Majestic Fireplaces DVRTSB Installation And Operating Manual

Manual is about: Bay Window Rear/Top Convertible Direct Vent Fireplaces

Summary of DVRTSB

  • Page 1

    Homeowner’s installation and operating manual design certified 10003848 1/07 rev. 3 warning! If the information in this manual is not followed exactly, a fire or explosion may result, causing property damage, personal injury or loss of life. What to do if you smell gas: • do not try to light any app...

  • Page 2: Table of Contents

    2 dvrtsb bay window fireplace 10003848 installation & operating instructions important curing/burning instructions .................................................................................3 fireplace dimensions ....................................................................................

  • Page 3

    3 dvrtsb bay window fireplace 10003848 this appliance may be installed in an aftermarket permanently located, manufactured home or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible fo...

  • Page 4

    4 dvrtsb bay window fireplace 10003848 e f f g g c d rough opening height b a 1¹⁄₂" dia. I h j k - rough opening depth m - rough opening width 7/8" dia. 5⁷⁄₁₆" (138mm) 3⁷⁄₈" (99mm) 4¹⁄₈" (105mm) 2³⁄₈" (60mm) 3848 dvrtsb top vent specs 7/03 l fireplace dimensions (installed as top vent) gas line inle...

  • Page 5

    5 dvrtsb bay window fireplace 10003848 c d rough opening height b a 1¹⁄₂" dia. I h j k - rough opening depth m - rough opening width e f f g g 7/8" dia. 5⁷⁄₁₆" (138mm) 3⁷⁄₈" (99mm) 4¹⁄₈" (105mm) 2³⁄₈" (60mm) 3848 dvrtsb rear vent specs 7/03 l fireplace dimensions (installed as rear vent) 3848 gas li...

  • Page 6

    6 dvrtsb bay window fireplace 10003848 top of unit to ceiling ......................................... 36” (914 mm) front of unit to combustibles ............................ 36” (914 mm) appliance top .................................................. (0”) 0 mm to stand-off bottom ...................

  • Page 7

    7 dvrtsb bay window fireplace 10003848 if a trim kit is going to be installed on the fireplace, the brick or tile will have to be installed flush with the edges of the appliance. Final finishing noncombustible materials such as brick or tile may be extended over the edges of the face of the appliance....

  • Page 8

    8 dvrtsb bay window fireplace 10003848 the fireplace, when installed, must be elec- trically connected and grounded in accord- ance with local codes or, in the absence of local codes, with the current csa c22.1 canadian electrical code for usa installations follow the local codes and the national ele...

  • Page 9

    9 dvrtsb bay window fireplace 10003848 this appliance is shipped as a rear vent unit. If the installation layout requires the unit to be a top vent con- figuration the appliance can be converted by following the steps below. When removing and refitting the plates and adapter be sure the associated gas...

  • Page 10

    10 dvrtsb bay window fireplace 10003848 general venting information – termination location your fireplace is approved to be vented either through the rear wall or the vertical side wall, or vertical through the roof. • only venting components specifically approved and labeled for this fireplace may be ...

  • Page 11

    11 dvrtsb bay window fireplace 10003848 v v v v v v v x x x d e b b b c b m b a j k f l vent termination air supply inlet area where terminal is not permitted h i operable operable fixed closed v b cfm145a dv termin location 5/01/01 rev. 12/05/01 sta inside corner detail v a g n n cfm14...

  • Page 12

    12 dvrtsb bay window fireplace 10003848 general information for connecting vent pipes fig. 12a termination clearances. Canadian installations: venting system must be installed in accordance with the current csa-b149.1 installation code. Usa installations: the venting system must conform with local c...

  • Page 13

    13 dvrtsb bay window fireplace 10003848 the vent chart should be read in conjunction with the following vent installation instructions to determine the relationship of the vertical and horizontal dimensions of the vent system. 1. Determine the height of the center of the horizontal vent pipe exiting...

  • Page 14

    14 dvrtsb bay window fireplace 10003848 step 5 guide the vent through the vent hole as you place the appliance in its installed position. Guide the 4” (102mm) and 7” (175 mm) collars of the vent termination into the outer ends of the venting. Do not force the termination. If the vent pipes do not al...

  • Page 15

    15 dvrtsb bay window fireplace 10003848 • the maximum number of 90° elbows per side wall installation is three (3). • if a 90° elbow is fitted directly on top of the fireplace flange, the maximum horizontal vent run before the termination or a vertical rise is 36” (914 mm). Max. 20" (508mm) max. 36" (9...

  • Page 16

    16 dvrtsb bay window fireplace 10003848 step 2 measure wall thickness and cut zero clearance sleeve parts to proper length (maximum 12”/305 mm). As- semble sleeve and attach to firestop with #8 sheet metal screws (supplied). Install firestop assembly. (fig. 24) zero clearance sleeve is only required f...

  • Page 17

    17 dvrtsb bay window fireplace 10003848 below grade installation when it is not possible to meet the required vent ter- minal clearances of 12” (305 mm) above grade level a starter kit is recommended. It allows installation depth of down to 7” (178 mm) below grade level. The 7” (178mm) is measured f...

  • Page 18

    18 dvrtsb bay window fireplace 10003848 1. Locate your fireplace. 2. Plumb to center of the (4”) flue collar from ceiling above and mark position. 3. Cut opening equal to 9³⁄₈” x 9³⁄₈” (240 x 240 mm). 4. Proceed to plumb for additional openings through the roof. In all cases, the opening must provide ...

