0419 designer series gas fireplaces a. Wall location y minimum distance between a glass panel and a parallel wall = 4" z minimum distance between the edge of a glass panel and an adjacent wall = 3" b. Island location x (maximum length of horizontal venting = 0'. Refer to the venting section of...

  • Page 11

    53d0419 designer series gas fireplaces 11 optional top vent installation optional top vent application the appliance is shipped as a rear vent unit. If the installa- tion layout requires the unit to be a top vent configuration the appliance can be converted by following the steps below. When removin...

  • Page 12

    1 53d0419 designer series gas fireplaces installation precautions note: this appliance must be installed with an vermont castings group approved venting system only. Consult local building codes before beginning the installation. The installer must make sure to select the proper vent system for inst...

  • Page 13

    53d0419 designer series gas fireplaces 13 venting installation installation planning there are two basic types of direct-vent installation: • horizontal termination • vertical termination it is important to select the proper length of vent pipe for the type of termination you choose. It is also impo...

  • Page 14

    14 53d0419 designer series gas fireplaces venting installation v x x x d e b b b c b m b a j k f l vent termination air supply inlet area where terminal is not permitted h i fixed closed operable operable fixed closed b cfm145a dv termin location 5/01/01 rev. 12/05/01 sta inside corner detail a g cf...

  • Page 15

    53d0419 designer series gas fireplaces 15 venting installation how to use the vent graph the vent graph should be read in conjunction with the following vent installation instructions to determine the relationship between the vertical and horizontal dimensions of the vent system. 1. Determine the he...

  • Page 16

    16 53d0419 designer series gas fireplaces rear wall vent installation when installed as a rear vent unit this appliance may be vented directly to a termination located on the rear wall behind the appliance • the maximum horizontal distance between the rear of the appliance and the outside face of th...

  • Page 17

    53d0419 designer series gas fireplaces 17 venting installation 4. Apply a bead of non-hardening mastic around the outside edge of vent cap. Position the vent cap in the center of hole on the exterior wall with the word “up” on the vent cap facing up. Insure proper clearance of 1" to combustibles is ...

  • Page 18

    18 53d0419 designer series gas fireplaces venting installation horizontal termination configura- tions since it is very important that the venting system main- tain its balance between the combustion air intake and the flue gas exhaust, certain limitations as to vent con- figurations apply and must ...

  • Page 19

    53d0419 designer series gas fireplaces 19 • if a 90° elbow is used in the horizontal vent run, the hori- zontal vent length is reduced by 36" (914 mm). Figure 26. This does not apply if the 90° elbows are used to increase or redirect a vertical rise. Figure 26 example: according to the vent graph, f...

  • Page 20

    0 53d0419 designer series gas fireplaces venting installation below grade installations when it is not possible to meet the required vent terminal clearances of 1" above grade level, a snorkel kit is recom- mended. It allows installation depth down to 7" (178 mm) below grade level. The 7" (178 mm) i...

  • Page 21

    53d0419 designer series gas fireplaces 1 vertical through-the-roof applica- tions this gas fireplace has been approved for, • vertical installations up to 40' (1 m) in height. Up to a 10' (3 m) horizontal vent run can be installed within the vent system using a maximum of two 90° elbows. Figure 31 v...

  • Page 22

    53d0419 designer series gas fireplaces venting installation flat ceiling installation 1. Cut a 9z\x" (41 mm) square hole in the ceiling using the locating hole as a center point the opening should be framed to 9z\x" x 9z\x" (41 x 41 mm) inside dimensions as shown in figure 34 using framing lumber th...

  • Page 23

    53d0419 designer series gas fireplaces 3 fireplace installation check gas type use proper gas type for the fireplace you are installing. If you have conflicting gas type, do not install fireplace. See dealer where you purchased the fireplace for proper fireplace for your gas type or conversion kit. ...

  • Page 24

    4 53d0419 designer series gas fireplaces note : the gas line connection may be made using 1 / " rigid tubing or an approved flex connector. Since some municipalities have additional local codes it is always best to consult your local authorities and the current edition of the national fuel gas code ...

  • Page 25

    53d0419 designer series gas fireplaces 5 1. Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is different from the fireplace, stop! Do not install the appliance. Contact your dealer immediately. . To ease installation, a 30" (76 mm) flex li...

  • Page 26

    6 53d0419 designer series gas fireplaces electrical installation fp2551 remote switch wiring remote wall mounted switch a remote wall switch and up to fifteen (15) feet of 18 ga. Wire may be used with this appliance. Attach the wall switch in a junction box at the desired location on the wall. Figur...

  • Page 27

    53d0419 designer series gas fireplaces 7 glass removal glass frame removal all three (3) glass frames are replaced the same way. 1. Release two clamps on bottom of fireplace. Figure 41 . Tilt glass frame out and lift glass frame up until it clears three tabs on top of fireplace. 3. Set glass frame a...

  • Page 28

    8 53d0419 designer series gas fireplaces log placement install logs and rock wool (ember material) in firebox 1. Remove glass frame. Refer to glass frame removal, page 31. . Carefully remove logs from wrapping. 3. Place left log (#1) on left end of grate. Line up two () pin holes in bottom of log wi...

  • Page 29

    53d0419 designer series gas fireplaces 9 lg640 dv6000 bot ctr back log figure 44 - install bottom center log (#3) bottom center back log (#3) pin lg640 lg642 dv6000 left top log 5. Position left end of bottom center back log (#3) beside rear end of left log (#1). Line up pin on grate with pin hole i...

  • Page 30

    30 53d0419 designer series gas fireplaces lg644 dv6000 rockwool log placement figure 48 - rock wool placement (right corner model shown) 8. Place y-shaped end of top log (#6) on on prong four of back of grate. Position other end of top log (#6) in cutout of bottom center log (#3). Figure 47 rock woo...

