Majestic Super B-Vent Series BV4536 Installation & Operating Instructions Manual

Manual is about: Natural Vent Gas Fireplace

Summary of Super B-Vent Series BV4536

  • Page 1

    Super b-vent series natural vent gas fireplace installation & operating instructions warning if the information in these instructions is not followed exactly, a fire or explo- sion may result causing property dam- age, personal injury or loss of life. — do not store or use gasoline or other flam- ma...

  • Page 2

    41d2001 2 bv4536, bv5142 natural vent gas fireplace table of contents thank you and congratulations on your purchase of an mhsc fireplace please read the installation and operation instructions before using the appliance! Important: read all instructions and warnings carefully before starting instal...

  • Page 3

    41d2001 3 bv4536, bv5142 natural vent gas fireplace important safety information installer please leave these instructions with the appliance. Owner please retain these instructions for future reference. W arning • read this owner’s manual carefully and completely before trying to assemble, operate,...

  • Page 4

    41d2001 4 bv4536, bv5142 natural vent gas fireplace 14. Do not use any solid fuels (wood, coal, paper, card- board, etc.) in this fireplace. Use only the gas type indicated on rating plate. 15. This appliance, when installed, must be electrically grounded in accordance with local codes or in the abs...

  • Page 5

    41d2001 5 bv4536, bv5142 natural vent gas fireplace pre-installation information high elevations input ratings are shown in btu per hour and are certified without deration for elevations up to 4,500 feet (1,370 m) above sea level. For elevations above 4,500 feet (1,370 m) in usa, installation must b...

  • Page 6

    41d2001 6 bv4536, bv5142 natural vent gas fireplace fireplace dimensions figure 1 - bv4536 dimensions 45” 36” 22 56o ” 33 56o ” 23 56o ” 11 6m ” 41” 26” 7 56o ” 44 56 ” 2 6 ” 7 56m ” 412001 bv4536 dims 51” 42” 25 56o ” 39 56o ” 23 56o ” 11 6m ” 41” 26” 7 56o ” 44 56 ” 2 6 ” 7 56m ” 412001 bv5142 dim...

  • Page 7

    41d2001 7 bv4536, bv5142 natural vent gas fireplace 45” min. A a e min. E min. A 412001 vb4536 5142 framing dims 1/09 a b min. C min. D min. Fireplace framing firebox framing can be built before or after the appliance is set in place. Construct firebox framing fol- lowing figure 3 and the chart belo...

  • Page 8

    41d2001 8 bv4536, bv5142 natural vent gas fireplace pre-installation information fireplace location plan for the installation of your appliance. This includes determining where the unit is to be installed, the vent configuration to be used, framing and finishing details, and whether any optional acc...

  • Page 9

    41d2001 9 bv4536, bv5142 natural vent gas fireplace clearances clearances to combustibles w arning follow these instructions carefully to ensure safe installation. Failure to follow instructions exactly can create a fire hazard. The appliance cannot be installed on a carpet, tile or other combustibl...

  • Page 10

    41d2001 10 bv4536, bv5142 natural vent gas fireplace installation information finishing material measure fireplace dimensions and ve- rigy framing methods and wall covering details before framing constructions be- gins. Only noncombustible materials (i.E. Brick, tile, slate, steel or other materials...

  • Page 11

    41d2001 11 bv4536, bv5142 natural vent gas fireplace vent installation w arning the following venting instructions are provided as a general guideline. Always check with pipe manufacturer for venting requirements. Installation precautions consult local building codes before beginning the installatio...

  • Page 12

    41d2001 12 bv4536, bv5142 natural vent gas fireplace vent installation w arning never use more than two (2) 45° elbows. When using adjustable elbows, never exceed 45°. Vertical venting with two (2) 45° elbows a b fp1294 vert vent w elbows figure 8 - vertical venting with two (2) 45° elbows fp2194 no...

  • Page 13

    41d2001 13 bv4536, bv5142 natural vent gas fireplace vent installation firestop installation a ceiling firestop must be installed if the vent passes through a ceiling. Refer to the instructions from the pipe manufacturer. To position firestop refer to figures 9 and 10 . Only one (1) firestop require...

  • Page 14

    41d2001 14 bv4536, bv5142 natural vent gas fireplace vent installation vertical termination major building codes specify a minimum vent height above the rooftop depending on the pitch of the roof. Refer to figure 12 for minimum heights, provided the termination cap is at least 8’ from a vertical wal...

  • Page 15

    41d2001 15 bv4536, bv5142 natural vent gas fireplace outside air kit w arning to operate this appliance, the outside air kit must be installed and operational. Operation without the outside air kit may result in high temperature on combus- tible materials and possible spillage of combustion product ...

  • Page 16

    41d2001 16 bv4536, bv5142 natural vent gas fireplace fireplace installation check gas type use proper gas type for the fireplace you are installing. If you have conflicting gas types, do not install fireplace. See dealer where you purchased the fireplace for proper fireplace for your gas type. Insta...

  • Page 17

    41d2001 17 bv4536, bv5142 natural vent gas fireplace fireplace installation w arning only persons licensed to work with gas piping may make the necessary gas connections to this appliance. Caution a manual shut-off valve must be installed upstream of the appliance. Union tee and plugged 1/8” npt pre...

  • Page 18

    41d2001 18 bv4536, bv5142 natural vent gas fireplace checking gas pressure 1. Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is different from the fireplace, stop! Do not install the appliance. Contact your dealer immediately. 2. To ease ...

