MAKELSAN 10K User Manual

Summary of 10K

  • Page 1

    -1- makelsan ups 1 brief introduction 1.1 prolegomenon the product is designed specially aiming at the requirement of mini and micro level computer with exquisite quality and excellent function, easy to operate. With the development of customer office automatism and computerism, considering the bulk...

  • Page 2: Configuration and Function

    -2- makelsan ups 2 configuration and function 2.1 front panel configuration and function 1) welcome screen welcome to 2) display of system status _pro ac: in bat: ok note: ac indicates utility; bat indicates battery; ac: in indicates utility power is normal; ac: loss indicates utility power is abnor...

  • Page 3

    -3- makelsan ups 3) display of input voltage value input voltage 220v 2/8 4) display of output voltage value output voltage 220v 3/8 5) display of input frequency value input frequency 50hz 4/8 6) display of output frequency value output frequency 50hz 5/8 7) display of battery voltage value battery...

  • Page 4

    -4- makelsan ups 2.2 appearance 8 lcd cycle display switch button: digital signal display items switch button. 9 ups switch button: ups general switch button. (1) turn on ups inverter by pressing the "on" key. Ups convert to ups inverter power output 20s later, ups pure ac output power is supplied b...

  • Page 5

    -5- makelsan ups 11 wiring inlet/outlet hole: wiring inlet/outlet hole of input, output and battery pack. 12 db-9 communication interface receptacle standard communication interface between ups and computer. 13 power switch: power switch controls input, output and battery power switch at the same ti...

  • Page 6: 3   Placement Notes

    -6- makelsan ups movement handling 3 placement notes 3.1 transit or move 1. Please dismantle all barge connection firstly. (first turn off before performing) 2. Place lightly and carefully, forbid to hit. 3. Please do not move ups inverted. 3.2 placement 1. Do not place the ups on the slope or scrag...

  • Page 7

    -7- makelsan ups 3. Do not install ups under sunlight, drain and damp place. (figure 6, 7) 4. Please keep away from fire source and high temperature to avoid over-high temperature. (figure 8) 5. Do not lay goods on the ups. (figure 9) 6. Do not install ups in the place where contains caustic gas. (f...

  • Page 8: 4   Installation

    -8- makelsan ups 7. Running environment temperature: installation 4 installation 4.1 input 1. Prohibit using general household socket, because the max. Current of general socket is 15a, the socket may be burned down because of overload..

  • Page 9

    -9- makelsan ups 2. Please connect ups input terminal to utility power in nearby switchboard. Figure 11. 3. Position and way of connect (1) remove two screws with "+" screw-driver (figure 12) (2) open the back panel and inspect the wiring terminal below the power switch. (figure 13) 4. Relock the sp...

  • Page 10

    -10- makelsan ups installation.

  • Page 11

    -11- makelsan ups installation.

  • Page 12

    -12- makelsan ups installation 6. Please connect power correctly simple identification way to power polarity: (1) live (l): there is 220v relative to other two holes. (2) neutral (n): there is 220v relative to the live, there is 0.5-2v relative to the ground. (load current circulate through neutral)...

  • Page 13

    -13- makelsan ups installation 13. Please follow the electrician law when installation. 14. Avoid using the same switch with other equipment when connect to switchboard, try to connect cable to utility terminal. Figure 14. 15. In 3 4w system, please respectively measure the voltage between r/n, s/ n...

  • Page 14

    -14- makelsan ups installation 4.2 output 1. Please refer to output installation principle when installation. 2. Position and way of connection, refer to figure 15. 3. Output power cable is designed according to load current, do not use over-thin cable. Please refer to table 2 4. Avoid short-circuit...

  • Page 15

    -15- makelsan ups installation 6. The ground to this unit only acts as reference point, if the ground isn't good, that may cause disturbance and false datum management, and affect ups and computer, please ask professional personnel for handling immediately. 7. User offers a good grounding system. 8....

  • Page 16: 5   Operation Process

    -16- makelsan ups operation process 5 operation process 5.1 prepare before start-up. To make ups normally and correctly run, please confirm the following items. (refer to figure 2) 1. Verify power switch on back panel is on the "off" position. 2. Verify the installation position again. (figure 4 to ...

  • Page 17

    -17- makelsan ups 2. Press the "on" button on front panel. As right figure. The input indicator and the bypass indi- cator are solid on. Lcd display is lit on. Output is utility pow- ered via bypass. 3. After 20s, input indicator light on front panel is lit on, bypass indi- cator is off, and output ...

