Majestic Fireplaces NVC36 Operating Instructions Manual

Manual is about: Decorative Gas Fireplace

Summary of NVC36

  • Page 1

    Decorative gas fireplace installation and homeowners operating instructions please read this manual before installing and using appliance important: read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and...

  • Page 2: Table of Contents

    2 nvc series b-vent 20000194 table of contents thank you and congratulations on your purchase of a cfm corporation fireplace. Please read the installation & operating instructions before using the appliance important: read all instructions and warnings carefully before starting installation. Failure ...

  • Page 3

    3 nvc series b-vent 20000194 installation & operating instructions this gas appliance must be installed by a qualified installer, preferably nfi or wett (canada) certified, in accordance with local building codes and with current csa-b149.1 natural gas and propane installation code. If the unit is bei...

  • Page 4

    4 nvc series b-vent 20000194 installation & operating instructions requirements for the commonwealth of massachusetts all gas fitting and installation of this heater shall only be done by a licensed gas fitter or licensed plumber. For all side wall horizontally vented gas fueled equipment installed in...

  • Page 5

    5 nvc series b-vent 20000194 a d n m n a b s g h j gas line access - 2" dia. Gas line access 2" dia. Finished wall thickness 6" flue rough opening height rough opening width rough opening depth c electrical cable knock-out - 1" dia. E l f k p q r electrical box knock-out - 2" dia. Electrical cable k...

  • Page 6

    6 nvc series b-vent 20000194 clearance to combustibles appliances top .......................................................... 0” (0 mm) bottom ..................................................... 0” (0 mm) side ......................................................... 0” (0 mm) back ...............

  • Page 7

    7 nvc series b-vent 20000194 gas specifications 1. Choose the unit location. 2. Place the unit into position and secure it to the floor with 1 ¹⁄₂ ” (38mm) screws, or nails. The holes to secure the unit to floor are located just behind the access door grille on the left and right side of the unit. 3. F...

  • Page 8

    8 nvc series b-vent 20000194 gas line installation when purging gas line the fornt glass must be removed. Purging gas lines must com- ply with ansi z223.1/nfpa 54 in usa and csa b149.1 in canada. The gas pipeline can be brought in through the right or left side of the appliance, as well as the botto...

  • Page 9

    9 nvc series b-vent 20000194 the fireplace, when installed, must be electrically connected and grounded in accordance with local codes or, in the ab- sence of local codes, with the current csa c22.1 canadian electrical code for usa installations follow the local codes and the national electrical code...

  • Page 10

    10 nvc series b-vent 20000194 fig. 9 firestop/draftstop positions. Ceiling installation fp384 firestop 11/21/96 adapted from igf53 attic installation firestop position when area above ceiling is an attic. Firestop position when area above ceiling is not an attic. (firestop/draftstop appearances may ...

  • Page 11: Operating Instructions

    11 nvc series b-vent 20000194 operating instructions only glass approved by cfm corporation should be used on this fireplace. • the use of any non-approved replacement glass will void all product warranties. • care must be taken to avoid breakage of the glass. • do not operate appliance with glass fr...

  • Page 12

    12 nvc series b-vent 20000194 6. Place the top logs onto the locator notches. Ensure that the logs a re secure. (fig. 12) 7. Place ember material. See "ember material place- ment" section. Nvc36 nvc39 nvc43 front left log bb6 bc5 bd6 front right log bb7 bc6 bd7 rear log be5 bc7 bd8 top left log bb9 ...

  • Page 13

    13 nvc series b-vent 20000194 test chimney draw a "chimney draw" test must be made before the instal- lation is complete. 1. Close all doors and windows in the home and start exhaust fans in the kitchen and bathroom. 2. Light unit and operate for 5 minutes. 3. Hold an ignited match, cigarette, or sm...

  • Page 14

    14 nvc series b-vent 20000194 3. Open control access panel. 4. Push in gas control knob slightly and turn clock- wise to "off". Do not force. 5. Close control access panel. 1. Stop! Read the safety information above. 2. Turn off all electrical power to the fireplace. 3. For mn/mp/tn/tp appliances onl...

  • Page 15

    15 nvc series b-vent 20000194 vent safety switch this fireplace incorporates the use of a vent safety shut-off switch. The sensor and wiring are factory installed and should not be removed or altered during installation. In the event of total flue blockage the system will detect the increased heat bui...

