Majestic Fireplaces FireStage UVHK23RP Installation And Operating Instructions Manual - Important Safeguards

Other manuals for FireStage UVHK23RP: Brochure & Specs

Summary of FireStage UVHK23RP

  • Page 1

    Installation and operating instructions for unvented gas log heaters models: uvhk23rp, uvhk29rn, uvhk31rp, uvhk36rn models with “n” after the model number use natural gas; models with “p” after the model number use propane (lp) gas. Read and save these instructions this appliance operates as an unve...

  • Page 2: Table of Contents

    2 20008055 minimum dimensions for existing solid fuel burning fireplaces ............................................. 3 important information ................................................................................................................4 important safeguards .........................

  • Page 3

    3 20008055 minimum dimensions for existing solid fuel burning fireplaces vent free or decorative appliance log set btu/hr model nominal size fuel high low uvhk36rn 24” nat 39,000 28,000 uvhk31rp 24” lp 31,000 20,000 uvhk29rn 18” nat 29,000 14,000 uvhk23rp 18” lp 23,000 14,000 b a c t104 min. Dims 10...

  • Page 4: Important Information

    4 20008055 this appliance may be installed in an aftermarket, perma- nently located, manufactured (mobile) home, where not prohibited by local codes. This appliance is only for use with the type of gas indi- cated on the rating plate. This appliance is not convertible for use with other gases. Insta...

  • Page 5: Important Safeguards

    5 20008055 the national fuel gas code, ansi z223.1/nfpa 54 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 btu per hour (4.8m 3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not le...

  • Page 6

    6 20008055 provisions for adequate combustion and ventilation air warning: this heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate com- bustion and ventilation air. Today’s homes are built more energy efficient than ever. New m...

  • Page 7

    7 20008055 l w d t104 flue damper 10/27/03 djt flue damper closed for unvented operation and maximum heat output flue damper locked open to a minimum venting area of 34 sq. In. (for areas where unvented products are not permitted) note: for round flue opening minimum flue diameter (d) - 7”. For square...

  • Page 8: Installation

    8 20008055 installation unpacking open the cartons and remove the logs and the chassis. Re- move each of the logs by gripping at either end of the log while avoiding any undue pressure. Please note that the logs have been marked for positive identification. The cartons for all models contain the foll...

  • Page 9

    9 20008055 installation of wrst or wrd wireless remote to begin installation of your wireless remote (wrd or wrst), you must first remove the two screws retaining the cover for the ignitor/receiver delete plate as shown on the log set in figure 5, letter “e”. This allows the removal of the delete pla...

  • Page 10

    10 20008055 t111 bottom view 10/27/03 djt c b switch bottom view t111 fig. 7 route thermostat wire under logset. T110 remote install 10/27/03 djt a b c d e f g h b t110 fig. 6 wireless remote receiver installation. A piezo ignitor e battery terminal b mounting screws f receiver bracket c lead wires ...

  • Page 11

    11 20008055 gas connection check gas type. Use only the gas type indicated on the heater’s rating plate. If the gas type indicated on the plate is not your type of gas supply, do not install. Contact your dealer for the proper model. Warning danger of property damage, bodily injury or death. Make su...

  • Page 12

    12 20008055 check the tags on the unit to verify the gas type of the log set. If you connect natural gas to an lp gas unit, you may be un- able to ignite the pilot. If the pilot does ignite, the front burner flame on the low setting will be bright blue but only 1/4” to 1/2” long and most likely lifti...

  • Page 13: Gas Line Pipe Sizing

    13 20008055 note: to determine the size of the branch gas line from the main gas line to the fireplace, enter the tables below (for iron pipe or copper tubing) using the distance from the gas meter or second stage regulator to the furthest appliance on the gas system. Select a pipe or tube diameter w...

  • Page 14

    14 20008055 for your safety, read before lighting warning: if you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instr...

  • Page 15

    15 20008055 for your safety, read before lighting warning: if you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instr...

  • Page 16

    16 20008055 match lighting if the pilot cannot be ignited with the piezo, it can be manually lit with the use of a match and lighter rod. 1. Place the match in the holder and light. With the right hand, depress and turn the control knob counterclockwise (fig. 17) to the “pilot” position. Hold in for...

  • Page 17

    17 20008055 positioning logs the logs must be positioned only as illustrated in figures 26, 27, 28. • position the front log so that the large notch in the underside of the right end of the log fits securely and rests on the sheet metal control cover as shown in figure 29. The front right end of the ...

  • Page 18

    18 20008055 charred oak logset fig. 27 charred oak logset positions. Warning: failure to position the parts in accordance with this diagram or failure to use only parts specifically ap- proved with this heater, may result in property damage or personal injury. Do not alter the logs! Charred oak logse...

  • Page 19: Troubleshooting

    19 20008055 t100 log notch on valve cover 10/15/03 djt valve cover t100 fig. 29 position log so notch fits securely and rests on valve cover. T101 secure front log 10/15/03 djt front log end bar should fit in v-shaped depression in the bark t101 fig. 30 front end of front log should touch grate bar. ...

  • Page 20: Servicing

    20 20008055 servicing repair and replacement work should only be done by a quali- fied service technician. Always shut off the gas supply and make sure the appliance is cool before beginning any service operation. Always check for gas leaks after servicing. Repair parts always include the correct nam...

  • Page 21: Limited 2/20 Year Warranty

    21 20008055 limited 2/20 year warranty for vermont castings ® vent-free gas appliances cfm corporation (company) extends the warranties speci- fied in paragraphs a and b below with respect to its vermont castings decorative gas appliances (the “gas appliance”), including the cfm corporation supplied ...

  • Page 22

    2695 meadowvale blvd. • mississauga, ontario, canada l5n 8a3 800-668-5323 • www.Cfmcorp.Com cfm corporation.