Majestic DVR33 Installation Instructions & Homeowner's Manual

Summary of DVR33

  • Page 1

    Installer: do not discard this manual - leave for homeowner 10002823 9/00 rev. 0 i nstallation i nstructions & h omeowner ' s m anual do not store or use gasoline or other flammable vapours and/or liquids in the vicinity of this or any other appliance. For your safety what to do if you smell gas: * ...

  • Page 2

    Vermont castings, majestic products 2 dvr33 10002823/0 t able o f c ontents thank you & congratulations on your purchase of a vermont castings, majestic products fireplace. Please read the installation & operating instructions carefully before using the appliance. Important: read all the instruction...

  • Page 3

    10002823/0 dvr33 3 vermont castings, majestic products a ppliance i nstallation i nstructions this gas replace should be installed by a qualied installer in accordance with local building codes and with current can /cga-b149 (. 1 or .2) installation codes for gas burning fireplaces and equipment. ...

  • Page 4: & F

    Vermont castings, majestic products 4 dvr33 10002823/0 a ppliance & f raming d imensions a b c d e f g h i j k l l m n o p q appliance dimensions dvr33 a 838 mm 33" b 733 mm 28-7/8" c 416 mm 16-3/8" d 787 mm 31" e 560 mm 22-1/16" f 292 mm 11-1/2" g 375 mm 14-3/4" h 622 mm 24-1/2" i 127 mm 5" j 191 m...

  • Page 5

    10002823/0 dvr33 5 vermont castings, majestic products c learance to c ombustibles appliance top.................................... 0 mm (0") bottom .............................. 0 mm (0") vent end ........................... 0 mm (0") non-vent end.................... 0 mm (0") venting concentric ...

  • Page 6

    Vermont castings, majestic products 6 dvr33 10002823/0 f inal f inishing non-combustible materials such as brick or tile may be extended over the edges of the face of the appliance. Do not cover any vent or grille panels. If a trim kit is going to be installed on the replace, the brick or tile will...

  • Page 7: On/off S

    10002823/0 dvr33 7 vermont castings, majestic products r emote on/off s witch installation 1. Thread the wiring through the holes on the end panels of the appliance. Take care not to cut the wire or insulation on metal edges. Route the wire to a conveniently located receptacle box. 2. Attach the wir...

  • Page 8: Lp.

    Vermont castings, majestic products 8 dvr33 10002823/0 c onverting t he a ppliance f rom lp to n atural g as or n atural g as to lp. This appliance can be converted from natural gas to lp gas (or lp to natural) with the use of an approved conversion kit. The kits are specic to individual appliances...

  • Page 9

    10002823/0 dvr33 9 vermont castings, majestic products fig. 10

  • Page 10: — T

    Vermont castings, majestic products 10 dvr33 10002823/0 v v v v v v v v v x x x d e b b b c b m b a j k a f l g g termination cap air supply inlet gas meter restricted area (termination prohibited) h i fixed closed fixed closed openab le openable fixed closed g g n n a = clearance above grade, veran...

  • Page 11

    10002823/0 dvr33 11 vermont castings, majestic products outside corner inside corner termination clearances termination clearances for buildings with combustible and noncombustible exteriors. A = combustible 6"(152mm) noncombustible 2"(50mm) b = combustible 6"(152mm) noncombustible 2"(50mm) a balcon...

  • Page 12

    Vermont castings, majestic products 12 dvr33 10002823/0 v enting i nstallation i nstructions g eneral i nformation o n a ssembling t he v ent p ipes i n d irect v ent a pplications . Crimped end pipes before joining elbows and pipes apply a bead of high tempera- ture sealant to the crimped end of th...

  • Page 13

    10002823/0 dvr33 13 vermont castings, majestic products r ear w all v ent i nstallation step 1 locate and cut the vent opening in the wall, fig. 15 for combustible walls rst frame in opening, fig. 15. Combustible walls : cut a 10-3/8"h x 9-3/8"w (265 mm x 240 mm) hole through the exterior wall and ...

  • Page 14

    Vermont castings, majestic products 14 dvr33 10002823/0 h ow t o u se t he v ent g raph the vent graph should be read in conjunction with the follow- ing vent installation instructions to determine the relationship between the vertical and horizontal dimensions of the vent system. 1. Determine the h...

  • Page 15

    10002823/0 dvr33 15 vermont castings, majestic products • if a 90º elbow is tted directly onto transition elbow attached to the appliance ange the maximum horizontal vent run before the termination or a vertical rise is 36" (914 mm), fig. 19. • if a 90º elbow is used in the horizontal vent run (le...

  • Page 16

    Vermont castings, majestic products 16 dvr33 10002823/0 v ertical s idewall i nstallations step 1 locate vent opening on the wall. It may be necessary to rst position the replace and measure to obtain hole location. Depending on whether the wall is combustible or non-combus- tible, cut opening to ...

