    1 rfsuv34 vent-free heater installer: do not discard this manual leave for homeowner. Please read this manual before install- ing and using appliance. Important: read all instruc- tions and warnings carefully before starting installation. Failure to follow these instruc- tions may result in a possib...

  • Page 2: Table of

    2 rfsuv34 vent-free heater table of contents general information . . . . . . . . . . . . . . . . . 3 dimensions and framing . . . . . . . . . . . . . 4 safety devices . . . . . . . . . . . . . . . . . . . . . 5 clearances to combustibles . . . . . . . . . . . 5 gas supply pressure . . . . . . . . . ...

  • Page 3: General

    3 rfsuv34 vent-free heater general information for safe installation and operation of your pyromaster vent-free room heater please note the following: 1. This heater gives off high temperatures and should be located out of high traffic areas and away from furniture and draperies. 2. Children and adu...

  • Page 4

    4 rfsuv34 vent-free heater rfsuv34 dimensions model rfsuv34 a 31 1/2" 800mm b 19 5/8" 498mm c 26 1/8" 664mm d 21 1/2" 546mm e 10" 254mm f 18 3/4" 476mm g 3" 76mm h 1 1/2" 38mm j 22 1/4" 565mm k 20 5/8" 524mm l 19 3/18" 487mm m 7 3/4" 197mm n 19 1/2" 495mm p 22 1/4" 565mm ➤ ➤ ➤ ➤ c b ➤ ➤ n ➤ ➤ c ➤ ➤ ...

  • Page 5

    5 rfsuv34 vent-free heater safety devices adequate combustion and ventilation air must be provided. The flow of combustion and ventilation air must not be obstructed. Provide adequate clearances around the air opening into the combustion chamber and ad- equate accessibility clearance for servicing a...

  • Page 6: Installation

    6 rfsuv34 vent-free heater it will be easier to install the fan before connecting the gas line to the fireplace. 1. Open front access door panel by pulling forward on handle. 2. Fig. 3. Install the fan through the opening at the back of the pedestal, with the outlet pointed up and the fan mounting b...

  • Page 7

    7 rfsuv34 vent-free heater fig. 3 wall receptacle. 4. Slide the heater in place with the fan installed, gently slide or lift the heater to the desired location. 5. Level and secure the heater make sure heater is level. Shimming may be required. 6. Window frame removal (fig. 4) 1. Shut off gas. (see ...

  • Page 8: Operating Instructions

    8 rfsuv34 vent-free heater first firing upon completing your gas line connection, a small amount of air will be in the lines. When first lighting unit with pilot light, it will take a few minutes to purge this air. Once the purging is complete, the pilot and burner will light and operate as indicate...

  • Page 9: Lighting Instructions

    9 rfsuv34 vent-free heater 4. Push in gas control knob slightly and turn clockwise to "off". Do not force. 5. Close control access panel. 10. Push the control knob all the way in and hold. Immediately light the pilot by repeatedly depressing the piezo spark ignitor until a flame appears. Continue to...

  • Page 10: Troubleshooting -

    10 rfsuv34 vent-free heater troubleshooting - • gas supply on • supply line hooked up • shutoff valve open no no no no • lockout has engaged. Wait 60 seconds and try again. • for spark at electrode while depressing piezo — 1/8" gap to pilot hood needed. • all wiring connections • replace piezo ignit...

  • Page 11: Maintenance

    11 rfsuv34 vent-free heater maintenance keep the control compartment, logs and burner area surrounding the logs clean by vacuuming or brushing at least twice a year. The logs can get very hot — handle only when cool. Always turn off gas to the pilot before cleaning. For relighting, refer to lighting...

  • Page 12: Accessories

    12 rfsuv34 vent-free heater caution: this heater is a highly engineered system, and, as such, must be operated only with majestic approved components. If you use an unapproved component to make any modifica- tions, you may create a possible fire hazard and will void the majestic warranty. In additio...

  • Page 13: Rfsuv Replacement Parts

    13 rfsuv34 vent-free heater rfsuv replacement parts 8 9 6 4a/b 5 7 2 15 11a/b 24 17 18 3 23 16 26 27 19 25 lo h i pilot adj pilot on off 14 a/b 12 22 21 #1 complete log set - rfsuv34 kr11 kr7 kr10 kr12 kr8 kr9.

  • Page 14

    14 rfsuv34 vent-free heater replacement parts list description rfsuv34 1 log set complete 10001763 1a. Log ember front kr7 1b. Log front left kr8 1c. Log front right kr9 1d. Log rear kr10 1e. Log top left kr11 1f. Log top right kr12 2. Lava rock burner (package) 57897 3. Burner housing assembly w/ti...

  • Page 15