  • Page 16: Troubleshooting

    16 nvc series b-vent 20000194 troubleshooting fp649 turn gas supply off turn on/off switch to call for heat. No no no no no no no spark across ignitor sensor gap power to module (24v nominal) yes yes yes yes yes yes yes turn gas on pilot burner lights? Spark stops when pilot is lit? Main burner ligh...

  • Page 17: Honeywell Vs8421

    17 nvc series b-vent 20000194 remove glass door before service work honeywell vs8421 start check gas supply on pilot lights with piezo ignitor • lockout has engaged. Wait 60 seconds and try again. • for spark at electrode while depressing piezo 1/8" gap to pilot hood needed. • all wiring connections...

  • Page 18: Troubleshooting

    18 nvc series b-vent 20000194 troubleshooting fp396 gas supply on supply line hooked up shutoff valve open no no no no lockout has engaged. Wait 60 seconds and try again. Piezo nut tight for good ground. For spark at electrode while depressing piezo (red button) - 1/8" gap to pilot hood needed. All ...

  • Page 19: Maintenance

    19 nvc series b-vent 20000194 cleaning the standing pilot control system the burner and control system consists of • burner tube • gas orifice • pilot assembly • thermopile • millivolt gas valve most of these components may require only an oc- casional checkup and cleaning and some may require adjust...

  • Page 20: Nvc36/39/43

    20 nvc series b-vent 20000194 fp772a replacement parts nvc 8/25/98 31 28 29 26 6a/b 4a/b 5 36 35 34 1a 1b 1c 1d 1e nvc43 logs 1 27 37 2 3 1a 1b nvc36 1d 1e 1c 1e 1c 1a 1b 1d nvc39 1 18 25 17a/b 22 19 ...

  • Page 21: Nvc36/39/43

    21 nvc series b-vent 20000194 nvc36/39/43 (continued) ref. Description nvc36 nvc39 nvc43 4a. Burner housing w/tile-nat 10000027 10000033 10000029 4b. Burner housing w/tile-lp 10000028 10000694 10000030 5. Ceramic tile (single) 57803 57803 57803 6a. Orifice front burner-nat. See rating plate 6b. Orific...

  • Page 22: Nvc36/39/43

    22 nvc series b-vent 20000194 nvc36/39/43 (continued) ref. Description nvc36 nvc39 nvc43 40a. Valve - honeywell vs8421 - nat. 10001782 10001782 10001782 40b. Valve - honeywell vs8421 - lp 10001759 10001759 10001759 41. Vent safety switch 10002013 10002013 10002013.

  • Page 23: Optional Accessories

    23 nvc series b-vent 20000194 optional accessories fan kits fk12 fan assembly 1. Open louvre assembly bottom. 2. Install fk12 fan in back of unit between hearth sup- ports. 3. Secure fan on velcro strips. 4. Power to the fan can be supplied by plugging the supply lead into a conveniently located wal...

  • Page 24

    24 nvc series b-vent 20000194 remote controls optional remote control units are available to control different functions of the appliance. Model function(s) controlled rc1 on/off rc2 on/off and temperature imtfk wall mounted thermostat control ceramic refractory panels ceramic refractory panels are ...

  • Page 25

    25 nvc series b-vent 20000194 fp1195 arched door front 2/27/02 djt fp1196 fig. 28 arched door front in place. Eb-1 electrical box standard on electronically controlled models, the eb-1 is also available for other fireplaces. Installation should be completed by a qualified service person. Decorative fr...

  • Page 26

    26 nvc series b-vent 20000194.

  • Page 27

    27 nvc series b-vent 20000194 basic warranty cfm corporation (hereinafter referred to collectively as the company) warrants that your new vermont castings or majestic gas fireplace/ stove is free from manufacturing and material defects for a period of one year from the date of purchase, subject to t...

  • Page 28

    Efficiency ratings model energuide ratings fireplace efficiency (%) nvc36rn 29.4 nvc36rp 29.4 nvc36rfn 29.4 nvc36rfp 29.4 nvc36en 28.5 nvc36ep 28.5 nvc39rn 26.4 nvc39rp 26.4 nvc39rfn 26.4 nvc39rfp 26.4 nvc39en 25.6 nvc39ep 25.6 nvc43rn 27.9 nvc43rp 27.9 nvc43rfn 27.9 nvc43rfp 27.9 nvc43en 27.1 nvc43ep...