  • Page 31

    53d0419 designer series gas fireplaces 31 air restrictor adjustment the fireplace is equipped with a restrictor plate that is located inside the top chamber of the fireplace. Depending upon the vent configuration, you may be required to adjust the restrictor position 1. Remove glass frame. Refer to ...

  • Page 32

    3 53d0419 designer series gas fireplaces operating instructions a. This appliance is equipped with a pilot which must be lit with built-in battery ignitor while following these instructions exactly. B. Before operating smell all around the appliance area for gas. Be sure to smell next to the floor b...

  • Page 33: Pilot

    53d0419 designer series gas fireplaces 33 operating instructions pilot of f p il o t on fp1935 control knob pilot continued on next page approved leak testing method you may check for gas leaks with the following methods only: • soap and water solution • an approved leak testing spray • electronic s...

  • Page 34: Pilot

    34 53d0419 designer series gas fireplaces operating instructions pilot of f pilot o n of f pilo t on pilot fp1937 control knob on pilot of f p il o t on fp1935 control knob pilot off on rs lighting burner main burner switch the “on/off/rs” switch for the main burner can be found behind door of the f...

  • Page 35

    53d0419 designer series gas fireplaces 35 cleaning and maintenance make sure the gas valve knob is in the “off” position. Wait at least five (5) minutes before starting maintenance. Fireplace must be cold before starting maintenance. Venting system a qualified agency should examine the venting syste...

  • Page 36

    36 53d0419 designer series gas fireplaces troubleshooting standing pilot ignition symptom possible cause action 1. Spark ignitor will not light pilot after repeated triggering of piezo. . Pilot will not stay lit after carefully follow- ing lighting instruc- tions. 3. Pilot burning, valve knob turned...

  • Page 37

    53d0419 designer series gas fireplaces 37 troubleshooting electronic ignition start 1. Turn gas supply off. . Turn on/off switch to “on” power to module (4v normal) yes is there a spark across ignitor sensor gap? Yes turn on gas. Does pilot burner light? Yes does spark stop when pilot is lit? Yes do...

  • Page 38

    38 53d0419 designer series gas fireplaces troubleshooting general troubleshooting glass replacement and blower • never operate fireplace if glass is broken. • replace any glass that is chipped, cracked, or broken. Replacement glass assemblies must be supplied by fireplace manufacturer — no substitut...

  • Page 39

    53d0419 designer series gas fireplaces 39 replacement parts ref. Description qty natural propane 1. Junction box 1 6d18k 6d18k . Large glass assy 1* 4d0364k 4d0366k (peninsula, see-through) . Large glass assy 1* 4d0366k 4d0366k (corner left, corner right) 3. Small glass assy 1 4d0365k 4d0365k (penin...

  • Page 40

    40 53d0419 designer series gas fireplaces standing pilot – millivolt control replacement parts 1 2c 2i 2t 2 4 5 6 3 7 8 9,10,11,12 420200 dv6000 millivolt parts ref. Description qty natural propane 1. Gas valve assy 1 37d0117 37d0118 . Pilot assy 1 0h048 0h049 c. Replacement thermocouple 1 37d1067 3...

  • Page 41

    53d0419 designer series gas fireplaces 41 electronic ignition replacement parts 1 3 4 5 7 8 9 lo hi 2 24v #6 24v gnd #5 pv #3 mv/pv #2 mv #1 gnd (burner) #4 sense #8 s p ark #9 420200 dv6000 elect parts 6 ref. Description qty natural propane 1. Gas valve assy 1 37d0016 37d0017 . Pilot assy 1 37d000 ...

  • Page 42

    4 53d0419 designer series gas fireplaces replacement parts logs ref. Description qty natural propane 1. Left bottom log, #1 1 4d0401 4d0401 . Right bottom log, # 1 4d0400 4d0400 3. Bottom center log, #3 1 4d0403 4d0403 4. Bottom front log, #4 1 4d040 4d040 5. Left top log, #5 1 4d0404 4d0404 6. Top ...

  • Page 43

    53d0419 designer series gas fireplaces 43 venting components hot 1 2 3 4 5 6 9 7 8 11 10 420200 dv6000 vent components current old duravent duravent or vermont or vermont qty./ castings group castings group selkirk metal-fab item box description part no. Part no. Part no. Part no. 1 1 thru-roof flex...

  • Page 44

    44 53d0419 designer series gas fireplaces.

  • Page 45

    53d0419 designer series gas fireplaces 45.

  • Page 46

    46 53d0419 designer series gas fireplaces note regarding vented products this product must be installed by a licensed plumber or gas fitter when installed within the commonwealth of massachusetts. Any residence with a direct vent product must have a co detector installed in the residence. Installati...

  • Page 47

    53d0419 designer series gas fireplaces 47 limited lifetime warranty policy lifetime warranty the following components are warranted for life to the original owner, subject to proof of purchase: firebox, combustion chamber, heat exchanger, grate and stainless steel burners. Five year warranty the fol...

  • Page 48

    Efficiency ratings model energuide ratings fireplace efficiency (%) stdvdnv 6.8 pfdvdnv 6.8 crdvdnv 6.8 cldvdnv 6.8 stdvdne 65.1 pfdvdne 65.1 crdvdne 65.1 cldvdne 65.1 stdvdpv 70.6 pfdvdpv 70.6 crdvdpv 70.6 cldvdpv 70.6 stdvdpe 73.4 pfdvdpe 73.4 crdvdpe 73.4 cldvdpe 73.4 based on csa p.4.1-09 vermon...