  • Page 18

    -18- makelsan ups matically stop 90s later. Ups will sound alarm every 1s again when battery power is to be exhausted. 5. Utility indicator will be lit on when ups input power source is resumed. Press the lcd display cycle switch button to switch items displayed, inspect if the display value is norm...

  • Page 19: 6   Status Handling

    -19- makelsan ups status handling 6 status handling 6.1 symbol signification note: if indicator light flash, the flash period is synchronal with that of buzzer sounds 1. Panel indicator status is as the right figure: (1) ups running status: utility is normal, ups runs normally and ups is used under ...

  • Page 20

    -20- makelsan ups 2. Panel indicator status is as the right figure (1) ups running status: utility is normal, ups runs normally and battery capacity is above 90%. (2) handling way: needn't handling. 3. Panel indicator status is as the right figure: (1) ups running status: utility supplies power of 2...

  • Page 21

    -21- makelsan ups *note: the material parameters indicated vary with the machine type. 5. Panel indicator status is as the right figure: (1) ups running status: utility power is normal and it con- verts to utility mode. Ups don't start up if didn't press the "on" button down on the ups panel. (2) ha...

  • Page 22

    -22- makelsan ups 7. Panel indicator status is as the right figure: (1) ups running status: utility power is normal, ups runs ab- normally and convert to be utility powered. (2) handling way: please refer to flow chart 22 of status handling. 8. Panel indicator status is as the right figure: (1) ups ...

  • Page 23

    -23- makelsan ups 9. Panel indicator status is as right figure: (1) ups running status: utility power is disconnected and ups is battery powered. Buzzer beeps once every one second when the battery power will be exhausted. (2) handling way: ups will be shut down, please save files and close your com...

  • Page 24: 7   Movement Handling

    -24- makelsan ups movement handling 7 movement handling 7.1 ups system configuration block figure: figure 23 7.2 ups's running way when ups runs normally when ups runs normally, after high-frequency harmonic noise in utility power is filtered by the filter, on one hand utility power charges battery ...

  • Page 25

    -25- makelsan ups 7.3 ups's running way when utility disconnected as figure 25, when utility disconnected, power is battery supplied to the inverter then is sostenuto transmitted to user equipment for using via the static switch and the filter to avoid power disturbance to load. 7.4ups's running way...

  • Page 26

    -26- makelsan ups 7.5 battery and charge 1. When power switch on back panel is on the position of "on", the batteries can automatically be charged and the charger can charge 90% of the battery capacity in 10 hours. 2. The time that battery supplies power has relation with using rate of load, please ...

  • Page 27: 8   Communication Interface

    -27- makelsan ups 7.6 daily maintenance 1. Ups should be cleaned and maintained termly, avoid any dust to ensure machine life. 2. Please clean ups lightly with soft cloth, don't use grit for instead for ever. 3. Termly inspect all kinds of connection every month and avoid any hit, looseness or humid...

  • Page 28

    -28- makelsan ups 8.3 the computer interface of ups offer detailed datum and is suit to net route, workstation, monitoring system, pc, etc. Computer interface: it can sostenuto transmit datum through rs232 communication series port and computer. The datum that ups offers includes input voltage value...

  • Page 29: Specification

    -29- makelsan ups specification capacity (va) 1k 2k 3k 5k 6.25k 10k 12.5k ac input voltage 160~310vac (avr) frequency 50(60)hz 5% phase single max.Current 6a 10a 14a 24a 34a 45a 56a ac output voltage 220v frequency 50(60)hz voltage stability 1% frequency stability 0.5% (disconnection) wave form spwm...

  • Page 30

    -30- makelsan ups capacity (va) 1k 2k 3k 5k 6.25k 10k 12.5k internal protection equipment lcd panel battery ups automatically shutdowns when battery is low power level there is no fuse switch protection overload when load reaches 110~150% of rating, transfer to bypass after 3s, recover auto. Over-te...

  • Page 31: 10 Shipping List

    -31- makelsan ups order consent number 1 ups 1 2 ups use manual 1 3 intelligent monitoring software 1 4 computer port cable 1 shipping list 10 shipping list.

  • Page 32

    -32- makelsan ups shipping list.

  • Page 33

    -33- makelsan ups shipping list.

  • Page 34

    -34- makelsan ups shipping list.

  • Page 35: Content

    -35- makelsan ups content 1 brief introduction ........................................... 1 2 configuration and function ...................... 2 3 placement notes ................................................ 6 4 installation .......................................................... 8 5 operat...