  • Page 19

    41d2001 19 bv4536, bv5142 natural vent gas fireplace electrical installation verify proper operation after servicing. Remote wall mounted switch a remote wall switch and up to fifteen (15) feet of 18 ga. Wire may be used with this appliance. Attach the wall switch in a junction box at the desired lo...

  • Page 20

    41d2001 20 bv4536, bv5142 natural vent gas fireplace electrical installation electronic pilot ignition wiring w arning do not connect 110-120v ac to the re- mote wall switch. The appliance will malfunction or destroyed. &0 electronicignitionwiring figure 18 - electronic ignition system wiring diagra...

  • Page 21

    41d2001 21 bv4536, bv5142 natural vent gas fireplace final installation w arning do not sprinkle the lava rock or ember chunks on top of the burner. This may cause potential sooting, glass breakage and a fire hazard. Wall finishing combustible materials: materials made of, or surfaced with wood, com...

  • Page 22

    41d2001 22 bv4536, bv5142 natural vent gas fireplace final installation w arning glass doors must be installed on all propane/lp units and operated in the closed position to eliminate any potential for soot spillage into the room. When installing a natural gas unit with glass door option, the unit m...

  • Page 23

    41d2001 23 bv4536, bv5142 natural vent gas fireplace final installation damper operation 1. When damper lever is all the way to the left and locked into position, the damper system is closed. Figure 22 2. Pull damper lever forward and unlock from closed position by swinging damper lever to the right...

  • Page 24

    41d2001 24 bv4536, bv5142 natural vent gas fireplace operating instructions before lighting the fireplace • read the important safety information section at the beginning of this manual. • before lighting, check the fireplace for possible gas leaks. • before lighting, check for possible obstructions...

  • Page 25

    41d2001 25 bv4536, bv5142 natural vent gas fireplace operating instructions for your safety read before lighting w arning if you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal in- jury or loss of life. A. This appliance is equipped with a p...

  • Page 26: To Turn Off Gas

    41d2001 26 bv4536, bv5142 natural vent gas fireplace operating instructions lighting instructions millivolt 1. Stop! Read the safety information before pro- ceeding. 2. Open access door on left side of floor to reveal gas valve. Locate rs-off-on rocker switch on left side inner chamber. 3. Turn rs-o...

  • Page 27: Lighting Electronic Ign

    41d2001 27 bv4536, bv5142 natural vent gas fireplace operating instructions for your safety read before lighting w arning if you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal in- jury or loss of life. A. This appliance is equipped with an ...

  • Page 28

    41d2001 28 bv4536, bv5142 natural vent gas fireplace lg637 bv4536 log flames cleaning and maintenance w arning turn off gas before servicing fireplace. It is recommended that a qualified service technician perform these check-ups at the beginning of each heating season. Burner, pilot and control com...

  • Page 29

    41d2001 29 bv4536, bv5142 natural vent gas fireplace cleaning and maintenance vent system the fireplace and venting system should be inspected before initial use and at least annually by a quali- fied field service person. Inspect the external vent cap on a regular basis to make sure that no debris ...

  • Page 30

    41d2001 30 bv4536, bv5142 natural vent gas fireplace troubleshooting standing pilot ignition symptom 1. Spark igniter will not light pi- lot after repeat- ed triggering of piezo. 2. Pilot will not stay lit after carefully fol- lowing lighting instructions. 3. Pilot burning, valve knob tuned to “on”,...

  • Page 31

    41d2001 31 bv4536, bv5142 natural vent gas fireplace troubleshooting electronic ignition start 1. Turn gas supply off. 2. Turn on/off switch to “on” power to module (24v normal) yes is there a spark across ignitor sensor gap? Yes turn on gas. Does pilot burner light? Yes does spark stop when pilot i...

  • Page 32

    41d2001 32 bv4536, bv5142 natural vent gas fireplace troubleshooting general troubleshooting symptom 1. Glass soots. 2. Poor draft due to venting. 3. Poor draft due to termination cap. 4. Poor draft due to ext. Environ- ment. 5. Poor draft due to internal envi- ronment. 6. Unit shuts down prematurel...

  • Page 33

    41d2001 33 bv4536, bv5142 natural vent gas fireplace replacement parts 412001 bv4536 5142 log parts 1 2 3 4 5 6 ref. Description bv4536 bv5142 1. Rear log 32d2118 32d2118 2. Front left log 32d2117 32d2117 3. Front right log 32d2116 32d2116 4. Top middle log 32d2114 32d2114 5. Top right log 32d2113 3...

  • Page 34

    41d2001 34 bv4536, bv5142 natural vent gas fireplace replacement parts engine components 1 2 3 4 5 6 7 8 9 10 11 12 412001 bv4536 5142 parts 1/09 ref. Description qty. Bv4536nv bv4536pv bv5142nv bv5142pv 1. Gas valve assembly 1 26d0506 26d0507 26d0506 26d0507 2. Pilot assembly 1 41d0327 41d0328 41d0...

  • Page 35

    41d2001 35 bv4536, bv5142 natural vent gas fireplace limited lifetime warranty policy lifetime warranty the following components are warranted for life to the original owner, subject to proof of purchase; firebox, combus- tion chamber, heat exchanger, grate and stainless steel burners. Five year war...

  • Page 36

    Mhsc 149 cleveland drive • paris, kentucky 40361 www.Mhsc.Com february 2009 41d2001 • rev. 6.