Majestic VF Installation And Operating Instructions Manual

Manual is about: Vent-free Fireboxes

Summary of VF

  • Page 1

    Vent-free fireboxes models: vf, vfr 710530 gcuf cover if the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. – do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or an...

  • Page 2

    71d0531 vf/vfr vent-free fireboxes contents please read the installation & operating instructions before using appliance. Thank you and congratulations on your purchase of a majestic vent free firebox. Important: read all instructions and warnings carefully before starting installation. Failure to f...

  • Page 3

    3 71d0531 vf/vfr vent-free fireboxes 13. Correct installation of the ceramic fiber logs, proper location of the heater, and annual cleaning are neces- sary to avoid potential problems with sooting. Sooting, resulting from improper installation or operation, can settle on surfaces outside the firepla...

  • Page 4

    71d0531 4 vf/vfr vent-free fireboxes important safety information continued from page 3 the initial break-in operation should last two to three hours with the burner at the highest setting. Provide maximum ventilation by opening windows or doors to allow odors to dissipate. Any odors remaining after...

  • Page 5

    5 71d0531 vf/vfr vent-free fireboxes general installation information the vf-tb and vf-r series are vent-free fireboxes. They feature a self contained heat-circulating system. These units also feature a -in1, flexible-face system, sold as an accessory, that converts the circulating system into a rad...

  • Page 6

    71d0531 6 vf/vfr vent-free fireboxes firebox dimensions 2 56o ” b 2 56o ” a rough opening height d f c rough opening depth m - rough opening width 1/2” - 5/8” o q p p r 710530 gcuf dims i 1 56m ” 6” 1 6qe ” 5 (6qe ” n 21 6m ” e h j l g k ref. Vf/vfr32c vf/vfr36c vf/vfr42c a 37" 41" 47" b 3" 36" 4" c...

  • Page 7

    7 71d0531 vf/vfr vent-free fireboxes hearth dimensions and firebox location a b c d e fp2901 hearth dims ref. Vf/vfr32c vf/vfr36c vf/vfr42c a 9 m\, " 34" 40" b 13 z\v " 15 c\v " 15 c\v " c 3 c\, " 7 c\, " 33 c\, " d 1 m\, " 1 m\, " 1 m\, " e 18" 17 b\, " 17 b\, " figure 2 - minimum hearth dimensions...

  • Page 8

    71d0531 8 vf/vfr vent-free fireboxes ensure that minimum clearances shown in figures 4 through 8 are maintained. Left and right clearances are determined when facing the front of the firebox. Follow these instructions carefully to ensure safe instal- lation. Failure to follow these requirements may ...

  • Page 9

    9 71d0531 vf/vfr vent-free fireboxes fp2688 min floor combustible 5" minimum combustible material fp688 figure 7 - minimum clearance above combustible flooring minimum clearances and framing 14” minimum fp2689 min floor clear noncomb can be less than 5" noncombustible material fp689 figure 8 - minim...

  • Page 10

    71d0531 10 vf/vfr vent-free fireboxes fireplace and canopy installation when finishing a custom cabinet, mantel, or other built-in enclosure, the opening size to accommodate the fireplace with trim installed is as follows: figure 10 - custom cabinet a b fp2694 custom cabinet vf/vfr32c vf/vfr36c vf/v...

  • Page 11

    11 71d0531 vf/vfr vent-free fireboxes gas line installation consult all local codes. All gas piping must be installed to comply with local codes, or in the absence of local codes, with the latest edition of the national fuel gas code ansi z3.1/nfpa54. Remove the baseplate for ease of gas line instal...

  • Page 12

    71d0531 1 vf/vfr vent-free fireboxes combustion air combustion air 1. Locate combustion air assembly at an exterior location which is not likely to be accidentally blocked in any man- ner. Locate assembly a min. Of 1" above the snow line to prevent blockage by snow accumulation. . Never mount the co...

  • Page 13

    13 71d0531 vf/vfr vent-free fireboxes combustion air w arning do not remove the cover if the outside air will not be connected. The use of outside air for combustion is optional unless required by building codes. It is only necessary to supply outside combustion air to one side of the fireplace. Use...

  • Page 14

    71d0531 14 vf/vfr vent-free fireboxes combustion air 7. If the duct is the insulated type, push the insulation back from one end of the duct approximately ". Figure 19 8. Slip the exposed end of the duct over the starting collar on the fireplace . 9. Using the sheet metal screws provided, secure the...

  • Page 15

    15 71d0531 vf/vfr vent-free fireboxes optional equipment forced air kit (blotmc) if you are installing the forced air kit on vf-tb or vf-r models, see the installation instructions provided with the kit for electrical wiring requirements, or the blower installation section. The firebox must be conne...

  • Page 16

    71d0531 16 vf/vfr vent-free fireboxes replacement parts 5 1 2 4 7 6 4 3 710530 gcuf parts firebox components ref. Description qty. Vf/vfr32c vf/vfr36c vf/vfr42c 1. Canopy 1 71d003 71d0500 71d1000 . Screen panel 61d0001 61d0001 61d0003 3. Screen rod 6d0138 6d013 6d0133 4. Black louver 6 6d0695 6d0697...

  • Page 17

    17 71d0531 vf/vfr vent-free fireboxes.

  • Page 18

    71d0531 18 vf/vfr vent-free fireboxes.

  • Page 19

    19 71d0531 vf/vfr vent-free fireboxes limited lifetime warranty policy the following components are warranted for life to the original owner, subject of proof of purchase: firebox, combustion chamber, heat exchanger, grate, and stainless steel burners. Five year warranty the following components are...

  • Page 20

    Mhsc 149 cleveland drive • paris, kentucky 40361 www.Mhsc.Com.