    2261 dv360/580 cover 1/24/00 djt decorative gas appliance model: nv360 nv580 homeowner's installation and operating manual certified design certified 20003565 7/06 rev. 7 please readthis manual before installing and using appliance. Warning: if the information in this manual is not followed ex- actl...

  • Page 2: Table of Contents

    2 nv360/580 series 20003565 table of contents thank you and congratulations on your purchase of a majestic fireplaces fireplace. Please read the installation & operating instructions before using the appliance important: read all instructions and warnings carefully before starting installation. Failu...

  • Page 3

    3 nv360/580 series 20003565 installation & operating instructions this gas appliance should be installed by a qualified installer in accordance with local building codes and with current csa-b149.1 installation codes for gas burning appliances and equipment. If the unit is being installed in a mobile...

  • Page 4

    4 nv360/580 series 20003565 fireplace dimensions fig. 1 fireplace specifications and framing dimensions. A s 3565a nv360 specs 12/6/00 djt k j cl t - rough opening width r d g c rough opening height electrical access rough opening depth recessed nailing flange gas line access m outside air ...

  • Page 5

    5 nv360/580 series 20003565 clearance to combustibles appliances top .......................................................... 0” (0 mm) bottom ..................................................... 0” (0 mm) side ......................................................... 0” (0 mm) back ................

  • Page 6

    6 nv360/580 series 20003565 gas line installation when purging gas line the front glass must be removed. The gas pipeline can be brought in through the right side of the appliance. Knockouts are provided at conve- nient locations to allow for the gas pipe installation and testing of any gas connecti...

  • Page 7

    7 nv360/580 series 20003565 fp297a insta vent free uvhb26 gas supply 7/1/98 1/2" gas supply 1/2" npt x 3/8" flare shut-off valve 3/8" flex line (from valve) fp297a fig. 4 typical gas supply installation. The fireplace valve must not be subjected to any test pressures exceeding 1/2 psi. Isolate or dis...

  • Page 8

    8 nv360/580 series 20003565 install the venting system, flashing and termination note: the nv360 uses a 6" b-vent system. The nv580 uses an 8" b-vent system (refer to accessories, page 23 for adapter). Refer venting installation instructions provided by the b-vent manufacturer. Refer to page 4, figu...

  • Page 9

    9 nv360/580 series 20003565 fp567a 8' venting runs 12/00 venting runs 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 8 9 10 11 12 1 2 3 4 5 6 7 horizontal run (in feet) vertical run (in feet) a a: vertical installations up to 40 feet (12m) in height. Up to an 8 ft. Horizontal vent run can be installed...

  • Page 10: Operating Instructions

    10 nv360/580 series 20003565 operating instructions glass information only glass approved by cfm corporation should be used on this fireplace. • the use of any non-approved replacement glass will void all product warranties. • care must be taken to avoid breakage of the glass. • do not operate applia...

  • Page 11

    11 nv360/580 series 20003565 1. Remove window frame assembly. (refer to page 10) 2. Remove logs from packaging. As with all plastics - these are not toys and should be kept away form children and infants. 3. Place rear log on rear bracket (ensure log is seated properly, leveled and centered to the u...

  • Page 12

    12 nv360/580 series 20003565 inspecting the venting system this appliance venting system was designed and con- structed to develop a positive flow adequate to remove flue gases to the outside atmosphere. Any foreign object in the venting system, except those designed specifically for the venting system...

  • Page 13

    13 nv360/580 series 20003565 is not, turn the unit off and check for causes creating the lack of adequate draft. Do not operate the unit until lack of ad- equate draft has been determined and rectified. First firing upon completing the gas line connection, a small amount of air will be trapped in the...

  • Page 14

    14 nv360/580 series 20003565 24 vac hot 24 vac rtn "on/off" switch nova sit 822 valve honeywell s8600 b ignition module 120 vac rtn 40va transformer 120 vac hot black black black black black black black white white white white white white white white black fp670 nova sit 822 valve wiring dgrm. (w/ h...