  • Page 19

    19 dvrtsb bay window fireplace 10003848 if there is a room above ceiling level, firestop spacer must be installed on both the bottom and the top side of the ceiling joists. (fig. 34) if an attic is above ceiling level a 7dvais (attic insulation shield) must be installed. Twl101a twist lock pipe 2/8/9...

  • Page 20

    20 dvrtsb bay window fireplace 10003848 twist lock venting components starter kit-model 7tdvsk-sidewall/rearwall venting starter kit-model 7tdvskv-vertical venting for 7tdvskv-a order 1/12 to 6/12 roof pitch for 7tdvskv-b order 7/12 to 12/12 roof pitch for 7tdskv-f order flat roof starter kit-model 7...

  • Page 21: Operating Instructions

    21 dvrtsb bay window fireplace 10003848 only glass approved by cfm corporation should be used on this fireplace. • the use of any non-approved replacement glass will void all product warranties. • care must be taken to avoid breakage of the glass. • under no circumstances should this appliance be ope...

  • Page 22

    22 dvrtsb bay window fireplace 10003848 it is necessary to periodically clean glass. During start- up condensation, which is normal, forms on the inside of the glass. This condensation causes lint, dust and other airborne particles to cling to glass surface. Also initial paint curing may deposit a s...

  • Page 23

    23 dvrtsb bay window fireplace 10003848 lg299 ceramic ember rock location fig. 40 location of log cradle prongs in relation to assembled logs. Your log set contains two types of “lava rocks”. The placement of this material is best done after the logs have been installed. Ceramic ember rocks (pt. # 5...

  • Page 24

    24 dvrtsb bay window fireplace 10003848 3. Open control access panel. 4. Push in gas control knob slightly and turn clock- wise to “off”. Do not force. 5. Close control access panel. 1. Stop! Read the safety information above. 2. Turn off all electrical power to the fireplace. 3. For mn/mp/tn/tp appl...

  • Page 25

    25 dvrtsb bay window fireplace 10003848 warning: before doing any gas control service work, remove glass front. Symptom possible causes corrective action 1. Spark ignitor will not light a. Defective or misaligned using a match, light pilot. If pilot lights, turn off electrode at pilot. Pilot and pus...

  • Page 26

    26 dvrtsb bay window fireplace 10003848 troubleshooting the gas control system honeywell millivolt valve start check gas supply on ▼ ▼ ▼ ▼ ▼ pilot lights with piezo ignitor • lockout has engaged. Wait 60 seconds and try again. • for spark at electrode while depressing piezo 1/8" gap to pilot hood ne...

  • Page 27

    27 dvrtsb bay window fireplace 10003848 fuel conversion instructions the conversion of this appliance from one gas to another must be carried out by a qualified service technician. 1. Disconnect power to unit and shut off the gas supply. 2. Remove the glass (refer to “glass removal” sec- tion.) 3. Ca...

  • Page 28: Maintenance

    28 dvrtsb bay window fireplace 10003848 maintenance burner and burner compartment it is important to keep the burner and the burner compartment clean. At least once per year the logs and lava rock/ember material should be removed and the burner compartment vacuumed and wiped out. Remove and replace ...

  • Page 29: Dvrtsb

    29 dvrtsb bay window fireplace 10003848 1 a f b d e c 4 5 9a,b 19 21 22 10a,b 21 12 20 11 l ohi pilot adj pilot on off 23 25a,b 24 26a,b 28 33 27 40 46 47 48 51 49 50 52 38 62 39 42 37 63 41 63 36 3848 dvrtsb parts 7/03 cfm corporation reserves the right to make changes in design, materials, specific...

  • Page 30: Dvrtsb

    30 dvrtsb bay window fireplace 10003848 dvrtsb (continued) ref. Description dvrtsb 1e. Log - front center b109 1f. Log - rear center b110 2. Lava rock package (not shown) 10001454 3. Ceramic lava rock package (not shown) 57897 4. Grate assembly, black 10003850 5. Burner housing assembly w/tiles 1000...

  • Page 31: Dvrtsb

    31 dvrtsb bay window fireplace 10003848 dvrtsb (continued) ref. Description dvrtsb 39. Louvre assembly, front bottom 10003880 40. Hinge, lower louvre assembly 52356 41. Window frame assembly side 10003859 42. Window frame assembly front 10003843 43. Window glass (complete with gasket), side (not sho...

  • Page 32: Optional Accessories

    32 dvrtsb bay window fireplace 10003848 fk24 fan assembly this auxiliary fan system increases the efficiency of the circulation of the heating air. The fk24 fan kit allows variable speed control of the circulation fan and also incorporates a heat sensor in the circuit. Specifications 115 volt / 60hz /...

  • Page 33

    33 dvrtsb bay window fireplace 10003848 remote controls optional remote control units are available to control different functions of the appliance. Model function/s controlled rc1 on/off rc2 on/off and temperature imtfk wall mounted thermostat control. Black white ground fp394 wiring diagram 11/20/...

  • Page 34

    34 dvrtsb bay window fireplace 10003848.

  • Page 35

    35 dvrtsb bay window fireplace 10003848 basic warranty the cfm corporation company (hereinafter referred to collectively as the company) warrants that your new vermont castings or majestic gas fireplace/stove is free from manufacturing and material defects for a period of one year from the date of p...

  • Page 36

    Efficiency ratings model energuide ratings steady state (%) d.O.E. Fireplace efficiency (%) fan-off fan-on (afue%) dvrtsb rn 58.4 81 82 64 dvrtsb rp 58.4 82 83 64 dvrtsb rfn 58.4 81 82 64 dvrtsb rfp 58.4 82 83 64 dvrtsb en 60.4 81 82 64 dvrtsb ep 60.4 82 83 64 410 admiral blvd. • mississauga, ontario,...