  • Page 17

    10002823/0 dvr33 17 vermont castings, majestic products of the exterior wall. See the sidewall vent graph for extended horizontal run if the vertical exceeds 24”. 1 establish vent hole through the wall (fig. 22). 2 remove soil to a depth of approximately 16" (405 mm) below base of snorkel. Install d...

  • Page 18

    Vermont castings, majestic products 18 dvr33 10002823/0 • up to two 45º elbows may be used within the horizontal run. For each 45º elbow used on the horizontal level the maximum horizontal length must be reduced by 18" (457 mm). Example: maximum horizontal length 0 x 45º elbows = 10' (3.1 m) 1 x 45º...

  • Page 19

    10002823/0 dvr33 19 vermont castings, majestic products v ertical t hrough -t he -r oof i nstallation 1. Locate your replace. 2. Plumb to centre of the 4" (100 mm) ue collar from the ceiling above and mark the position. 3. Cut an opening equal to 9-3/8" x 9-3/8" (240 mm x 240 mm). 4. Proceed to pl...

  • Page 20

    Vermont castings, majestic products 20 dvr33 10002823/0 t wist l ock v enting c omponents 7dvrvt - through the wall rear vent termination starter kit -model 7tdvsk - sidewall venting starter kit - model 7tdvskv - vertical venting for 7tdvskv-a order 1/12 to 6/12 roof pitch for 7tdvskv-b order 7/12 t...

  • Page 21

    10002823/0 dvr33 21 vermont castings, majestic products c rimped e nd v enting c omponents 7dvrvt - through the wall rear vent termination starter kit -model 7dvsk - sidewall venting starter kit - model 7tdvskv - vertical venting for 7dvskv-a order 1/12 to 6/12 roof pitch for 7dvskv-b order 7/12 to ...

  • Page 22

    Vermont castings, majestic products 22 dvr33 10002823/0 g eneral o perating i nstructions g lass i nformation only glass approved by vermont castings, majestic products should be used on this re- place. • the use of any non-approved replacement glass will void all product warranties. • care must be...

  • Page 23: & T

    10002823/0 dvr33 23 vermont castings, majestic products i nstallation of the l ogs & l ava r ock m aterial refer to fig. 37 for log identication during this procedure. 1. Remove the front glass/frame assembly. 2. Remove the logs from their packaging the logs should be handled with care as the mater...

  • Page 24: Lighting Instructions

    Vermont castings, majestic products 24 dvr33 10002823/0 lighting instructions 3. Open control access panel. 4. Push in gas control knob slightly and turn clock- wise to "off". Do not force. 5. Close control access panel. 10. Push the control knob all the way in and hold. Immediately light the pilot ...

  • Page 25

    10002823/0 dvr33 25 vermont castings, majestic products trouble shooting the gas control system honeywell millivolt valve.

  • Page 26

    Vermont castings, majestic products 26 dvr33 10002823/0 trouble shooting the gas control system sit nova 820 millivolt valve note: before trouble shooting the gas control system, be sure external gas shut off is in the "on" position. Warning: before doing any gas control service work, remove glass f...

  • Page 27

    10002823/0 dvr33 27 vermont castings, majestic products r eplacement p arts l ist items marked ‘*’ are not shown in the following parts pictorial page. Dvr33 ref. Description part number 1 log set (complete) 10002729 1a log - left rear a22 1b log - right rear a23 1c log - left front a24 1d log - rig...

  • Page 28

    Vermont castings, majestic products 28 dvr33 10002823/0 * electric cord, fk 24 option 51865 * fan temperature sensor, fk24 option 51704 * fan speed control, fk24 option 51738 * knob, fan speed control, fk24 option 51882 19 fan assembly, with bracket, fk12 option za1110 20 window frame assembly 10001...

  • Page 29

    10002823/0 dvr33 29 vermont castings, majestic products p arts p ictorial l o h i pilot adj pil ot o n off 1a 1b 1c 1d 1e 2 3a/b 4a/b 5 6 7 8 9 10 10 11 12 13 14 15 16a/b 17a/b 18 19 20 21 22 23 24 25 26 27 2a.

  • Page 30

    Vermont castings, majestic products 30 dvr33 10002823/0 o ptional a ccessories a vailable f an k its fk24 fan assembly this auxiliary fan system increases the efciency of the circu- lation of the heating air. The fk24 fan kit allows variable speed control of the circula- tion fan and also incorpora...

  • Page 31

    10002823/0 dvr33 31 vermont castings, majestic products 3 the second terminal of the speed control unit is attached to either terminal of the thermal sensor. 4 the second terminal of the thermal sensor is connected to either terminal of the fan motor. 5 the second fan motor terminal is connected to ...

  • Page 32

    Vermont castings, majestic products 32 dvr33 10002823/0 r emote c ontrols optional remote control units are available to control different functions of the appliance. Model function/s controlled mrc1 on/off mrc2 on/off and temperature mrc3 on/off and temperature control with a digital display and a ...