  • Page 15

    15 nv360/580 series 20003565 3. Open control access panel. 4. Push in gas control knob slightly and turn clock- wise to "off". Do not force. 5. Close control access panel. 1. Stop! Read the safety information above. 2. Turn off all electrical power to the fireplace. 3. For mn/mp/tn/tp appliances only...

  • Page 16: Troubleshooting

    16 nv360/580 series 20003565 gas supply on • supply line hooked up • shutoff valve open no no no no • lockout has engaged. Wait 60 seconds and try again. • for spark at electrode while depressing piezo - 1/8" gap to pilot hood needed. • all wiring connections • replace piezo ignitor • for air in lin...

  • Page 17: Troubleshooting

    17 nv360/580 series 20003565 troubleshooting sit nova 820 millivolt valve note: before troubleshooting the gas control system, be sure external gas shut off is in the "on" position. Warning: before doing any gas control service work, remove glass front. Symptom 1. Spark ignitor will not light. 2. Pi...

  • Page 18

    18 nv360/580 series 20003565 fuel conversion instructions to convert the dv360/580 units for use with a different gas follow these instructions. Before proceeding, turn control knob on valve to “off” and turn gas supply off. Turn off any electricity that may be going to the appliance. Caution: logs ...

  • Page 19

    19 nv360/580 series 20003565 4. Remove both air shutters from burner pan by remov- ing shutter retaining screw then air shutter. (fig. 26) 5. Install air shutters supplied in kit on burner pan. Replace shutter retaining screw. For conversion to natural gas adjust new air shutters so slots are cov- e...

  • Page 20: Maintenance

    20 nv360/580 series 20003565 maintenance burner and burner compartment it is important to keep the burner and the burner com- partment clean. At least once per year the logs and lava rock/ember material should be removed and the burner compartment vacuumed and wiped out. Remove and replace the logs ...

  • Page 21: Nv360/580

    21 nv360/580 series 20003565 cfm corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. Nv360/580 ref. Description nv360 nv580 1. Log set 20002397 20002071 1a. Log front left b25 e 1b. Log front righ...

  • Page 22: Nv360/580

    22 nv360/580 series 20003565 nv360/580 (continued) ref. Description nv360 nv580 6. Ceramic tile (single) 57803 57803 7. Manifold assembly 10000765 10000765 8a. Ceramic hearth panel (left) 20002274 20002322 8b. Ceramic hearth panel (right) 20002275 20002323 9. Ceramic panel (rear) 20002273 20002319 1...

  • Page 23: Nv360/580

    23 nv360/580 series 20003565 nv360/580 (continued) ref. Description nv360 nv580 44. Piezo ignitor replacement kit - honeywell valve (not shown) 20000062 20000062 45. Vent safety switch 10002013 10002013 46a. Regulator head - natural 10001006 10001006 46b. Regulator head - lp 10001007 10001007 fuel c...

  • Page 24: Accessories

    24 nv360/580 series 20003565 accessories fan kits fk12 fan assembly 1. Open louvre assembly bottom. 2. Install fk12 fan in back of unit between hearth sup- ports. (fig. 32) 3. Secure fan on velcro strips. 4. Power to the fan can be supplied by plugging the supply lead into a conveniently located wal...

  • Page 25

    25 nv360/580 series 20003565 remote controls optional remote control units are available to control different functions of the appliance. Model functions controlled rc1 on/off rc2 on/off and temperature mrc3 on/off and temperature control with a digital display and a programmable 24 hour clock imt w...

  • Page 26

    26 nv360/580 series 20003565.

  • Page 27

    27 nv360/580 series 20003565 © cfm corporation basic warranty cfm corporation (hereinafter referred to collectively as the company) warrants that your new vermont castings or majestic gas fireplace/ stove is free from manufacturing and material defects for a period of one year from the date of purch...

  • Page 28

    2695 meadowvale blvd. • mississauga, ontario, canada l5n 8a3 800-668-5323 • www.Cfmcorp.Com cfm corporation.