Panel Features
Rear Panel Features
4
7
1
5
6
8
3
2
8
4
7
5
6
9
1. IEC POWER CONNECTOR
Standard IEC power receptacle for connect-
ing AC Mains supply. Use only the supplied cable.
2. BANK “B” PRIMARY FUSE
AC fuse protects the bank B primary
power supply.
3. BANK “A” PRIMARY FUSE
AC fuse protects the bank A primary
power supply.
4. RS-485 IN CONNECTIONS
Removable Euro connectors for terminat-
ing data lines from COntrolMatrix field devices. NOTE: There are no active
electronics or supervision for these connections.
5. STATION CONNECTIONS
Removable Euro connectors for terminating
PCU Series paging stations. Each supply circuit is bi-polar (+15VDC, GND,
-15VDC) and requires a 3-conductor cable suitable for the output load.
There are four supervised circuits with two output connections for a total of
8 PCU Series stations.
6. CONTROL PANEL CONNECTIONS
Removable Euro connectors for ter-
minating ControlMatrix remote control panels. Each supply circuit is sin-
gle-ended (+12VDC, GND) and requires a 2-conductor cable suitable for
the output load. There is one supervised circuit distributed to 4 connec-
tions. Maximum load is 10 ControlMatrix remote panels.
7. RS-485 OUT CONNECTION
Removable Euro connector for distributing
data lines from ControlMatrix field devices to MediaMatrix head-end.
Shield pin is at chassis potential.
8. FAULT CONTACT CONNECTOR
Removable Euro connector for termi-
nating an external fault alarm or control circuit. This connector is internal-
ly coupled to a relay and provides a Form “C” connection (SPDT). The
contacts are rated for 600mA, 125 VAC; 2A at 30VDC.
9. REDUNDANT MODE SWITCH
Two-position switch for configuring
redundant or dual-mode operation. The PCU 2100 is in Redundant Mode
when the switch is in the DOWN position (default mode), and in Dual Mode
when the switch is in the UP position. A front panel LED indicates the
active mode.